Search NASA⌕ Search

SEARCH · Search NASA

Results for “size measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Theory of the von Weimarn Rules Governing the Average Size of Crystals Precipitated from a Supersaturated Solution

More than 75 years ago, von Weimarn summarized his observations of the dependence of the average crystal size on the initial relative concentration supersaturation prevailing in a solution from which crystals were growing. Since then, his empirically derived rules have become part of the lore of crystal growth. The first of these rules asserts that the average crystal size measured at the end of a crystallization increases as the initial value of the relative supersaturation decreases. The second rule states that for a given crystallization time, the average crystal size passes through a maximum as a function of the initial relative supersaturation. Using a theory of nucleation and growth due to Buyevich and Mansurov, we calculate the average crystal size as a function of the initial relative supersaturation. We confirm the von Weimarn rules for the case where the nucleation rate is proportional to the third power or higher of the relative supersaturation.

Barlow, Douglas A.↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Counting Condensation Nuclei in the Antarctic Ozone Mission

The work done on this grant primarily concerns the measurement of aerosol in the stratosphere from NASA ER-2 aircraft in studies of stratospheric ozone depletion in the northern and southern hemispheres. The ER-2 Condensation Nucleus Counter (CNC) measures the number concentration of particles in the diameter range of approximately 0.01 to 1 micron. The Passive Cavity Aerosol Spectrometer measures size distributions in the 0.17 to 3 micron diameter range. This instrument was upgraded during this grant period to a Focused Cavity Aerosol Spectrometer (FCAS). This upgrade permitted the instrument to measure particles as small as 0.05 micron in diameter. The inlet for the PCAS and FCAS was modified and characterized under this grant so that the modifications to the aerosol due to anisokinetic sampling and heating upon sampling and in transport to the measurement location were accounted for in the data analysis. These measurements permitted observations of particle production in the southern hemisphere winter polar vortex and observation of the impact of denitrification on the number concentration of the aerosol in the denitrified air. In the northern polar vortex, the measurements provided a characterization of the sulfate aerosol. Following the eruption of Mount Pinatubo in 1991, the measurements permitted an accurate characterization of the sulfate aerosol enhancements resulting from the eruption. This led to studies of the impact of heterogeneous chemistry on the partitioning of the partitioning of the reactive nitrogen species and the partitioning of the chlorine reservoir.

Wilson, James Charles↗

Demonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator

Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.

Roussel, Ryan↗

Laboratory realization of relativistic pair-plasma beams

Relativistic electron-positron plasmas are ubiquitous in extreme astrophysical environments such as black-hole and neutron-star magnetospheres, where accretion-powered jets and pulsar winds are expected to be enriched with electron-positron pairs. Their role in the dynamics of such environments is in many cases believed to be fundamental, but their behavior differs significantly from typical electron-ion plasmas due to the matter-antimatter symmetry of the charged components. So far, our experimental inability to produce large yields of positrons in quasi-neutral beams has restricted the understanding of electron-positron pair plasmas to simple numerical and analytical studies, which are rather limited. We present the first experimental results confirming the generation of high-density, quasi-neutral, relativistic electron-positron pair beams using the 440 GeV/c beam at CERN’s Super Proton Synchrotron (SPS) accelerator. Monte Carlo simulations agree well with the experimental data and show that the characteristic scales necessary for collective plasma behavior, such as the Debye length and the collisionless skin depth, are exceeded by the measured size of the produced pair beams. Our work opens up the possibility of directly probing the microphysics of pair plasmas beyond quasi-linear evolution into regimes that are challenging to simulate or measure via astronomical observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Occultation of a Large Star by the Large Plutino (28978) Ixion on 2020 October 13 UTC

We observed the occultation of the star Gaia DR2 4056440205544338944 by (28978) Ixion. The event was observed from two Lowell Observatory sites, using the 4.3 m Lowell Discovery Telescope (LDT), near Happy Jack, AZ, USA, and a 0.32 m telescope co-mounted with the Titan Monitoring telescope on Lowell’s Mars Hill campus in Flagstaff, AZ. The LDT chord, at 44.86 s, was roughly 30% longer than the longest predicted possible chord. Under the assumption of a spherical body, Ixion’s fitted diameter D = 709.6 ± 0.2 km. The LDT light-curve profile was used to place an upper limit on the surface pressure P < 2 μbar on any possible atmosphere of Ixion. At the distance of Ixion, the occulted star had a fitted projected diameter of 19.25 ± 0.3 km assuming uniform disk illumination, giving a stellar angular diameter of 0.675 ± 0.010 mas. Using the Gaia EDR3 parallax of 0.565 mas, the stellar radius is 130{sub −17}{sup +20} R{sub ⊙}. The measured size is consistent with prior spectral classification of this star as a reddened mid-M giant. This is one of only a modest number of M5 III stars to have a directly measured diameter, and is more distant than most.

