Search NASA⌕ Search

SEARCH · Search NASA

Results for “elution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Nano-fabricated size exclusion chromatograph

This poster describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through a microcolumn containing nano-fabricated features will have characteristics elution times that directly correlate to molecular weight.

Nanofluidics microfluidics lab-on-a-chip↗

Nano-fabricated size exclusion chromatograph

This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

nanofluids lab-on-a-chip chromatograph separation↗

Analysis of N-Nitrosodimethylamine and N-Nitrodimethylamine in Groundwater

A method for the analytical determination of N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN) at parts-per-trillion (ppt) concentrations in groundwater is reported. The method uses a solid phase extraction (SPE) cartridge containing 2 g of activated coconut charcoal to extract a 500-mL water sample. NDMA and DMN are eluted from the SPE cartridge using acetone. The acetone is concentrated and brought to a final volume of 1.0 mL, which results in a theoretical 500-fold concentration of the analytes. The extracts are analyzed by gas chromatography (GC) with a nitrogenphosphorous detector (NPD), which is a highly sensitive and relatively inexpensive technique. The measured extraction efficiencies averaged 61 percent for NDMA and 74 percent for DMN. Extraction efficiencies were independent of NDMA and DMN concentrations from 40 to 2000 ppt. Several samples could be extracted then analyzed in a single day with the use of an extraction manifold and GC autosampler. A reporting limit of 10 ppt for NDMA and DMN was achieved. The MDLs for NDMA and DMN were 6.4 and 5.8 ppt, respectively. A typical turn-around time from beginning of extraction to reporting was 4 h. The method avoids the use of halogenated solvents, such as dichloromethane, and subsequent solvent exchange procedures necessary for use of the NPD detector.

Greene, Ben↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

Investigation of Isovaline Enantiomeric Excesses and Other C5 Amino Acids in Carbonaceous Meteorites

The origin of biological homochirality is one of the most perplexing puzzles to understanding the emergence of life on Earth. While many models have been proposed, the only reported non-biologically generated. compounds that show a significant enantiomeric excess are a few amino acids in the CM2 Murchison and Murray meteorites (e.g. Pizzarello and Cronin 2000; Pizzarello et al, 2008). Of these isovaline (alpha-ethyl-alanine) is of particular interest since it is typically abundant in CM2 meteorites, is exceedingly rare in biology, and due to its chemical structure is likely to maintain its primordial D/L ratio. Instead of the gas chromatography-mass spectrometry (GC-MS) technique employed by Pizzarello et al., we have used liquid chromatography-fluorescence detection/time of flight-mass spectrometry (LC-FD/ToF-MS) to study the enantiomeric ratio of isovaline in the CM2 meteorites Murchison and LEW90500 and the CR2 QUE99177. We have placed particular emphasis on understanding the suite of C5 amino acids in these meteorites. In doing so, we have determined that D and L 3-aminopentanoic acid co-elutes with Lisovaline and L-valine under common chromatographic conditions (Glavin and Dworkin 2006) for omicron-phthaldialdehyde/N-acetyl-L-cysteine (OPA/NAC). We have devised a method to separate these compounds and we will report the actual D/ L ratios of isovaline in these meteorites and how they compare to the GC-MS measurements of Pizzarello and co-workers.

