Search NASASearch

SEARCH · Search NASA

Results for “Free energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

785 records · Page 10

Breaking the Energy Barrier of Heavy Metal Ion Diffusion in Micropores with Mesoporous 3D Graphene for Fast and Efficient Cu2+ Removal

Efficient removal of heavy metals from water critically depends not only on adsorption capacity but also on ion diffusion kinetics and the associated energy barriers. In conventional carbon adsorbents, severe diffusion confinement within micropores restricts ion transport, resulting in sluggish adsorption kinetics and large apparent activation energies despite high specific surface areas. Here, we demonstrate that this fundamental limitation is overcome by engineering meso/macroporous architectures in the 3D graphene materials synthesized via our discovered alkali-metal reactions with\\\\r\\\\n2\\\\r\\\\nCO. The unique 3D graphene materials possess defect-rich graphene frameworks with interconnected meso/macroporous networks, exhibiting simultaneously high surface area and greatly enhanced meso/macropore volume that enable efficient access to adsorption sites. As a result, the Cu2+ adsorption on 3D graphene proceeds with very low activation energies (4.98 kJ mol–1), which is almost 4 times smaller than on activated carbon (23.1 kJ mol–1). This finding offers a promising platform for efficient and sustainable water purification.

25 ENERGY STORAGE

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying [Pacific Northwest National Laborato

Leveraging Solar Thermal Energy for Net-Zero Brewing

Firestone Walker Brewing Company (FWBC), Paso Robles, California, owns a 1-million-barrel (BBL) brewery that requires up to 5 MW of process heat in form of saturated steam. Firestone Walker Brewery has set a goal of reducing carbon emissions by 50% for our 1 million BBL brewery.

Palacio, Juan [Firestone Walker Inc., Paso Robles,

Detecting the full photoemission cone from laser-based ARPES experiments by leveraging deflector technology

Angle-resolved photoemission spectroscopy (ARPES) provides a direct access to the electronic band structure of solid and molecular systems. The momentum range accessible by this technique depends directly on the photon energy used, and low-photon-energy sources are insufficient to photoemit electrons over the full Brillouin zone of most quantum materials. In addition, while electrons are emitted over a 2π solid angle, conventional hemispherical analyzers only collect a small subset of those electrons. A previous work [Gauthier et al., Rev. Sci. Instrum. 92, 123907 (2021)] demonstrated that electrons emitted over a larger field-of-view can be acquired in one fixed configuration by accelerating them toward the analyzer with a bias voltage. Here, in this study, we extend this work by leveraging the deflector technology of novel ARPES hemispherical analyzers. We demonstrate the ability to detect all 2π photoemitted electrons in a fixed configuration for various materials, such as gold, cuprates, and transition-metal dichalcogenides. This approach is especially advantageous for time-resolved ARPES, as electron dynamics over a large momentum range can be accessed with identical measurement conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Particle production by time-varying dark energy and the end of cosmic expansion

We consider various possible consequences of time-varying dark energy due to a quintessence scalar field whose energy density is partially converted to particles as the field evolves down its potential. This particle production acts as a source of thermal friction on the field that can make it difficult to distinguish whether dark energy is due to a radiating field rolling down a steep potential, a purely self-interacting field moving down a flatter potential, or a cosmological constant. By reducing the acceleration of the scalar field, thermal friction increases the amount of accelerated expansion and can cause a sizable bump in the quintessence equation of state. We take special interest in the case where a steep potential rapidly changes from positive to negative as the field evolves, resulting in the end of cosmic expansion and the beginning of contraction. Even in this case, we find that thermal friction lengthens the period of accelerated expansion and consequently delays the end of cosmic expansion, making it challenging to detect the impending transition to contraction using conventional cosmological tests. However, particle production can also provide alternative avenues for detection by generating a background of thermal dark radiation, partly comprised of neutrinos or other particles, whose energy density exceeds the remnant photon energy density.

cosmological neutrinos

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

The Hawaii Meteorology, Energy and Transmission (MET) Toolkit

Reliable long-term resource adequacy and grid planning in Hawaii require precise, multi-decadal meteorological records. This paper introduces the Hawaii Meteorology, Energy and Transmission (MET) Toolkit, a 26-year (2000-2025) high-fidelity atmospheric dataset developed by the National Laboratory of the Rockies (NLR). We present a validation study of the underlying WRF model configurations, comparing the legacy MYNN PBL scheme against an alternative YSU formulation. Using vertical lidar profiles and surface buoy data, our analysis identified a foundational geometric distortion in the legacy NOW-23 Hawaii dataset caused by an incorrect grid projection. When evaluated on a corrected, zero-distortion grid, the YSU scheme demonstrated superior performance in bias and cRMSE compared to the legacy setup. To address these findings, the MET Toolkit has been re-produced as a unified 26-year record using the optimized YSU setup and corrected geometry. This dataset offers the Hawaii power sector a robust, validated, and homogenous reference for future grid resilience and energy integration.

