Necklace-structured high-harmonic generation for low-divergence, soft x-ray harmonic combs with tunable line spacing

The extreme nonlinear optical process of high-harmonic generation (HHG) makes it possible to map the properties of a laser beam onto a radiating electron wave function and, in turn, onto the emitted x-ray light. Bright HHG beams typically emerge from a longitudinal phased distribution of atomic-scale quantum antennae. Here, we form a transverse necklace-shaped phased array of linearly polarized HHG emitters, where orbital angular momentum conservation allows us to tune the line spacing and divergence properties of extreme ultraviolet and soft x-ray high-harmonic combs. The on-axis HHG emission has extremely low divergence, well below that obtained when using Gaussian driving beams, which further decreases with harmonic order. This work provides a new degree of freedom for the design of harmonic combs—particularly in the soft x-ray regime, where very limited options are available. Such harmonic beams can enable more sensitive probes of the fastest correlated charge and spin dynamics in molecules, nanoparticles, and materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rotation-Enabled 7-Degree of Freedom Seismometer for Geothermal Resource Development. Phase 1 Final Report

Under this Department of Energy (DOE) grant, A-Tech Corporation d.b.a. Applied Technology Associates (ATA), seeks to develop a seven-degree-of-freedom (7-DOF) seismic measurement tool for high-temperature geothermal applications. The Rotational-Enabled 7-DOF Seismometer includes a conventional tri-axial accelerometer, a conventional pressure sensor or hydrophone, and a tri-axial rotational sensor. The rotational sensing capability is novel, based upon ATA's innovative research in rotational sensing technologies. The geothermal industry requires tools for high-precision seismic monitoring of crack formation associated with Enhanced Geothermal System (EGS) stimulation activity. Currently, microseismic monitoring is conducted by deploying many seismic tools at different depth levels along a 'string' within drilled observation wells. Costs per string can be hundreds of thousands of dollars. Processing data from the spatial arrays of linear seismometers allows back-projection of seismic wave states. In contrast, a Rotational-Enabled 7-DOF Seismometer would simultaneously measure p-wave velocity, s-wave velocity, and incident seismic wave direction all from a single point measurement. In addition, the Rotational-Enabled 7-DOF Seismometer will, by its nature, separate p- and s-waves into different data streams, simplifying signal processing and facilitating analysis of seismic source signatures and geological characterization. By adding measurements of three additional degrees-of-freedom at each level and leveraging the information from this new seismic observable, it is likely that an equally accurate picture of subsurface seismic activity could be garnered with fewer levels per hole. The key cost savings would come from better siting of the well due to increased information content and a decrease in the number of confirmation wells drilled, also due to the increase in information per well. Improved seismic tools may also increase knowledge, understanding, and confidence, thus removing some current blocks to feasibility and significantly increasing access to potential geothermal sites. During the Phase 1 effort summarized in this final report, the ATA Team modeled and built two TRL 3 proof-of-concept test units for two competing rotational sensor technologies. The two competing technologies were based on ATA's angular rate and angular displacement measurement technologies; Angular rate: ATA's Magnetohydrodynamic Angular Rate Sensor (Seismic MHD); and Angular displacement: ATA's Low Frequency Improved Torsional Seismometer (LFITS). In order to down-select between these two technologies and formulate a go / no go decision, the ATA Team analyzed and traded scientific performance requirements and market constraints against sensor characteristics and components, acquiring field data where possible to validate the approach and publishing results from these studies of rotational technology capability. Based on the results of Phase 1, the ATA Team finds that the Seismic MHD (SMHD) technology is the best choice for enabling rotational seismometry and significant technical potential exists for micro-seismic monitoring using a downhole 7-DOF device based on the SMHD. Recent technical papers and field data confirm the potential of rotational sensing for seismic mapping, increasing confidence that cost-reduction benefits are achievable for EGS. However, the market for geothermal rotational sensing is small and undeveloped. As a result, this report recommends modifying the Phase 2 plan to focus on prototype development aimed at partnering with early adopters within the geothermal industry and the scientific research community. The highest public benefit will come from development and deployment of a science-grade SMHD rotational seismometer engineered for geothermal downhole conditions and an integrated test tool for downhole measurements at active geothermal test sites.