79 ASTRONOMY AND ASTROPHYSICS↗

Cratering in glasses impacted by debris or micrometeorites

Mechanical strength measurements on five glasses and one glass-ceramic exposed on LDEF revealed no damage exceeding experimental limits of error. The measurement technique subjected less than 5 percent of the sample surface area to stresses above 90 percent of the failure strength. Seven micrometeorite or space debris impacts occurred at locations which were not in that portion of the sample subjected to greater than 90 percent of the applied stress. As a result of this, the impact events on the sample were not detected in the mechanical strength measurements. The physical form and structure of the impact sites was carefully examined to determine the influence of those events upon stress concentration associated with the impact and the resulting mechanical strength. The size of the impact site, insofar as it determines flaw size for fracture purposes, was examined. Surface topography of the impacts reveals that six of the seven sites display impact melting. The classical melt crater structure is surrounded by a zone of fractured glass. Residual stresses arising from shock compression and from cooling of the fused zone cannot be included in the fracture mechanics analyses based on simple flaw size measurements. Strategies for refining estimates of mechanical strength degradation by impact events are presented.

Wiedlocher, David E.↗

Annealing effects in plated-wire memory elements. II - Recrystallization in Permalloy films.

Results of grain-size measurements in Permalloy platings suggest that recrystallization is possible at temperatures as low as 200 C, but that it is an extremely heterogeneous process. No worthwhile correlation was found to exist between observed grain size and magnetic dispersion in samples aged in the temperature range from 180 to 230 C. It is suggested that the magnetic aging which occurs under these conditions may be due to some other diffusion-controlled process than recrystallization; a process such as chemical homogenization is tentatively preferred.

Marquardt, S. J.↗

Physical and Optical/Radiative Characteristics of Small Particles in Tropical Cirrus

Whether cirrus clouds heat or cool the Earth-atmosphere system depends on the relative importance of the cloud shortwave albedo effect and the cloud thermal greenhouse effect. Both an determined by the distribution of ice condensate with cloud particle size. The microphysics instrument package flown aboard the DC-8 In TOGA/COARE included an ice crystal replicator, a 2D Greyscale Cloud Particle Probe and a Forward Scattering Spectrometer Aerosol Probe. In combination. these instruments permitted particle size measurements between 0.5 micrometers and 2.6 mm diameter. Ice crystal replicas were used to validate signals from the electro-optical instruments. Typical results show a prevalence in tropical cirrus clouds of micron-sized particles, in addition to cloud particles that exceed 100 micrometer radius. The mechanism of their formation is growth of (hygroscopic, possibly ocean-derived) aerosol particles along the Kohler curves. The concentration of small particles is higher and less variable in space and time, and their tropospheric residence time is longer, than those of large cloud particles because of lower sedimentation velocities. Small particles shift effective cloud particle radii to sizes much smaller than the mean diameter of the cloud particles. This causes an increase in shortwave reflectivity and IR emissivity. and a decrease in transmissivity. In the cirrus outflow of tropical cyclone Oliver on 8 February, 1993, the reflectivity increases with altitude (decreasing temperature) stronger than does cloud emissivity, yielding enhanced radiative cooling at higher altitudes.

Pueschel, R. F.↗

Multipoint-BAX: a new approach for efficiently tuning particle accelerator emittance via virtual objectives

Abstract Although beam emittance is critical for the performance of high-brightness accelerators, optimization is often time limited as emittance calculations, commonly done via quadrupole scans, are typically slow. Such calculations are a type of multipoint query , i.e. each query requires multiple secondary measurements. Traditional black-box optimizers such as Bayesian optimization are slow and inefficient when dealing with such objectives as they must acquire the full series of measurements, but return only the emittance, with each query. We propose a new information-theoretic algorithm, Multipoint-BAX , for black-box optimization on multipoint queries, which queries and models individual beam-size measurements using techniques from Bayesian Algorithm Execution (BAX). Our method avoids the slow multipoint query on the accelerator by acquiring points through a virtual objective , i.e. calculating the emittance objective from a fast learned model rather than directly from the accelerator. We use Multipoint-BAX to minimize emittance at the Linac Coherent Light Source (LCLS) and the Facility for Advanced Accelerator Experimental Tests II (FACET-II). In simulation, our method is 20× faster and more robust to noise compared to existing methods. In live tests, it matched the hand-tuned emittance at FACET-II and achieved a 24% lower emittance than hand-tuning at LCLS. Our method represents a conceptual shift for optimizing multipoint queries, and we anticipate that it can be readily adapted to similar problems in particle accelerators and other scientific instruments.

