Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Examining astrophysical gas cloud collapse using an optical depth-scaled, x-ray-irradiated, carbon-foam sphere

When stellar radiation interacts with a molecular cloud, the cloud's fate depends on the strength of the incident radiation and the radiation's mean-free-path within the cloud [F. Bertoldi, Astrophys. J. 346, 735–755 (1989)]. Under the right conditions, the radiation compresses the cloud and a star formation may occur. Where and when the stellar formation occurs in the cloud's collapse are open questions. Direct observation of the complete star–cloud lifecycle is nearly impossible due to the immense timescales and distances over which the interaction occurs. Laboratory astrophysics offers a way to investigate such a system by scaling the important astrophysical parameters to the laboratory. This work describes laboratory experiments to study the radiation-driven implosion of clouds, using x rays from a laser-irradiated, thin, gold foil as a surrogate star and a carbon-foam sphere as a surrogate cloud. An optically thick system, theoretically corresponding to a star-forming regime, was selected by choice of the foam density. Gold foil and sphere motions were imaged by x-ray radiography. Radiographic images show the formation of an interface between rarefied gold and carbon plasmas, a shock moving into the sphere, and a blunting of the initial sphere's shape. Measurements show that the shock moved linearly around 64 μm/ns into the sphere, and the gold–carbon interface formed by 2 ns at the sphere edge remained stationary. The deformation of the sphere was driven by the incident radiation and not by mechanical pressures applied by gold plasma. The blunting of the sphere was likely due to the geometric reduction of flux near the sphere's poles. Higher x-ray flux near the sphere's equator caused high compression and a faster shock, which flattened the sphere. We will discuss the results and implications of our observations.

VanDervort, R. W. [University of Michigan 1 , Ann ↗

Structure of Self-Generated Magnetic Fields in Laser-Solid Interaction from Proton Tomography

Self-generated magnetic fields in laser-solid interactions are experimentally characterized to reveal the 3D location and local field strength, rather than path-integrated quantities, using multi-view proton radiography and tomographic inversion. We infer magnetic fields that extend several millimeters off the target into the hot, rarefied corona, sufficient to strongly magnetize the plasma (Ω e τ e ≫ 1). The data are compared to MHD simulations incorporating recent improvements in modeling magnetic field generation and transport; the volume-averaged coronal field strength and magnetic flux agree to within 25% using a model with magnetic re-localization of transport, although the near-target morphology is not reproduced. This work demonstrates tomographic proton radiography as a valuable tool for investigating magnetic fields in laser-produced plasmas.

High-energy-density plasmas↗

Multi-Probe FY25 Omega EP Shot Request [Slides]

The goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe types (x ray, proton, neutron, and electron) in future LANL radiographic facilities. X-ray and proton platforms have been demonstrated. The first attempts at simultaneous radiography were hampered by cross talk, which was the subject of FY23 & FY24 experiments. The major goal for FY25 is to demonstrate simultaneous radiography of both static and dynamic objects.

36 MATERIALS SCIENCE↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Locating tube blockage that X-ray cannot detect

Alternate choices to X-ray use in detecting foreign materials in metal assemblies are available, including negative radiography, neutron radiography, liquid-crystal inspection and ultrasonics. Advantages and disadvantages of each method are given. Report is valuable in testings and inspections, including heat exchangers and piping systems.

Hendron, J. A.↗

A comparison of screening techniques for ceramic capacitors

The techniques involved are ultrasonic scanning, neutron radiography, scanning laser acoustic microscopy, and voltage conditioning. The test capacitor, for this first phase, is a 0.47 uF, 50V capacitor style CKR06. Eighteen of 768 devices failed in voltage conditioning with elapsed times from 15 minutes to 1239 hours. Eleven of the failures were detected by ultrasonic scanning. Four failures were found by neutron radiography. Fourteen failures showed up in the acoustic microscopy test. Three failures in voltage conditioning were not detected by any of the techniques. Failures were confirmed by destructive physical analysis. There is no direct relationship between the size of the defect and electrical failure.

Kiernan, G. F.↗

NDE of structural ceramics

Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

Klima, S. J.↗

NDE of structural ceramics

Radiographic, ultrasonic, scanning laser acoustic microscopy (SLAM), and thermo-acoustic microscopy techniques were used to characterize silicon nitride and silicon carbide modulus-of-rupture test specimens in various stages of fabrication. Conventional and microfocus X-ray techniques were found capable of detecting minute high density inclusions in as-received powders, green compacts, and fully densified specimens. Significant density gradients in sintered bars were observed by radiography, ultrasonic velocity, and SLAM. Ultrasonic attenuation was found sensitive to microstructural variations due to grain and void morphology and distribution. SLAM was also capable of detecting voids, inclusions and cracks in finished test bars. Consideration is given to the potential for applying thermo-acoustic microscopy techniques to green and densified ceramics. The detection probability statistics and some limitations of radiography and SLAM also are discussed.

Klima, S. J.↗

NDE reliability and process control for structural ceramics

The reliability of microfocus x-radiography and scanning laser acoustic microscopy for detecting microvoids in silicon nitride and silicon carbide was statistically evaluated. Materials- and process-related parameters that influenced the statistical findings in research samples are discussed. The use of conventional x-radiography in controlling and optimizing the processing and sintering of an Si3N4-Si02-Y203 composition designated NASA 6Y is described. Radiographic evaluation and guidance helped develop uniform high-density Si3N4 modulus-of-rupture bars with improved four-point flexural strength (857, 544, and 462 MPa at room temperature, 1200 C, and 1370 C, respectively) and reduced strength scatter.