15 GEOTHERMAL ENERGY↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modular low cost trackerless spectral sensor

A photodiode sensor device and systems. The photodiode sensor device includes a housing portion. The housing portion includes a cylindrical enclosure. A window is disposed at a first end of the housing portion. A filter wheel is within the housing portion. A motor positioned within the housing is adjacent the filter wheel opposite the window. The motor is attached to the filter wheel. A photodiode sensor within the housing portion intermediate the first photodiode sensor and the window. The first photodiode sensor receives filtered light incident on the window and transmit a signal associated with sensed parameters of the filtered light. Also, a hemispherical dome for diffusing the light to a collimating lens has a grating, a focusing lens, and a linear detector array. An exit port transmits light to the collimating lens. The sensor array is opposite the grating for sensing the diffused light.

14 SOLAR ENERGY↗

A Hartree-Fock Application Using UPC++ and the New DArray Library

The Hartree-Fock (HF) method is the fundamental first step for incorporating quantum mechanics into many-electron simulations of atoms and molecules, and it is an important component of computational chemistry toolkits like NWChem. The GTFock code is an HF implementation that, while it does not have all the features in NWChem, represents crucial algorithmic advances that reduce communication and improve load balance by doing an up-front static partitioning of tasks, followed by work stealing whenever necessary. To enable innovations in algorithms and exploit next generation exascale systems, it is crucial to support quantum chemistry codes using expressive and convenient programming models and runtime systems that are also efficient and scalable. Here, this paper presents an HF implementation similar to GTFock using UPC++, a partitioned global address space model that includes flexible communication, asynchronous remote computation, and a powerful multidimensional array library. UPC++ offers runtime features that are useful for HF such as active messages, a rich calculus for array operations, hardware-supported fetch-and-add, and functions for ensuring asynchronous runtime progress. We present a new distributed array abstraction, DArray, that is convenient for the kinds of random-access array updates and linear algebra operations on block-distributed arrays with irregular data ownership. Finally, we analyze the performance of atomic fetch-and-add operations (relevant for load balancing) and runtime attentiveness, then compare various techniques and optimizations for each. Our optimized implementation of HF using UPC++ and the DArrays library shows up to 20% improvement over GTFock with Global Arrays at scales up to 24,000 cores.

97 MATHEMATICS AND COMPUTING↗

Carrier-Envelope Phase Control in Terahertz Pulse Generation Using InAs Ribbon Metasurfaces

Generation of broadband terahertz (THz) pulses with variable polarization and carrier-envelope phase can enable the tailoring of THz beam wavefronts for advanced applications in THz imaging and spectroscopy and for strong THz field optics. While metasurfaces composed of deeply subwavelength THz emitters have recently been demonstrated to define the polarization and spatial profile of the generated THz fields, precise phase control or synthesis of THz pulse waveforms remains a challenging problem. Here, we propose and demonstrate metasurfaces composed of indium arsenide (InAs) nanoscale ribbon arrays capable of generating THz pulses with variable carrier-envelope phase. We show that different THz generation mechanisms, each contributing distinct phases, can be activated in the ribbons, enabling carrier-envelope phase control spanning a range of π over a wide band of frequencies (∼1–3 THz). This is achieved solely through the ribbon array geometry using linearly polarized optical excitation of the ribbons. The arrays enable precise control of the THz phase and amplitude, opening the door to advanced structured THz wavefront synthesis using ultrathin dielectric metasurfaces.

carrier-envelope phase↗

Enhanced focus steering abilities of multi-element therapeutic arrays operating in nonlinear regimes

