Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A secure measurement unit for an inspection system used in nuclear arms-control verification

Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current interrupt method for calculating the electrochemical impedance in a solid oxide electrolysis stack

Here, in this work the time domain response of Solid Oxide Electrolysis Cells (SOEC) to a current interruption was transformed into the frequency domain using a carrier function Laplace transform, which is fit to the experimental data using a MATLAB Complex Nonlinear Least Squares (CNLS) solver. The hardware implementation, consisting principally of a high-speed switch and a fast-logging Analog to Digital Converter (ADC), was assembled and tested using a calibration module to assess the accuracy, repeatability, and speed of acquisition of the prototype device as compared against a calibrated commercial impedance spectrometer. Additionally, the current interrupt device and commercial FRA were used to acquire the impedance spectra of a four cell SOEC stack with a large, 300 cm 2 , active cell area.

SOEC↗

The GlueX beamline and detector

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μs$. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. Here, we describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting low energy signals from raw LArTPC waveforms using deep learning techniques — A proof of concept

Here, we investigate the feasibility of using deep learning techniques, in the form of a one-dimensional convolutional neural network (1D-CNN), for the extraction of signals from the raw waveforms produced by the individual channels of liquid argon time projection chamber (LArTPC) detectors. A minimal generic LArTPC detector model is developed to generate realistic noise and signal waveforms used to train and test the 1D-CNN, and evaluate its performance on low-level signals. We demonstrate that our approach overcomes the inherent shortcomings of traditional cut-based methods by extending sensitivity to signals with ADC values below their imposed thresholds. This approach exhibits great promise in enhancing the capabilities of future generation neutrino experiments like DUNE to carry out their low-energy neutrino physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gold Nanorod-Affibody Conjugates Mediate Cancer Photothermal Therapy under 808 nm LED Irradiation

Current HER2-targeted therapies including monoclonal antibodies, antibody-drug conjugates (ADCs) and small-molecule tyrosine kinase inhibitors face limitations such as hepatotoxicity, development of treatment resistance, and subsequent disease relapse. To overcome these challenges, this study combines the specificity of a HER2-targeting affibody molecule (Z HER2:2891 -Cys) with the photothermal properties of gold nanorods (AuNRs), forming bioconjugates (Affi–AuNRs) for selective treatment of HER2-positive cancer cells. Affi–AuNRs were fabricated via a two-step surface modification: (i) ligand exchange to displace cetyltrimethylammonium bromide (CTAB) with poly(ethylene glycol) methyl ether thiol (mPEG-SH), and (ii) covalent attachment of the affibody molecule via Au–S chemistry. Affi-AuNRs exhibited a photothermal conversion efficiency of 64 ± 5%, comparable to that of CTAB-stabilized AuNRs (59 ± 4%). Confocal microscopy confirmed that Affi-AuNRs are selectively internalized by HER2-positive SKOV-3 cells, with minimal uptake by HEK293T cells, which have low HER2 expression. Upon exposure to 808 nm near-infrared (NIR) LED irradiation (408 mW cm –2 , 15 min), Affi-AuNRs significantly reduced SKOV-3 cell viability by 85 ± 9% (p < 0.001) relative to untreated controls with no detectable cytotoxicity in HEK293T cells. These results demonstrate HER2-selective photothermal cytotoxicity mediated by Affi–AuNRs under defined 808 nm LED irradiation conditions, supporting their continued development as nanotheranostic tools that integrate affibody-mediated specificity with plasmonic heating.

36 MATERIALS SCIENCE↗

Excited state dynamics of azanaphthalenes reveal opportunities for the rational design of photoactive molecules

Abstract Various photoactive molecules contain motifs built on aza-aromatic heterocycles, although a detailed understanding of the excited state photophysics and photochemistry in such systems is not fully developed. To help address this issue, the non-adiabatic dynamics operating in azanaphthalenes under hexane solvation was studied following 267 nm excitation using ultrafast transient absorption spectroscopy. Specifically, the species quinoline, isoquinoline, quinazoline, quinoxaline, 1,6-naphthyridine, and 1,8-naphthyridine were investigated, providing a systematic variation in the relative positioning of nitrogen heteroatom centres within a bicyclic aromatic structure. Our results indicate considerable differences in excited state lifetimes, and in the propensity for intersystem crossingvsinternal conversion across the molecular series. The overall pattern of behaviour can be explained in terms of potential energy barriers and spin-orbit coupling effects, as demonstrated by extensive quantum chemistry calculations undertaken at the SCS-ADC(2) level of theory. The fact that quantum chemistry calculations can achieve such detailed and nuanced agreement with experimental data across a full set of six molecules exhibiting subtle variations in their composition provides an excellent example of the current state-of-the-art and is indicative of future opportunities for rational design of photoactive molecules.

Chemistry↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

ATLAS HL-LHC Demonstrators with Data Carousel: Dataon-Demand and Tape Smart Writing

The High Luminosity upgrade to the LHC (HL-LHC) is expected to deliver scientific data at the multi-exabyte scale. To tackle this unprecedented data storage challenge, the ATLAS experiment initiated the Data Carousel project in 2018. Data Carousel is a tape-driven workflow in which bulk production campaigns with input data resident on tape are executed by staging and promptly processing a sliding window to disk buffer such that only a small fraction of inputs are pinned on disk at any one time. Put in ATLAS production before Run3, Data Carousel continues to be our focus for seeking new opportunities in disk space savings, and enhancing tape usage throughout the ATLAS Distributed Computing (ADC) environment. These efforts are highlighted by two recent ATLAS HL-LHC demonstrator projects: data-on-demand and tape smart writing. In this paper, we will discuss the recent studies and outcomes from these projects. The research was conducted together with site experts at CERN and Tier-1 centers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the upgraded PreProcessor of the ATLAS Level-1 Calorimeter Trigger

The PreProcessor of the ATLAS Level-1 Calorimeter Trigger prepares the analogue trigger signals sent from the ATLAS calorimeters by digitising, synchronising, and calibrating them to reconstruct transverse energy deposits, which are then used in further processing to identify event features. During the first long shutdown of the LHC from 2013 to 2014, the central components of the PreProcessor, the Multichip Modules, were replaced by upgraded versions that feature modern ADC and FPGA technology to ensure optimal performance in the high pile-up environment of LHC Run 2. This paper describes the features of the new Multichip Modules along with the improvements to the signal processing achieved.

47 OTHER INSTRUMENTATION↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

In this study, ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC) 2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

47 OTHER INSTRUMENTATION↗

Performance evaluation of an RFSoC operating in a 1.25 Tesla magnetic field

Here, the Belle II experiment at the SuperKEKB collider is preparing for an upgrade after 2027–2028 to handle higher luminosity and increased background rates. A Radio Frequency System-on-Chip (RFSoC) has been identified as a potential candidate for a common front-end upgrade for subsystems requiring high-speed waveform digitization. The RFSoC's ADC and DAC channels were tested across various magnetic field strengths and a few different field orientations. Power consumption and boot memory functionality were also assessed. Results indicate stable operation with negligible performance degradation, suggesting the RFSoC's viability for high-speed digitization tasks in high magnetic field environments.

47 OTHER INSTRUMENTATION↗