Baaklini, G. Y.↗

Nondestructive evaluation of structural ceramics

A review is presented on research and development of techniques for nondestructive evaluation and characterization of advanced ceramics for heat engine applications. Highlighted in this review are Lewis Research Center efforts in microfocus radiography, scanning laser acoustic microscopy (SLAM), scanning acoustic microscopy (SAM), scanning electron acoustic microscopy (SEAM), and photoacoustic microscopy (PAM). The techniques were evaluated by applying them to research samples of green and sintered silicon nitride and silicon carbide in the form of modulus-of-rupture bars containing seeded voids. Probabilities of detection of voids were determined for diameters as small as 20 microns for microfucus radiography, SLAM, and SAM. Strengths and limitations of the techniques for ceramic applications are identified. Application of ultrasonics for characterizing ceramic microstructures is also discussed.

Klima, Stanley J.↗

NDE reliability and process control for structural ceramics

The reliability of microfocus X-radiography and scanning laser acoustic microscopy for detecting microvoids in silicon nitride and silicon carbide was statistically evaluated. Materials- and process-related parameters that influenced the statistical findings in research samples are discussed. The use of conventional X-radiography in controlling and optimizing the processing and sintering of an Si3N4-SiO2-Y2O3 composition designated NASA 6Y is described. Radiographic evaluation and guidance helped develop uniform high-density Si3N4 modulus-of-rupture bars with improved four-point flexural strength (857, 544, and 462 MPa at room temperature, 1200 C, and 1370 C, respectively) and reduced strength scatter.

Baaklini, G. Y.↗

Locating Residual Wax In Coolant Channels

Neutron inspection finds deposits and defects invisible to x rays. Neutron radiography detects many low-density materials even when surrounded by larger quantities of denser materials. Materials with similar properties and densities often appear quite different when viewed by neutron radiography. Technique gives comprehensive view of hidden channels.

Guthrie, Douglas M.↗

Optimization of Processing of Si3N4

Process changes iterated under guidance of x-radiography. In recent work at NASA Lewis Research Center, density gradients in sintered silicon nitride, characterized by x-radiography, identified and appeared strongly dependent upon powder-processing and sintering conditions. NASA technical memorandum describes systematic investigation, based upon preliminary work, of density-gradient/flexural-strength relationships as affected by processing.

Sanders, William A.↗

Flaw imaging and ultrasonic techniques for characterizing sintered silicon carbide

The capabilities were investigated of projection microfocus x-radiography, ultrasonic velocity and attenuation, and reflection scanning acoustic microscopy for characterizing silicon carbide specimens. Silicon carbide batches covered a range of densities and different microstructural characteristics. Room temperature, four point flexural strength tests were conducted. Fractography was used to identify types, sizes, and locations of fracture origins. Fracture toughness values were calculated from fracture strength and flaw characterization data. Detection capabilities of radiography and acoustic microscopy for fracture-causing flaws were evaluated. Applicability of ultrasonics for verifying material strength and toughness was examined.

Baaklini, George Y.↗

Radiographic and ultrasonic characterization of sintered silicon carbide

The capabilities were investigated of projection microfocus X-radiography, ultrasonic velocity and attenuation, and reflection scanning acoustic microscopy for characterizing silicon carbide specimens. Silicon carbide batches covered a range of densities and different microstructural characteristics. Room temperature, four point flexural strength tests were conducted. Fractography was used to identify types, sizes, and locations of fracture origins. Fracture toughness values were calculated from fracture strength and flaw characterization data. Detection capabilities of radiography and acoustic microscopy for fracture-causing flaws were evaluated. Applicability of ultrasonics for verifying material strength and toughness was examined.

Baaklini, G. Y.↗

Radiographic instrumentation for DPM experiments

New developments in x-ray radiography that may be applicable to containerless experimentation are presented. The two features discussed are the use of radiography to determine the position and shape of the solid-liquid interface and, with the aid of appropriate markers, the flow patterns in either the surface or bulk of the liquid state. Both surface energy and fluid viscosity measurements can be made with the aid of the described radiographic system.

Fripp, Archie L.↗

The Development of Engineering Tomography for Monolithic and Composite Materials and Components

The research accomplishments under this grant were very extensive in the areas of the development of engineering tomography for monolithic and composite materials and components. Computed tomography was used on graphite composite pins and bushings to find porosity, cracks, and delaminations. It supported the following two programs: Reusable Launch Vehicle (RLV) and Southern Research institute (SRI). Did research using CT and radiography on Nickel based Superalloy dogbones and found density variations and gas shrinkage porosity. Did extensive radiography and CT of PMC composite flywheels and found delamination and non-uniform fiber distribution. This grant supported the Attitude Control Energy Storage Experiment (ACESE) program. Found broken fibers and cracks of outer stainless steel fibers using both radiographic and CT techniques on Pratt and Whitney fuel lines; Supported the Pratt & Whitney and Aging Aircraft engines program. Grant research helped identify and corroborate thickness variations and density differences in a silicon nitride "ROTH" tube using computed tomography.

Hemann, John↗