Quantization of the Higher Berry Curvature and the Higher Thouless Pump

Here, we show that for families of 1d lattice systems in an invertible phase, the cohomology class of the higher Berry curvature can be refined to an integral degree-3 class on the parameter space. Similarly, for families of U(1)-invariant 2d lattice systems in an invertible phase, the higher Thouless pump can be refined to an integral degree-2 class on the parameter space. We show that the 2d Thouless pump can be identified with an excess Berry curvature of a flux insertion.

97 MATHEMATICS AND COMPUTING↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Power HIL Evaluation of Inverter Controls for 100% Inverter-Based Bulk Power Systems

NREL's Power Electronic Grid Interface (PEGI) Workshop, held October 13, 2020, focused on the research challenges of operating power systems with ever-higher levels of inverter-based generation and power-electronic-based load. This presentation discusses a power hardware-in-the-loop evaluation of inverter controls for 100% inverter-based bulk power systems.

grid integration↗

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY↗

Impedance Methods for Analyzing Stability Impacts of Inverter-Based Resources: Stability Analysis Tools for Modern Power Systems

Power systems around the world are undergoing a major transformation because of the increasing shares of renewable energy, growing deployment of energy storage systems, proliferation of distributed energy resources, electrification of other sectors, and so on. In the United States, wind and solar provided almost 10% of electricity in 2019. The U.S. Energy Information Administration, in its 2020 Annual Energy Outlook, forecasted that the share of electricity from renewables will reach 38% by 2050, of which more than 80% will come from wind and solar. Wind and solar, along with battery energy storage systems, interface with the grid using power electronic inverters; hence, they are collectively referred to as inverter-based resources (IBRs). The increasing annual share of electricity from IBRs in a power system means that during more times of the year, the system will operate at a much higher concentration of IBRs. Figure 1 presents the hourly share of wind and solar generation in the Electric Reliability Council of Texas (ERCOT) system in Texas in 2019. While the annual wind share was at 20%, the instantaneous percentage share was much higher. Moments of high shares of IBRs (>50%) will continue to grow as more IBRs will be deployed in a power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Power Oak Ridge Converter (ORC) for Extreme Fast Charging Applications

This project report presents a novel power converter system called Oak Ridge Converter (ORC), a patented technology developed by the Oak Ridge National Laboratory (ORNL) for XFC wireless EV charging systems. ORC integrates the grid interface converter (also known as the active front-end rectifier with power factor correction) with the high-frequency inverter stage, promoting size and cost-effective charging technology with reduced infrastructure costs. The integration of the front-end rectifier with the high-frequency inverter truly eliminates one power conversion stage and achieves more than 33% size, weight, volume, and cost reduction on the wireless charging systems. Furthermore, ORC eliminates the primary side direct current (DC) bus bulk capacitors that are usually aluminum electrolytic capacitors and replaces them with very small, cost-effective, highly reliable, and high-temperature operation-capable alternate current (AC) film capacitors. ORC is also applicable to both single-phase and poly-phase couplers. When used with polyphase couplers, ORC further improves the power density of the overall system with higher power density power electronics. Moreover, ORC is inherently bidirectional and allows the system to provide power back to the grid for grid ancillary or grid support services. The ORC, based on a patented ORNL technology, is an excellent approach to resolving the high-power charging problems as described above, which directly converts the 60 hertz (Hz) line frequency into high frequency (i.e., 85 kilohertz (kHz)) to use with a high-frequency isolation transformer or wireless charging coils while eliminating the primary side number of power conversion stages from two to one. The result of the project is a prototype and reference design for a high-power wireless charging system—including power electronics, magnetics, and thermal—serving as a baseline for product development. The proposed system results are demonstrated for 270 kW of output power, with the system's overall efficiency of 92% from the AC grid, achieving less than 3% current total harmonic distortion (THD) and around 0.99 power factor (PF).

33 ADVANCED PROPULSION SYSTEMS↗

UNIFI 1-MW Multi-Vendor Grid-Forming Inverter Test Updates

This presentation gives an update on UNIFI 1MW multi-vendor GFM inverter testing. The 1MW demo enters the last stage of the test, which is the integration test. And the main objectives of the integration tests include: 1) explore the interoperability of dispatching a future grid with energy mix (GFM inverters, GFL inverters and synchronous machine). The presentation highlights one example test, ROCOF, and summarizes all the key learning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reconstruction of 2D line-integrated electron density using angular filter refractometry and a fast marching Eikonal solver

Refraction of an optical probe beam by a plasma can be measured with angular filter refractometry (AFR), which produces an image of the beam’s 2D spatial profile that contains intensity contours corresponding to curves of constant refraction angle. Further analysis is required to reconstruct the underlying line-integrated electron density. Most prior efforts to calculate density from AFR data have been limited to 1D analysis or forward-fitting techniques. Here, in this paper, we detail the use of a fast-marching Eikonal solver to directly invert AFR data and obtain the full 2D line-integrated electron density. The analysis method is first verified with synthetic data and then applied to experimental measurements of single and colliding plasma plumes collected at the OMEGA EP Laser Facility. The calculated densities agree with 1D results and are shown to be consistent with the original AFR measurements via forward modeling. We also discuss ways to improve the precision of this technique.

