Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Life tests of small turbine-type flowmeters in liquid hydrogen

A total of 14 turbine-type flowmeters of 2.5- and 4-cm nominal size were operated for 100 or more hours at an average fluid speed in the unobstructed, upstream pipe of 20 m/s for the smaller meters and 9 m/s for the larger meters. Calibration shifts over a 6.1 range of calibration flow rates varied from 0.5 percent to 1 percent after 50 hr of operation. It is concluded that use of ball bearings with glass-filled Teflon retainers is most likely to produce minimal calibration shift with protracted use. Bearing replacement after 50 to 100 hr is recommended, depending on accuracy requirements, for meters used at the fluid speeds of the tests.

Hobart, H. F.↗

Fabrication and life testing of thermionic converters

An unfueled converter containing a chloride-fluoride duplex tungsten emitter of 4.78 eV vacuum work function was tested for 46,647 hours at an emitter temperature of 1973 K and an electrode power output of about 8 watts/sq cm. The test demonstrated the superior and stable performance of the (110) oriented tungsten emitter at high temperatures. Three 90 UC-10 ZrC(C/U = 1.04, tungsten additive = 4 wt %) fueled converters were fabricated and tested at an emitter temperature of 1873 K. Converter containing chloride-arc-cast duplex tungsten cladding showed temperature thermionic performance and slower rate of performance drop than converter containing chloride-fluoride duplex tungsten cladding. This is believed to be due to the superior fuel component diffusion resistance of the arc-cast tungsten substrate used in the fuel cladding. It was shown that a converter containing a carbide fueled chloride-arc-cast duplex tungsten emitter with an initial electrode power output of 6.80 watts/sq cm could still deliver an electrode power output of 6.16 watts/sq cm after 18,632 hours of operation at an emitter temperature of 1873 K.

Yang, L.↗

Long-duration life tests of slip ring capsule assemblies for inertial guidance platforms

Eight slip ring capsules, each having 80 or 100 circuits, were operated for time periods ranging from 14,300 hours to 24,700 hours. The test mode simulated the motion of gimbal axes of the Saturn inertial guidance the platform in an organic free nitrogen environment. Computer-compiled noise data (approximately 45,000 recordings) were graphed as a function of test time and position within the capsules and as extreme probability distributions. Greater than ninety-nine percent of the noise measurements for the capsules with sufficient lubrication were less than 10 milliohms. Capsules with glass dielectrics did not perform significantly differently than those with filled epoxy dielectrics. The initial wear mode of prow formation was followed by rider wear. After 10 to the 8th power wipes, ring wear depth did not exceed the surface finish and the radial rider wear depth was less than 13 microns.

Cole, S. R.↗

Long life testing of spare Mariner Venus '67 hardware

The faultless performance of the Mariner Venus '67 Power Conditioning Electronics (PCE) throughout six years of continuous operation in a simulated space environment is reported. Weekly functional tests supplemented by daily monitoring verified that the PCE equipment can perform to its intended functions for at least six years without apparent performance degradation. Performance throughout the test period was very stable, there are no circuit or redundancy improvements to be considered. When the equipment was examined after the test was completed, there was no evidence of any physical damage nor any difficulty in disconnecting the wiring connectors.

Silverman, S. W.↗

Microchannel plate life tests

The behavior of the gain of a microchannel plate (MCP) during operation of the latter at moderate output currents was investigated. The total charge per unit area, Q, extracted from the MCP is shown to be the relevant quantity for evaluating MCP performance. The shape of the gain versus Q curve provides information on the gain decay process. Long periods of stable gain, frequently exhibited by channeltrons, were not observed in the present experiment.

Sandel, B. R.↗

Life test results for an ensemble of CO2 lasers

The effects of cathode material, cathode operating temperature, anode configuration, window materials, and hydrogen additives on laser lifetime are determined. Internally oxidized copper and silber-copper alloy cathodes were tested. The cathode operating temperature was raised in some tubes through the use of thermal insulation. Lasers incorporating thermally insulated silver copper oxide cathodes clearly yielded the longest lifetimes-typically in excess of 22,000 hours. The use of platinum sheet versus platinum pin anodes had no observable effect on laser lifetime. Similarly, the choice of germanium, cadmium telluride, or zinc selenide as the optical window material appears to have no impact on lifetime.