Dworkin, Jason P.↗

Centrifugal Adsorption Cartridge System

The centrifugal adsorption cartridge system (CACS) is an apparatus that recovers one or more bioproduct(s) from a dilute aqueous solution or suspension flowing from a bioreactor. The CACS can be used both on Earth in unit gravity and in space in low gravity. The CACS can be connected downstream from the bioreactor; alternatively, it can be connected into a flow loop that includes the bioreactor so that the liquid can be recycled. A centrifugal adsorption cartridge in the CACS (see figure) includes two concentric cylinders with a spiral ramp between them. The volume between the inner and outer cylinders, and between the turns of the spiral ramp is packed with an adsorbent material. The inner cylinder is a sieve tube covered with a gas-permeable, hydrophobic membrane. During operation, the liquid effluent from the bioreactor is introduced at one end of the spiral ramp, which then constrains the liquid to flow along the spiral path through the adsorbent material. The spiral ramp also makes the flow more nearly uniform than it would otherwise be, and it minimizes any channeling other than that of the spiral flow itself. The adsorbent material is formulated to selectively capture the bioproduct(s) of interest. The bioproduct(s) can then be stored in bound form in the cartridge or else eluted from the cartridge. The centrifugal effect of the spiral flow is utilized to remove gas bubbles from the liquid. The centrifugal effect forces the bubbles radially inward, toward and through the membrane of the inner cylinder. The gas-permeable, hydrophobic membrane allows the bubbles to enter the inner cylinder while keeping the liquid out. The bubbles that thus enter the cylinder are vented to the atmosphere. The spacing between the ramps determines rate of flow along the spiral, and thereby affects the air-bubble-removal efficiency. The spacing between the ramps also determines the length of the fluid path through the cartridge adsorbent, and thus affects the bioproduct-capture efficiency of the cartridge. Depending on the application, several cartridges could be connected in a serial or parallel flow arrangement. A parallel arrangement can be used to increase product-capturing and flow capacities while maintaining a low pressure drop. A serial arrangement can be used to obtain high product-capturing capacity; alternatively, series-connected cartridges can be packed with different adsorbents to capture different bioproducts simultaneously.

Gonda, Steve R.↗

Structural Evaluation of Radially Expandable Cardiovascular Stents Encased in a Polyurethane Film

A method of encasing cardiovascular stents with an expandable polyurethane coating has been developed to provide a smooth homogeneous inner wall allowing for a confluent growth of endothelial cells. In this design, the metal wire stent structure is completely covered by the polyurethane film minimizing biocorrosion of the metal (stainless steel or nitinol), and providing a homogeneous surface for surface treatment and incorporation of various eluting drugs to prevent platelet aggregation while supporting endothelialization. The polyurethane surface was treated with a helium plasma for sterilization and promotes growth of cells. The paper details the performance of the coated film to expand with the metal stent up to 225 % during deployment. We present stress/strain behavior of polyurethane films, and subsequent plasma treatment of the surface and the adhesion of the coating to the stent structure upon expansion. A film of less than 25 tm was found to be sufficient for corrosion resistance and flexibility without producing any excess stress on the stent structure. Straining the film to 225 % and plasma modification did not affect the mechanical and surface properties while allowing for improved biocompatibility as determined by the critical surface tension, surface chemistry, and roughness.

Trigwell, Steve↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples

RNA isolation is a ubiquitous need, driven by current emphasis on microarrays and miniaturization. With commercial systems requiring 100,000 to 1,000,000 cells for successful isolation, there is a growing need for a small-footprint, easy-to-use device that can harvest nucleic acids from much smaller cell samples (1,000 to 10,000 cells). The process of extraction of RNA from cell cultures is a complex, multi-step one, and requires timed, asynchronous operations with multiple reagents/buffers. An added complexity is the fragility of RNA (subject to degradation) and its reactivity to surface. A novel, microfluidics-based, integrated cartridge has been developed that can fully automate the complex process of RNA isolation (lyse, capture, and elute RNA) from small cell culture samples. On-cartridge cell lysis is achieved using either reagents or high-strength electric fields made possible by the miniaturized format. Traditionally, silica-based, porous-membrane formats have been used for RNA capture, requiring slow perfusion for effective capture. In this design, high efficiency capture/elution are achieved using a microsphere-based "microfluidized" format. Electrokinetic phenomena are harnessed to actively mix microspheres with the cell lysate and capture/elution buffer, providing important advantages in extraction efficiency, processing time, and operational flexibility. Successful RNA isolation was demonstrated using both suspension (HL-60) and adherent (BHK-21) cells. Novel features associated with this development are twofold. First, novel designs that execute needed processes with improved speed and efficiency were developed. These primarily encompass electric-field-driven lysis of cells. The configurations include electrode-containing constructs, or an "electrode-less" chip design, which is easy to fabricate and mitigates fouling at the electrode surface; and the "fluidized" extraction format based on electrokinetically assisted mixing and contacting of microbeads in a shape-optimized chamber. A secondary proprietary feature is in the particular layout integrating these components to perform the desired operation of RNA isolation. Apart from a novel functional capability, advantages of the innovation include reduced or eliminated use of toxic reagents, and operator-independent extraction of RNA.