McCluskey, B. [Princeton Univ., NJ (United States)↗

Coordinated Integration of Renewable Generation and Small Modular Reactors in Puerto Rico – an Initial Study

With a growing interest and awareness to support clean and sustainable sources of energy, several countries have ambitious plans to significantly increase the penetration of renewable energy in the grid. However, the sources of renewable energy, such as solar and wind, are highly intermittent and therefore can pose additional challenges to maintain reliable system operations; one such challenge being flexibility requirement. This paper addresses the concerns of increasing flexibility needs with high renewable penetration, and also study the coordinated integration of nuclear small modular reactor and inverter-based renewable generation sources in a system to achieve high levels of carbon-free and sustainable energy. In this paper, balancing reserve and short-term flexibility requirements were considered for the analysis purpose. Also, methodology was developed to calculate metrics for calculating short-term flexibility requirements in the time-scale of hours. Small modular reactors are considered as potential sources of generation flexibility to complement renewables.

Agrawal, Urmila↗

Enhancing Cyber Resilience of Networked Microgrids using Vertical Federated Reinforcement Learning

This paper presents a novel federated reinforcement learning (Fed-RL) methodology to inject sufficient resiliency into the operations of the network of microgrids. We consider adversarial actions to the voltage and power control loop reference signals at the grid forming (GFM) inverters in the microgrids which are essential to integrate renewable resources. Therefore, we formulate a resilient reinforcement learning training setup that uses these adversarial injections to generate episodic trajectories and train the RL agents to alleviate their impact on performance. To circumvent the concerns about data-sharing and privacy for different owners of the microgrids in the networked setting, we bring in the aspects of the federated operation to propose novel Fed-RL algorithms. As the dynamics of each microgrid are coupled due to electrical interlinks, the conventional federated RL approaches using decoupled independent environments are not applicable, which leads us to propose a multi-agent vertically federated variation of actor-critic algorithms, namely federated soft actor-critic (FedSAC). We have performed numerical simulations on an IEEE 123-bus benchmark test feeder with three microgrids by creating a customized simulation setup by encapsulating the microgrid dynamic simulations in GridLAB-D/HELICS co-simulation platform with the OpenAI Gym environment and validated the proposed resilient and secured learning methodology.

Artificial Intelligence (AI), reinforcement learni↗

Large Scale Field Demonstration Evaluation Plan

This Evaluation Plan defines practical, commissioning-oriented test protocols for in-field assessment of grid-forming (GFM) inverter-based resources (IBRs) deployed under the UNIFI Consortium Field Demonstration. The demonstration’s overarching objective is to validate multi vendor GFM technologies at impactful unit/plant scale, assess interoperability and grid-service performance, and evaluate the applicability of the UNIFI Specifications for Grid-forming Inverter-based Resources in real utility environments, including integration with operational systems and protection schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Distributed Control and Optimization of Virtual Inertia in Power Systems

The integration of renewable energy sources into power grids through inverter-based resources (IBRs) reduces system inertia, leading to faster frequency dynamics and potential grid instability. This paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources during system disturbances, enhancing both system stability and economic performance. Furthermore, we integrate this approach with the traditional inertia placement problem, demonstrating its suitability for existing frameworks. We validate its effectiveness in a 4-bus test system and a two-area 8-bus test system, showcasing its potential for scalable, dynamic inertia management in low-inertia grids.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own.

IBRs↗

Electromagnetic Transient Simulation Algorithms for Evaluation of Large-Scale Extreme Fast Charging Systems (Distribution Grid Models)

The distribution and transmission grids are observing an increased penetration of power electronics in loads and generations. For example, there is increasing interest in integrating in extreme fast charging (XFC) systems for fast charging of electrical vehicles. As these systems are integrated, developing high-fidelity electromagnetic transient model of XFC systems in distribution grids and evaluating their interactions with the power grid would be of significant interest. This model will be utilized for design of XFC systems, to identify upgrades in distribution and/or transmission grids, for planning purposes by transmission planners or operators or owners, among others. It can also be utilized in operations for improved reliable performance of the grid and/or XFC station. The challenge with simulating these models is the high computational complexity introduced by the large number of states present in the system and the time-step needed to simulate the system. In this paper, advanced simulations algorithms are applied to reduce the computational complexity of simulating large-scale XFC systems. The algorithms include numerical stiffness-based segregation, time constant-based segregation, clustering and aggregation on differential algebraic equations (DAEs), and multi-order integration approaches. While the first three algorithms split the matrix that needs to be inverted from a large matrix to much smaller matrices, the final algorithm reduces the computational burden of applying higher-order integration approaches in the complete system. The comparison made in the previous sentence is with respect to use of homogeneous integration approaches used in conventional electromagnetic transient simulators like power systems computer aided design (PSCAD). The approaches mentioned here have resulted in speed-up of 36x in the simulation of a single distribution system with 15 XFCs.

Debnath, Suman↗

Subhourly Clipping Correction Model Comparison

This work will compare the Allen method and Walker method of accounting for subhourly inverter clipping power losses in hourly PV performance models. The Allen method uses a matrix lookup based on DNI clearness and clipping potential to assign a clipping correction loss at each simulation timestep. The Walker method models the PV DC power input to the inverter as a distribution over the hourly timestep and uses integration over the timestep to determine the amount of clipping that occurs within the timestep. Both these models have been recently implemented in the System Advisor Model's (SAM) open-source code, and will be applied to hourly SURFRAD datasets to analyze the subhourly clipping loss predicted by each model for different system designs and inverter loading conditions. Both models will be compared to "true" 1-minute SURFRAD data simulations to see their accuracy against more accurate 1-minute clipping correction loss predictions. This model comparisons will be investigated in more detail at the PVSC conference in Seattle, Washington June 2024.