43 PARTICLE ACCELERATORS↗

A Moderate Resolution View of the Spectral Absorption of Clouds

Some of the first evidence of a cloud absorption anomaly came from retrievals of cloud droplet size using measured multispectral cloud reflectance and in situ microphysical measurements. It was found that spectra computed from the measured droplet size or, equivalently, effective radius inverted from the reflectance measurements disagreed in such a way that suggested there was more absorption in cloud than predicted by theory. During the past decade new evidence of a cloud absorption anomaly has emerged from broadband solar flux measurements from above and below clouds. Based on these findings new field campaigns were devised to specifically address this problem. The most recent of these, the Atmospheric Radiation Measurement (ARM) Enhanced Shortwave Experiment II (ARESEII), included measurements of upwelling and downwelling moderate resolution (10 nm) solar irradiance spectra from above and below cloud. During this talk we will briefly summarize the advantages and limitations of these spectrally resolved measurements compared to the more standard broadband flux. We will focus on cloudy atmosphere results from the ARESEII field study and compare them to theoretical spectra from three independent models.

Pilewskie, Peter↗

Prenatal exposure to mixtures of persistent endocrine disrupting chemicals and postnatal body size in British girls

Endocrine disrupting chemical (EDC) exposure is ubiquitous. EDC exposure during critical windows of development may interfere with the body's endocrine system, affecting growth. Previous human studies have examined one EDC at a time in relation to infant growth. By studying mixtures, the human experience can be better approximated. We investigated the association of prenatal exposure to persistent EDCs (per- and polyfluoroalkyl substances (PFAS), polychlorinated biphenyls (PCBs), and organochlorine pesticides (OCPs)) as mixtures with postnatal body size among female offspring. We used a sub-sample of the Avon Longitudinal Study of Parents and Children (N = 425), based in the United Kingdom. We quantified 52 EDCs in maternal serum collected during pregnancy. We used Bayesian kernel machine regression with a random intercept to examine the association of prenatal concentrations of EDC mixtures with longitudinal postnatal body size measures for each EDC class separately (PFAS, PCBs, and OCPs) and for all three classes combined. Weight and height measures at 0, 2, 9, and 19 months were obtained by health professionals as part of routine child health surveillance. The mixture representing all three classes combined (31 chemicals) (n = 301) was inversely associated with postnatal body size. Holding all EDCs in the 31-chemical mixture at the 75th percentile compared to the 50th percentile was associated with 0.15 lower weight-for-age z-score (95% credible interval –0.26, –0.03). Weak inverse associations were also seen for height-for-age and body mass index-for-age scores. Furthermore, these results suggest that prenatal exposure to mixtures of persistent EDCs may affect postnatal body size.

59 BASIC BIOLOGICAL SCIENCES↗

SAM II and lidar aerosol profile comparisons during AASE

The NASA Langley Research Center aerosol lidar system was one of several instruments that flew aboard a DC-8 during the Airborne Arctic Stratospheric Expedition. Several of the Stratospheric Aerosol Measurement II (SAM II) altitude profiles of aerosol extinction were close enough in time and space to allow for intercomparison with the lidar measurements of aerosol backscatter. Comparisons between three SAM II 1.0 micron aerosol extinction profiles and analogous profiles inferred from nearly simultaneous airborne lidar measurements are discussed. The other two comparisons show the first near-simultaneous SAM II/lidar measurements of a polar stratospheric cloud (PSC). The comparison made well within the edge of a relatively homogeneous PSC layer was also good, especially using an extinction-to-backscatter model derived from in situ PSC particle size measurements.

Osborn, M. T.↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

18 MHz interferometry of Non-Io-C L-bursts

In order to investigate previous discrepancies in source size measurements, 18-MHz interferometric data of L-bursts from a Non-Io-C storm have been collected during the summer of 1986. Variations noted in the fringe visibility of the Jovian L-bursts indicate that the source size changes in time and that the emission region can sometimes be resolved with a relatively modest baseline. The results suggest that all Jovian source sizes are smaller than 10 arcsec (and are possibly smaller than 0.1 arcmin) and that it is more probable that L-burst emission during a Jovian storm will evolve into S-bursts than that S-bursts will become L-bursts.

Phillips, J. A.↗

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