Sundaram, Shivshankar↗

Novel End-to-End Molecular Biology Approach for Direct Nanopore 1D cDNA Sequencing of Reverse Transcribed mRNAs Purified from Cell Cultures by the NASA ISS WetLab2 SPM

Continued space bioscience research onboard the International Space Station (ISS) and future long-duration flight missions to the Moon or Mars will require the ability to conduct on-orbit molecular analysis of biological samples independently from Earth. In the last year two new molecular analytic technologies have been installed and the technologies demonstrated onboard the ISS: The Sample Prep Module (SPM) WetLab-2 (WL2) qRT-PCR toolbox and the Oxford Nanopore MinIon Biomolecule Sequencer. Here we describe protocol development and integration into existing ISS technology for end-to-end on-orbit biological sample processing and molecular analysis with real time results generated utilizing only field offline analytic software. For this experiment we isolated primary cells from bone marrow flushes of wild type B6129SF2 mice (Jackson Labs) long bones. The cell isolate was then processed using the SPM to produce total 147nanograms of RNA. The total RNA was purified to only messenger RNA (mRNA) and transferred to Smartcycler Thermocycle ISS kit consumable tube using Eppendorf gel loading pipette tips for further processing. Complementary first strand cDNA was synthesized using OLIGO dT priming followed by addition of SuperScript II Reverse Transcriptase and thermal cycling as per manufacturers instruction. All thermal cycling was conducted using the ISS WetLab-2 Cephid Smarcycler real time thermal cycler. Our protocol takes advantage of mRNAs native poly(A) tail, synthesized in vivo to protect the mRNA from degradation by endonucleases, to eliminate end-prep for adapter ligation. The adapted library is purified using MyOne C1 Streptavidin beads before elution in buffer. The pre-sequencing library is diluted in the loading buffer and injected into the MinIon sample port, drawn into the nanopore window by capillary action, and sequenced using the MinKnown software with local basecalling. The sequencing read produced 34.5 million events and local basecalling produced 117,301 successful reads. NCBI Blast of the data for the mouse genome resulted in 2,462 successful nucleotide collection matches (gene sequences) exceeding 70 homology. These results demonstrate the viability of this novel flight ready end-to-end sample analytic methodology and provide a real time homolog for flight experimentation utilizing supply kits and technologies that have already been demonstrated on ISS.

MinIon↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

Molecular Weight Distribution Analysis of Pyrolysis Oils by Gel Permeation Chromatography

Comprehensive analysis of the molecular weight distribution of raw and catalytic fast pyrolysis oils derived from biomass remains a key technical hurdle to understanding oil quality as it relates to downstream use and multiple methods may be necessary to accurately represent all components present. Here, we report the molecular weight distribution metrics of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) oils as determined by gel permeation chromatography (GPC) combined with UV-diode array (UV), differential refractive index (RI), and multi-angle laser light scattering (MALS) detection. The measured molar mass distributions revealed that FP oil consisted of a higher proportion of larger products relative to the low molecular weight products contained in the CFP oil. GPC/RI and UV methods showed FP oil to have higher weight-average molecular weight (Mw) and number-average molecular weight (Mn) than CFP oil based on elution time. However, GPC/MALS, determined the two oils to have similar overall molecular weight distribution metrics (Mw and Mn) and yielded values significantly higher than those determined by RI and UV detectors relative to external standards. Overall, the use of a multiple detection GPC method could enable a more accurate comparison and determination of true molecular weight metrics of bio-oils.