24 POWER TRANSMISSION AND DISTRIBUTION

Computational simulation of asymmetric phase transformation in cracked Li₇La₃Zr₂O₁₂: Variant selection and chemo-mechanical implications

Coupling between microcracks and phase transformation in ion-conducting ceramics can jointly affect mechanical responses and ion transport. In this work we investigate the cubic-to-tetragonal phase transformation in Li₇La₃Zr₂O₁₂ in the presence of a microcrack under hydrostatic loading and quantify its implications for crack-tip stress concentration and Li-ion transport using phase-field and molecular dynamics simulations. The phase transformation exhibits a strong asymmetry between hydrostatic tension and compression. Under tension, the crack edge nucleates one tetragonal variant that amplifies the crack-tip stress intensity and promotes crack opening. Under compression, the crack tip nucleates a different tetragonal variant that enhances the stress-induced crack-closure tendency. Effective Li diffusivity analysis shows faster transport degradation under compression due to accelerated transformation kinetics, exposing a trade-off between mechanical stability and ionic conductivity. These results highlight the intertwined nature of cracking, phase transformation, and ionic transport in ion-conducting oxides and provide mechanistic insights into chemo-mechanical degradation of solid electrolytes.

36 MATERIALS SCIENCE

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie

Time-dependent scenario modeling for the ST-E1 fusion power plant

ST-E1 is a low aspect ratio fusion power plant being designed by Tokamak Energy targeting 1.5 GW of fusion power. Characterization of the ST-E1 flat-top scenario is described elsewhere McNamara et al (2026 Nucl. Fusion 66 086008); here we focus on addressing the question of how to ramp-up the ST-E1 plasma from an initial state following breakdown and flux-surface formation to the target flat-top state. Being low-aspect ratio, the available solenoid flux of ST-E1 is limited. Therefore, particular consideration is placed on developing ramp-up scenarios that predominantly use inductive flux provided by external vertical field coils. Through time-dependent modeling with METIS, we show that this is possible when the ramp-up is performed at relatively high plasma density: although auxiliary current drive efficiency is reduced, this is significantly outweighed by (1) higher electron-ion collisional equilibration, (2) higher fusion power once ions become sufficiently hot, (3) higher poloidal beta for increased vertical-field flux, and (4) potentially favorable exhaust compatibilities. Ultimately, we show the target ST-E1 flat-top performance can be reached after a ramp-up period lasting 150 s using less than 40 Vs of solenoid flux (with vertical field providing ∼ 90 Vs of flux). The sensitivity to model assumptions are presented, with the general observation that deleterious effects can be mitigated through minor alterations of the auxiliary power temporal waveform and/or total auxiliary power level. The impact of a solenoid and the auxiliary power mix (electron cyclotron heating only versus electron and ion cyclotron heating) on the ST-E1 ramp-up success are also discussed in appendices. On this latter topic, we show that the effect of direct-ion heating during ramp-up is obscured by the uncertainty in the pedestal dynamics, identifying a clear line of future work required to make a definite decision on the ST-E1 auxiliary power mix.

current ramp-up

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION

Light–Material Interactions Using Laser and Flash Sources for Energy Conversion and Storage Applications

Abstract This review provides a comprehensive overview of the progress in light–material interactions (LMIs), focusing on lasers and flash lights for energy conversion and storage applications. We discuss intricate LMI parameters such as light sources, interaction time, and fluence to elucidate their importance in material processing. In addition, this study covers various light-induced photothermal and photochemical processes ranging from melting, crystallization, and ablation to doping and synthesis, which are essential for developing energy materials and devices. Finally, we present extensive energy conversion and storage applications demonstrated by LMI technologies, including energy harvesters, sensors, capacitors, and batteries. Despite the several challenges associated with LMIs, such as complex mechanisms, and high-degrees of freedom, we believe that substantial contributions and potential for the commercialization of future energy systems can be achieved by advancing optical technologies through comprehensive academic research and multidisciplinary collaborations.

Materials Science

The Maximal Entanglement Limit in Statistical and High-energy Physics

These lectures advocate the idea that quantum entanglement provides a unifying foundation for both statistical physics and high-energy interactions. I argue that, at sufficiently long times or high energies, most quantum systems approach a Maximal Entanglement Limit (MEL) in which phases of quantum states become unobservable, reduced density matrices acquire a thermal form, and probabilistic descriptions emerge without invoking ergodicity or classical randomness. Within this framework, the emergence of probabilistic parton model, thermalization in the break-up of confining strings and in high-energy collisions, and the universal small-x behavior of structure functions arise as direct consequences of entanglement and geometry of high-dimensional Hilbert space.

36 MATERIALS SCIENCE

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE

A review of United States energy-only generator interconnection service policy and considerations for reform

Grid interconnection has emerged as a significant obstacle to the development of new electricity resources. There is growing interest in energy-only interconnection, which is an interconnection service option meant to allow the interconnection of new generators without ensuring their energy deliverability during all hours through the transmission system to customers. This approach potentially avoids upfront congestion-related transmission upgrades but could increase curtailment risk. Interest in energy-only interconnection is shaped by incomplete understanding of how interconnection policy functions in different jurisdictions, a knowledge gap that makes it difficult to determine how energy-only interconnection might be better used or re-designed. In this paper, we provide a regulatory review of energy-only interconnection in U.S. interconnection policy and practice, identifying jurisdictions in which rules are close to -or farther from-the theoretical concept of energy-only interconnection service. We find substantial jurisdictional differences in how energy-only interconnection is implemented, driven by differences in resource adequacy frameworks, real-time transmission operations, and state-level procurement practices. U.S. regulators have preferred local jurisdictional flexibility over federal prescription of interconnection study methods and procedures, which also contributes to differences among regions. Such findings raise fundamental questions about whether competition policies in electricity markets should extend beyond spot energy markets and into more prescriptive guidelines around interconnection rules and market entry. This paper sheds light on tensions that energy-only interconnection raises in allowing generators to access the transmission system on an as available basis and discusses how controlling thresholds for congestion-related network upgrades may be a barrier to electricity market entry.

Gorman, Will