Steering abilities of a typical HIFU therapeutic array operated in linear and nonlinear regimes were compared using numerical simulation with the 3D Westervelt equation. The array included 256 elements of 1.2 MHz frequency and 6.6 mm diameter distributed in a quasi-random pattern over a spherical shell with a 130 mm aperture and a focal length of 120 mm. In the case of linear focusing, thermal effects are proportional to the intensity level and the criterion for safe array operation is that the intensity in the grating lobes should be less than 10% of the intensity in the main focus. In the case of nonlinear focusing, the heating effect is no longer proportional to intensity; therefore the heat deposition rate was chosen as the relevant metric, using the same 10% threshold for the secondary lobe in comparison with the focal maximum. When steering the focus, the same linearly predicted intensity level at the main focus was maintained by increasing the array power. Numerical simulations of the acoustic field were performed for nonlinear propagation both in water and in tissue. It was shown that for shock-forming conditions in the main focus, the steering range of safe electronic focusing is larger than that for linear propagation conditions. Nonlinear sonication regimes therefore can be used to enlarge tissue volumes that can be sonicated using electronic steering of the focus of HIFU arrays.

42 ENGINEERING↗

Magnetic field directed assembly of superstructures of ferrite-ferroelectric core-shell nanoparticles and studies on magneto-electric interactions

Composites of ferromagnetic and ferroelectric are of interest for studies on mechanical strain mediated magneto-electric (ME) interactions and for useful technologies. Here, we report on magnetic-field-assisted-assembly of barium titanate (BTO)-nickel ferrite (NFO) core-shell particles into linear chains and 2D/3D arrays and measurements of ME effects in such assemblies. First, we synthesized the core-shell nano-particles with 50–600 nm BTO and 10–200 nm NFO by chemical self-assembly by coating the ferroic particles with complementary coupling groups and allowing them to self-assemble in the presence of a catalyst via the “click” reaction. The core-shell structure was confirmed with electron microscopy and scanning probe microscopy. We obtained superstructure of the core-shell particles by subjecting them to a magnetic field gradient that exerts an attractive force on the particles and align them toward the regions of high field strengths. At low particle concentration, linear chains were formed and they evolved into 2D and 3D arrays at high particle concentrations. Magnetoelectric characterization on unassembled films and assembled arrays has been performed through measurements of low-frequency ME voltage coefficient (MEVC) by subjecting the sample to a bias magnetic field and an ac magnetic field. The MEVC is higher for field-assembled samples than for unassembled films and is found to be sensitive to field orientation with a higher MEVC for magnetic fields parallel to the array direction than for magnetic fields perpendicular to the array. A maximum MEVC of 20 mV/cm Oe, one of the highest reported for any bulk nanocomposite, is measured across the array thickness. A model is provided for ME coupling in the superstructures of BTO-NFO particulate composites. First, we estimated the MEVC for a free-standing BTO-NFO core-shell particle and then extended the model to include an array of linear chains of the particles. The theoretical estimates are in qualitative agreement with the data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Protein Arrays for Quantitative Systems Analysis of the Dynamics of Signaling Pathway Interactions

Astronauts and workers in nuclear plants who repeatedly exposed to low doses of ionizing radiation (IR, <10 cGy) are likely to incur specific changes in signal transduction and gene expression in various tissues of their body. Remarkable advances in high throughput genomics and proteomics technologies enable researchers to broaden their focus from examining single gene/protein kinetics to better understanding global gene/protein expression profiling and biological pathway analyses, namely Systems Biology. An ultimate goal of systems biology is to develop dynamic mathematical models of interacting biological systems capable of simulating living systems in a computer. This Glue Grant is to complement Dr. Boothman’s existing DOE grant (No. DE-FG02-06ER64186) entitled “The IGF1/IGF-1R-MAPK-Secretory Clusterin (sCLU) Pathway: Mediator of a Low Dose IR-Inducible Bystander Effect” to develop sensitive and quantitative proteomic technology that suitable for low dose radiobiology researches. An improved version of quantitative protein array platform utilizing linear Quantum dot signaling for systematically measuring protein levels and phosphorylation states for systems biology modeling is presented. The signals are amplified by a confocal laser Quantum dot scanner resulting in ~1000-fold more sensitivity than traditional Western blots and show the good linearity that is impossible for the signals of HRP-amplification. Therefore this improved protein array technology is suitable to detect weak responses of low dose radiation. Software is developed to facilitate the quantitative readout of signaling network activities. Kinetics of EGFRvIII mutant signaling was analyzed to quantify cross-talks between EGFR and other signaling pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subwavelength photonic crystal waveguide in optical systems