Peruso, C. J.↗

Cycle life test

Statistical information concerning cell performance characteristics and limitations of secondary spacecraft cells is presented. Weaknesses in cell design as well as battery weaknesses encountered in various satellite programs are reported. Emphasis is placed on improving the reliability of space batteries.

Harkness, J. D.↗

Life testing of Mallory cells

Tests were performed to assess the effects of storage time, storage temperature, vibration, discharge rate and temperature, and capacity of high-rate, D size, lithium sulfur dioxide cells. Data from these tests are discussed.

Dugan, D.↗

Accelerated life testing effects on CMOS microcircuit characteristics

Modifications and additions to the present process of making CMOS microcircuits which are designed to provide protective layers on the chip to guard against moisture and contaminants were investigated. High and low temperature Si3N4 protective layers were tested on the CMOS microcircuits and no conclusive improvements in device reliability characteristics were evidenced.

Source record↗

Life test of a nickel cadmium battery with a protection/reconditioning circuit

Results are discussed for a Ni-Cd battery test over a period of 8 years, 2 months and 44,213 simulated low Earth orbits. The battery cells were protected against overdischarge and reversal at discharge rates up to 25 amperes (1.25C) by a battery protection and reconditioning circuit. The circuit performed flawlessly during the test, and proved its value, both as a battery reconditioner and a cell protection device. Battery cell failures are also discussed. The test demonstrated the viability of using Ni-Cd batteries at depth-of-discharge up to 25 percent for over 5 years in a low Earth orbit.

Lanier, J. R., Jr.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

RCA SATCOM Battery in Orbit Performance Update and Accelerated Life Test Results

No significant degradation of nickel cadmium battery performance in SATCOM F1 and F2 after almost 8 and 7-3/4 years in orbit was shown. Battery minimum discharge voltage data are presented for these spacecraft. In addition, 2 groups of nickel cadmium cells which are representative of those in orbit are undergoing real time eclipse-reduced suntime cycling in the laboratory. These groups of cells, which are being cycled at a maximum of 53% and 62% depth of discharge (based on actual capacity), have completed 14 and 15 eclipse seasons, respectively. Data for these groups of cells are presented and are compared with the in-orbit battery data.

Gaston, S. J.↗

Life test results of hydride compressors for cryogenic refrigerators

A development status assessment is made, from the viewpoint of system durability, for the hydride compressors used in such cryogenic refrigerators as that of the JPL, which has operated at 29 K for 500 hours and at lower temperatures for over 1000. Attention is given to a novel hydride compressor unit which has operated through 35,000 cycles and exhibits negligible degradation of check valves, hydride particle size, and expansion valves. The power requirement for liquid hydrogen cooling can be halved through the use of recuperative hot water heating methods, making this system comparable in power use to liquid hydrogen refrigeration systems operating on electricity. Due to the lack of moving parts in hydride refrigerator designs, potential service lifetimes of many years, and perhaps decades, are being projected.

Jones, J. A.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure. Previously announced in STAR as N83-25038

Smithrick, J. J.↗

LEO life testing with different charge control

The effect of charge control on the performance of Nickel-Cadmium batteries is very important. The results of three tests performed in the Battery Test Centre of ESTEC are described. Two techniques were employed: (1) the tapering method well known for space applications, and (2) the temperature derivative technique (TDT) developed by ESTEC. In addition, a comparative study has been made between the behavior of a group of 3 batteries charged and discharged in parallel compared to an identical group discharged in parallel, but charged individually. An approach of evolution laws for the main electrical characteristics of cells is presented.

Baron, F.↗

Nickel-cadmium cell life test

Over 6,9000 Low Earth Orbit cycles were accumulated at 30% Depth of Discharge on twelve INTELSAT-design nickel-hydrogen cells. Physical equipment and cells are described. Performance characteristics are seen to be uniform. Further testing is planned to seek a failure mode, and also to investigate the effects of a new additive for nickel-hydrogen cells. Initial results indicate improved performance at higher temperatures and diminished swelling of positive nickel plates.

Wheeler, J. R.↗