BIOMASS FUELS↗

Rapid isolation of cyclotron-produced gallium-68

Methods for rapid isolation of radionuclides (e.g., 68Ga) produced using a cyclotron and methods for recycling of the parent isotope (e.g., 68Zn) are disclosed. In one version of the method, a solution including a radionuclide (e.g., 68Ga) is created from a target including cations (e.g., 68Zn). The solution including the radionuclide is passed through a first column including a sorbent comprising a hydroxamate resin to adsorb the radionuclide on the sorbent, and the radionuclide is eluted off the sorbent. The cations (e.g., 68Zn) are recovered from a recovery solution that has passed through the first column by passing the recovery solution through a second column including a second sorbent comprising a cation exchange resin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Mineral Separations with Novel Simulated Moving Beds

Lithium is a critical mineral that is widely used in batteries and energy storage applications, making it increasingly important in the next few decades. To meet the growing demand for lithium and secure domestic supply chains, there is a need to exploit unconventional lithium resources. However, utilizing current lithium extraction processes is challenging due to the high salinity in those resources. Thus, it is essential to develop energy-efficient, and less chemical-intensive separation processes that can exploit high-salinity lithium resources. Accordingly, this project aims to design a novel zwitterionic stationary phase and use it to develop a continuous chromatography process to recover LiCl minerals from traditionally unexploited domestic saline resources. The developed zwitterionic stationary phase allows fractionating minerals based on their different sorbent affinities under water elution. A systematically designed continuous process can separate lithium from other minerals, reducing the risk of material fouling and the overall chemical consumption to produce battery-grade lithium. This approach is expected to significantly enhance the efficiency and sustainability of the lithium extraction process while also reducing the environmental impact associated with traditional processes. At the end of the project, the technology will be demonstrated in continuous mode using a simulated moving bed (SMB) to recover >100 g of LiCl from real resource waters. The U.S.-based resources that this project targets for LiCl recovery are formation water, oil-produced water, and geothermal brines, supplied by Standard Lithium Ltd. and Shell Inc, respectively.

critical minerals↗

Tank Side Cesium Removal System Project and Technology Maturation Program - 20101

Washington River Protection Solutions (WRPS) is the Tank Operating Contractor (TOC) for the U.S. Department of Energy-Office of River Protection (DOE-ORP) on the Hanford Site. The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. WRPS is in the process of designing the Tank Side Cesium Removal (TSCR) system to produce a Low Activity Waste (LAW) feed from existing mixed Hanford tank waste. The LAW will be transferred to the Waste Treatment and Immobilization Plant (WTP) LAW Vitrification Facility, where it will be immobilized in a durable glass waste form for disposal. The TSCR Project demonstrates a tank-side treatment system for providing feed to the WTP LAW Vitrification Facility. This system removes undissolved solids and cesium from tank waste supernatant using non-elutable ion exchange media to meet the applicable waste acceptance criteria for the WTP. In support of the project, technology testing has been performed to answer design questions and reduce risk. The project scope and technology testing approach are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mark-18A Target Material Recovery Program: Initial Hot Startup

The Savannah River National Laboratory (SRNL) has been tasked by the National Nuclear Security Administration to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The Mk-18A targets were manufactured with Pu-242 then irradiated under high neutron flux in K-Reactor at the SRS from 1968 to 1978. The sixty-five Mk-18A targets are currently stored in the SRS L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The original targets were manufactured with varying quantities of Pu-242, ranging from 5.2 grams to 121.5 grams. Taking a graded approach to process start up, the lowest loaded target (FT-80-03) was selected as the first target to be received and processed at SRNL. As operational experience and knowledge is gained from processing targets, higher loaded targets will be selected for processing to increase the quantities of valuable isotopes recovered. Due to dose concerns, the receipt and processing of the Mk-18A targets is performed in the SRNL Shielded Cells Facility. The targets are stored in a double J-can confinement in the L-Area Basin. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets are loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 length) are then processed one at a time through the following processes: caustic dissolution and filtration, acidic dissolution and filtration, elutable Reillex anion exchange, diglycolamide (DGA) resin extraction, and DGA calcination. This processing results in two product streams. The first is an aqueous plutonium solution which is removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide product containing the Am and Cm as well as other lanthanide fission products which is removed from the shielded cells using a bagless transfer system. Both materials are packaged for shipment to Oak Ridge National Laboratory (ORNL). This paper will discuss the operating experience, lessons learned, and results from initial process hot startup.

Armstrong, Christopher [Savannah River National La↗