Slot-Height Measuring System

Height displayed as function of position. Slot-depth measuring system uses spring-loaded transducer to measure slot depth and wheel-driven rotary optical encoder to measure position along slot. An x-y recorder plots depth vs. position.

Clarke, Alan D.↗

Advanced high frequency partial discharge measuring system

This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.

Karady, George G.↗

Two-Color Laser Speckle Shift Strain Measurement System

A two color laser speckle shift strain measurement system based on the technique of Yamaguchi was designed. The dual wavelength light output from an Argon Ion laser was coupled into two separate single-mode optical fibers (patchcords). The output of the patchcords is incident on the test specimen (here a structural fiber). Strain on the fiber, in one direction, is produced using an Instron 4502. Shifting interference patterns or speckle patterns will be detected at real-time rates using 2 CCD cameras with image processing performed by a hardware correlator. Strain detected in fibers with diameters from 21 microns to 143 microns is expected to be resolved to 15 mu epsilon. This system was designed to be compact and robust and does not require surface preparation of the structural fibers.

Tuma, Margaret L.↗

Self-organizing map (SOM) of space acceleration measurement system (SAMS) data

In this paper, space acceleration measurement system (SAMS) data have been classified using self-organizing map (SOM) networks without any supervision; i.e., no a priori knowledge is assumed regarding input patterns belonging to a certain class. Input patterns are created on the basis of power spectral densities of SAMS data. Results for SAMS data from STS-50 and STS-57 missions are presented. Following issues are discussed in details: impact of number of neurons, global ordering of SOM weight vectors, effectiveness of a SOM in data classification, and effects of shifting time windows in the generation of input patterns. The concept of 'cascade of SOM networks' is also developed and tested. It has been found that a SOM network can successfully classify SAMS data obtained during STS-50 and STS-57 missions.

STS-57 Shuttle Project↗

Advanced Microgravity Acceleration Measurement Systems (AMAMS) Being Developed

The Advanced Microgravity Acceleration Measurement Systems (AMAMS) project is part of NASA s Instrument Technology Development program to develop advanced sensor systems. The primary focus of the AMAMS project is to develop microelectromechanical systems (MEMS) for acceleration sensor systems to replace existing electromechanical sensor systems presently used to assess relative gravity levels aboard spacecraft. These systems are used to characterize both vehicle and payload responses to low-gravity vibroacoustic environments. The collection of microgravity acceleration data is useful to the microgravity life sciences, microgravity physical sciences, and structural dynamics communities. The inherent advantages of semiconductor-based systems are reduced size, mass, and power consumption, with enhanced long-term calibration stability.

Sicker, Ronald J.↗

The NASA-ER2 meteorological measurement system: Instrumentaion, calibration and intercomparison results

The NASA ER-2 aircraft is used as a platform for high altitude atmospheric missions. The Meteorological Measurement System (MMS) was designed specifically for atmospheric research to provide accurate, fast response, in situ measurements of pressure, temperature, and the three dimensional wind vector. The MMS consists of three subsystems: an air motion sensing system to measure the velocity of the air with respect to the aircraft, a high resolution Inertial Navigation System (INS) to measure the velocity of the aircraft with respect to the Earth, and a Data Acquisition System, to sample, process and record the measured quantities. Details of each of these systems are given. The location of the MMS instrumentation is illustrated. The calibration of the MMS is discussed and results on an intercomparison of MMS measurements, Vaisala radiosonde observation and radar tracking data are given. An illustration of the MMS measurement of vertical wind is given.

Chan, K. Roland↗

Airborne RF Measurement System and Analysis of Representative Flight RF Environment

Environmental radio frequency (RF) data over a broad band of frequencies were needed to evaluate the airspace around several airports. An RF signal measurement system was designed using a spectrum analyzer connected to an aircraft VHF/UHF navigation antenna installed on a small aircraft. This paper presents an overview of the RF measurement system and provides analysis of a sample of RF signal measurement data over a frequency range of 30 MHz to 1000 MHz.

Koppen, Sandra V.↗

LANL MPCL Measurement System Analysis: AMPTEC 630ES Igniter Tester / Ohmmeter

This comprehensive analysis aimed to evaluate the measurement capability of the AMPTEC 630ES Explosive Safety Igniter Tester, a critical tool for organizations engaged in the measurement of High Explosive components and related Electro-Explosive devices. With a history of notable calibration issues involving specific model numbers, the Metrology Program and Calibration Laboratory (MPCL) initiated an extensive Measurement System Analysis. The analysis's primary focus was to thoroughly quantify the various sources of measurement variability intrinsic to the calibration process. It centered on two pivotal aspects: repeatability (the variation observed when the same operator uses the same instrument) and reproducibility (the variation seen when different operators perform measurements). A secondary objective was to determine whether equipment usage and age had any impact on the instrument's performance.

