Search NASA⌕ Search

DOE OSTI · 23082960

Class II algorithm for charged-particle transport simulation - Paper 142

Abstract

Simulation of the transport of high-energy charged particles is difficult because of the large number of interactions experienced by these particles before being brought to rest. Possible strategies to deal with this difficulty were analyzed by Berger. Most modern Monte Carlo codes use a mixture of complete-grouping (class I) and mixed (class II) schemes. In class I simulations, the global effect of all the interactions that occur along a trajectory segment of a given length s is described by means of precalculated distributions derived from multiple-scattering theories. In class II simulations, hard (or catastrophic) interactions (with energy loss W or polar scattering angle {theta} larger than given cutoff values) are sampled individually, while the effect of soft interactions (with energy losses and scattering angles smaller than the respective cutoffs) is described using a multiple-scattering approach. Although Berger effectively employed class II simulation only for energy-loss events, he did recognize the advantages of class II over class I also for multiple elastic scattering. On the one hand, because hard interactions are described exactly according to the adopted differential cross sections (DCSs), class II schemes are more accurate. On the other hand, multiple-scattering approximations, which are still required to describe the cumulative effect of soft interactions, are simpler and more accurate when individual interactions are limited to small energy transfers and angular deflections. For instance, for path lengths that are not too small, but still much less than the CSDA range, the energy-loss distribution due to multiple soft events is approximately Gaussian, by virtue of the central limit theorem. Similarly, the angular distribution caused by multiple small-angle deflections is also approximately Gaussian. However, class II schemes are more difficult to implement because of their dependence on specificities of the DCSs. In this article we briefly present the essentials of the class II algorithm for charged particles implemented in the last version of the penelope code, and provide evidence of its accuracy and stability with the simulation parameters. (authors)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Salvat, Francesc. 2014-09-15. Class II algorithm for charged-particle transport simulation - Paper 142. https://searchnasa.com/record/osti%3A23082960/class-ii-algorithm-for-charged-particle-transport-simulation-paper-142

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