DOE OSTI · 1046495
Cameco UO 3 Materials Analysis
Abstract
Uranium trioxide (UO 3 ) was characterized using a variety of techniques to better understand its physical properties. Scanning electron microscope (SEM) images were collected to examine particle morphology, which consisted of semi-spherical particles that tended to agglomerate before sonication. Particle size analysis revealed a singular mode distribution with a mean particle size of 43.0 {micro}m. After sonication a bimodal distribution was produced with peak particle sizes at 0.226 μm and 9.43 μm. The O/U ratio was measured to be 3.09 by Cameco in 2009, by gravimetric analysis. X-ray diffraction (XRD) showed that the sample was mostly Υ-UO 3 (87.1%) with a small amount of UO 3 ̣ 0.80 H 2 O (12.9%). Bulk and tap densities were determined to be 3.678 ±} 0.2 and 4.81 ± 0.2 g/cm 3 }, respectively (crystalline density is 7.3 g/cm 3 ). The stoichiometry was measured to be 2.99 in 2012.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Hill, Mary Ann, Nolen, Blake Penfield, Wermer, Joseph R., Wilkerson, Marianne P., Fredenburg, David A., Wagner, Gregory L., Papin, Pallas A., Scott, Brian L., Guidry, Dennis Ray. 2012-07-12. Cameco UO 3 Materials Analysis. https://doi.org/10.2172/1046495. https://searchnasa.com/record/osti%3A1046495/cameco-uo-3-materials-analysis