An optical system is disclosed. The optical system comprising: a substrate; and a subwavelength photonic crystal waveguide atop the substrate, wherein the subwavelength photonic crystal waveguide comprises a periodic one or two-dimensional array of two or more interleaved dielectric pillars; wherein the periodicity of the one or two-dimensional array is constant, a combination of two or more periods, or random; wherein the one or two-dimensional array is substantially linear or curved; wherein each of the pillars of the one or two-dimensional array is at least one of a triangular prism, a trapezoidal prism, an elliptic cylinder, a cylinder, a tube, a frustum, a pyramid, a trapezoidal prism, and an asymmetric frustum; and wherein each of the pillars of the one or two-dimensional array comprises a solid, liquid, and/or gas. Other embodiments are described and claimed.

Xu, Xiaochuan↗

Parallel programming of an ionic floating-gate memory array for scalable neuromorphic computing

Neuromorphic computers could overcome efficiency bottlenecks inherent to conventional computing through parallel programming and readout of artificial neural network weights in a crossbar memory array. However, selective and linear weight updates and <10-nanoampere read currents are required for learning that surpasses conventional computing efficiency. We introduce an ionic floating-gate memory array based on a polymer redox transistor connected to a conductive-bridge memory (CBM). Selective and linear programming of a redox transistor array is executed in parallel by overcoming the bridging threshold voltage of the CBMs. Synaptic weight readout with currents <10 nanoamperes is achieved by diluting the conductive polymer with an insulator to decrease the conductance. The redox transistors endure >1 billion write-read operations and support >1-megahertz write-read frequencies.

bio-inspired, energy storage (including batteries ↗

Linear fitting of multi-threshold counting data

The present disclosure provides a system and method for efficiently mining multi-threshold measurements acquired using photon counting pixel-array detectors for spectral imaging and diffraction analyses. Images of X-ray intensity as a function of X-ray energy were recorded on a 6 megapixel X-ray photon counting array detector through linear fitting of the measured counts recorded as a function of counting threshold. An analytical model is disclosed for describing the probability density of detected voltage, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Three-parameter fits to the model were independently performed for each pixel in the array for X-ray scattering images acquired for 13.5 keV and 15.0 keV X-ray energies. From the established pixel responses, multi-threshold composite images produced from the sum of 13.5 keV and 15.0 keV data can be analytically separated to recover the monochromatic images through simple linear fitting.

47 OTHER INSTRUMENTATION↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distance calculation methods used in linearization for particle identification in multi-detector arrays

Interest in the influence of the neutron-to-proton (N/Z) degree of freedom on multi-fragmentation has demanded an improvement in the capabilities of multidetector arrays as well as the particle identification methods. Excellent isotopic identification of particles through a linearization analysis is achieved with various algorithms for calculating the distance between a point and a polynomial function. A new Point-to-Curve method of distance determination is introduced. Descriptions of various methods as well as their performances are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivering both sum and difference beam distributions to a planar monopulse antenna array

A planar monopulse radar apparatus includes a planar distribution matrix coupled to a planar antenna array having a linear configuration of antenna elements. The planar distribution matrix is responsive to first and second pluralities of weights applied thereto for providing both sum and difference beam distributions across the antenna array.

42 ENGINEERING↗

ALFA Non-linear Ocean Waves and PTO Control Strategy

Data from Advanced Laboratory and Field Arrays (ALFA) Non-linear Ocean Waves and Power Take-Off (PTO). Control Strategy project conducted at the O.H. Hinsdale Wave Research Laboratory (HWRL) at Oregon State University in 2019/2020. Contains two zip files (ALFANL.zip, ALFANL2.zip) from two phases of testing with data in engineering units and a report detailing the testing. This data collected by HWRL. A readme file in the docs folder explains the data collection and format. Six zip files (foswec-1 to foswec-6) data recorded by the Floating Oscillating Surge Wave Energy Converter (FOSWEC). Data organized by date and time and report describes data. A test report (ALFA Non-linear Ocean Waves Test Report.docx) details the experiments and data recording.