Search NASA⌕ Search

DOE OSTI · 1764157

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 3d Raw Data

Abstract

XPS of Si/GaN photocathode after 1 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission spectroscopy (XPS) on a Kratos Axis Ultra DLD system at a takeoff angle of 0° relative to the surface normal. An Al Kα source (hν = 1486.6 eV) was used to excite the core level electrons. Pass energy of 20 eV was used for the narrow scan of core levels and valence band spectra, and step size of 0.05 eV and 0.025 eV, respectively. The Spectral fitting was conducted using CasaXPS analysis software. The binding energy scales of all core levels were corrected to the N 1s of Ga – N bond at 397.8 eV. X-ray photoemission spectroscopy (XPS) O1s core level spectra from 1 hour chronoamperometry (CA) tested Si/GaN sample, and deconvolution shows O - Ga bond, O - N - Ga bond, and OH - H2O bond.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zeng, Guosong, Pham, Tuan Anh, Vanka, Srinivas, Liu, Guiji, Song, Chengyu, Cooper, Jason K, Mi, Zetian, Ogitsu, Tadashi, Toma, Francesca. 2021-02-04. Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 3d Raw Data. https://doi.org/10.17025/1764157

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1a Raw Data

10 hours chronoamperometry (CA) testing under 1 sun illumination and constant bias at -0.6 V vs RHE, the corresponding Faradaic efficiency reveals a self-improving nature of GaN, inset: CA testing on bare Si for 5 hours under 1 sun illumination and -0.6 V vs RHE, this bare Si photocathode rapidly drops down to < 0.05 mA/cm2 within an hour. Both CA testing performed in 0.5 M H2SO4 (pH=0.4).

photocathode↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 1c Raw Data

Intermittent chronoamperometry (CA) testing was performed on Si/GaN photocathode in hourly manner. The LSV scan at 0 hour, 1 hour CA, 2 hours CA, 3 hours CA, 4 hours CA, 6 hours CA, 8 hours CA and 10 hours CA were recorded to track the changes of the photoelectrochemica (PEC) performance of the photocathode. The scan range was set to be 0V vs open circuit voltage (Eoc) to -0.7V vs RHE. Test was performed under one sun illumination in 0.5M H2SO4 (pH=0.4).

photocathode↗