Search NASA⌕ Search

DOE OSTI · 1835111

End-to-end orientation estimation from 2D cryo-EM1images

Abstract

Cryo-electron microscopy (cryo-EM) is a Nobel Prize-winning technique for deter-mining high-resolution 3D structures of biological macromolecules. A 3D structure is reconstructed from hundreds of thousands of noisy 2D projection images. However, existing 3D reconstruction methods are still time-consuming, and one of the major computational bottlenecks is to recover the unknown orientation of the particle in16each 2D image. The dominant methods typically exploit expensive global search on each image to estimate the missing orientations. Here, a novel end-to-end supervised learning method is introduced to directly recover the missing orientations from 2D cryo-EM images. A neural network is used to approximate the mapping from images to orientations. Furthermore, a robust loss function is proposed for optimizing the parameters of the network, which can handle both asymmetric and symmetric 3D structures. Experiments on synthetic datasets with various symmetry types confirm that the neural network is capable of recovering orientations from 2D cryo-EM images, and the results on one real cryo-EM dataset further demonstrate its potential in more challenging imaging conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lian, Ruyi, Huang, Bingyao, Wang, Liguo, Liu, Qun, Lin, Yuewei, Ling, Haibin. 2021-11-22. End-to-end orientation estimation from 2D cryo-EM1images. https://doi.org/10.1107/s2059798321011761

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

Improved Three-Dimensional Reconstructions in Electron Ptychography through Defocus Series Measurements

A detailed analysis of ptychography for three-dimensional (3D) phase reconstructions of thick specimens is performed. Here, we introduce multi-focus ptychography, which incorporates a 4D-STEM defocus series to enhance the quality of 3D reconstructions along the beam direction through a higher overdetermination ratio. This method is compared with established multi-slice ptychography techniques, such as conventional ptychography, regularized ptychography, and multi-mode ptychography. Additionally, we contrast multi-focus ptychography with an alternative method that uses virtual optical sectioning through a reconstructed scattering matrix (S-matrix), which offers more precise 3D structure information compared to conventional ptychography. Our findings from multiple 3D reconstructions based on simulated and experimental data demonstrate that multi-focus ptychography surpasses other techniques, particularly in accurately reconstructing the surfaces and interface regions of thick specimens.

3D reconstruction↗