NASA’s Developments in Cryogenic Fluid Management Technology

Abstract

NASA has been pursuing the development and demonstration of enabling and enhancing technologies for Cryogenic Fluid Management (CFM) in collaboration with the US industry. NASA’s vision for current and future space exploration requires high-performance chemical and nuclear propulsion solutions that utilize cryogens. The Agency will use cryogenic fluids for Earth-to-orbit transportation, human missions to the Moon and Mars, planetary exploration, and in-situ resource utilization (ISRU) production. All these architectures will require state-of-the-art long-duration storage on the surface and in-space transfer for refueling. This paper focuses on key CFM technology developments completed or ongoing by the Cryogenic Fluid Management Portfolio Office within NASA’s Space Technology Mission Directorate. The CFM Portfolio Office, partnered with US aerospace industry, has invested in CFM technology ground and flight demonstrations, focused on maturing CFM hardware and operations for Artemis and Moon to Mars activities. These demonstrations additionally provide NASA with data to inform numerical modeling activities for verification and validation of design tools and approaches for future missions. This paper includes discussion on remaining high-priority open CFM technology gaps for Mar-forward architectures and initiatives for closure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lauren M Ameen, R Jeremy Kenny, Wesley L Johnson, Kathryn L Henkel. NASA’s Developments in Cryogenic Fluid Management Technology. https://ntrs.nasa.gov/citations/20240004242

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation & Verification of CFD Models for Cryogenic Fluid Management of Propellant Tanks in Space

This article describes the need and the strategy for CFD model development, validation, and verification for Cryogenic Fluid Management (CFM) of Propellant Tanks in Space. It describes the type of CFD models that must be developed to address the future needs of Space CFM. It also discusses the two classes of experiments currently used to validate the fidelity of the CFD models. These two experiment classes are: (a) the small-scale simulant fluid science experiments that are equipped with scientific diagnostics to elucidate the underlying two-phase fluid physics of the CFM processes; and (b) the large-scale cryogenic experiments that assess the engineering performance of the propellant tank for storage and transfer. The current status of the CFD model development and validation is briefly assessed by presenting examples of segregated two-phase flow problems that have been successfully modeled. The future model development directions for CFM situations involving more complex interpenetrating phases are also defined.

Cryogenic Fluid Management↗

Comparison of Liquefaction Testing with Liquid Nitrogen and Liquid Oxygen

Liquid nitrogen is often used as a substitute for oxygen testing due to safety concerns, and the general similarity between their fluid properties. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, an opportunity arose to compare liquid nitrogen and liquid oxygen behavior using the same test hardware in similar test conditions. Comparative testing would verify whether the system response to nitrogen and oxygen would behave in a similar manner. Tests that were investigated include system boil-off heat load determination, autogenous pressurization, cryocooler loop initiation, and cryocooler loop operations. Results from testing are shown and compared to verify that liquid nitrogen and liquid oxygen tests yield similar system responses, and that nitrogen can be used as a substitute for oxygen in developmental tests at cryogenic temperatures.

Cryogenic Fluid Management↗

Low Leakage Valves for Long Duration Missions

This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.