47 OTHER INSTRUMENTATION↗

Advanced optical blade tip clearance measurement system

An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

Ford, M. J.↗

Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection

A fiber-optic sensor system is designed to measure magnetic fields associated with a lightning stroke. Field vector magnitudes are detected and processed for multiple locations. Since physical limitations prevent the sensor elements from being located in close proximity to highly conductive materials such as aluminum, the copper wire sensor elements (3) are located inside a 4-cubic-in. (.66-cubic-cm) plastic housing sensor head and connected to a fiber-optic conversion module by shielded cabling, which is limited to the shortest length feasible. The signal path between the conversion module and the avionics unit which processes the signals are fiber optic, providing enhanced immunity from electromagnetic radiation incident in the vicinity of the measurements. The sensors are passive, lightweight, and much smaller than commercial B-dot sensors in the configuration which measures a three-dimensional magnetic field. The system is expandable, and provides a standard-format output signal for downstream processing. Inside of the sensor head, three small search coils, each having a few turns on a circular form, are mounted orthogonally inside the non-metallic housing. The fiber-optic conversion module comprises three interferometers, one for each search coil. Each interferometer has a high bandwidth optical phase modulator that impresses the signal received from its search coil onto its output. The output of each interferometer travels by fiber optic cable to the avionics unit, and the search coil signal is recovered by an optical phase demodulator. The output of each demodulator is fed to an analog-to-digital converter, whose sampling rate is determined by the maximum expected rate of rise and peak signal magnitude. The output of the digital processor is a faithful reproduction of the coil response to the incident magnetic field. This information is provided in a standard output format on a 50-ohm port that can be connected to any number of data collection and processing instruments and/or systems. The measurement of magnetic fields using fiber-optic signal processing is novel because it eliminates limitations of a traditional B-dot system. These limitations include the distance from the sensor to the measurement device, the potential for the signal to degrade or be corrupted by EMI from lightning, and the size and weight of the sensor and associated plate.

Gurecki, Jay↗

Microgravity Acceleration Measurement System (MAMS) Flight Configuration Verification and Status

The Microgravity Acceleration Measurement System (MAMS) is a precision spaceflight instrument designed to measure and characterize the microgravity environment existing in the US Lab Module of the International Space Station. Both vibratory and quasi-steady triaxial acceleration data are acquired and provided to an Ethernet data link. The MAMS Double Mid-Deck Locker (DMDL) EXPRESS Rack payload meets all the ISS IDD and ICD interface requirements as discussed in the paper which also presents flight configuration illustrations. The overall MAMS sensor and data acquisition performance and verification data are presented in addition to a discussion of the Command and Data Handling features implemented via the ISS, downlink and the GRC Telescience Center displays.

Wagar, William↗

Water vapor measurement system in global atmospheric sampling program, appendix

The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.

Englund, D. R.↗

Electro-optical flight deflection measurement system

This paper describes an electrooptical flight-deflection measurement system (FDMS) developed for use on highly-maneuverable-aircraft-technology (HiMAT) RPV flight research program. The FDMS provides in-flight measurements of the aircraft structural deflections and magnetic-tape recordings for automated data processing. The capabilities and limitations, requirements for installation on an aircraft, analytical considerations, and typical flight data acquired from the HiMAT research program are examined. The flight data indicate that the background light is the major obstacle to acquiring high-quality data and that the relationship between the target displacement and the output of the FDMS is nonlinear; however, the nonlinear effects can be minimized with judicious planning of the installation of the FDMS on the aircraft. Excellent flight deflection data were obtained from both the HiMAT and X-29 A flight research program with very little data lost as a result of encounters with severe background light.

Deangelis, V. Michael↗

The Cryogenic, High-Accuracy, Refraction Measuring System (CHARMS): A New Facility for Cryogenic Infrared through Vacuum Far-Ultraviolet Refractive Index Measurements

The optical designs of future NASA infrared (IR) missions and instruments, such as the James Webb Space Telescope's (JWST) Near-Mixed Camera (NIRCam), will rely on accurate knowledge of the index of refraction of various IR optical materials at cryogenic temperatures. To meet this need, we have developed a Cryogenic, High-Accuracy Refraction Measuring System (CHARMS). In this paper we discuss the completion of the design and construction of CHARMS as well as the engineering details that constrained the final design and hardware implementation. In addition, we will present our first light, cryogenic, IR index of refraction data for LiF, BaF2, and CaF2, and compare our results to previously published data for these materials.

Frey, Bradley J.↗

The development of an air motion measurement system for NASA's Electra aircraft

The development of the Turbulent Air Motion Measurement System (TAMMS), which is to measure dynamical and photochemical processes over a wide range of spatial and temporal scales, is examined. The composition and operation of the TAMMS subsystems, which include (1) fast-response meteorological sensors; (2) a boom/inertial navigation system; (3) baseline meteorological sensors; (4) an analog/digital interface; (5) control and data acquisition; and (6) data/reduction and spectral analysis software, are described. The planned flight testing and calibration of the TAMMS are discussed. The TAMMS platform wil be able to estimate the turbulent fluxes of heat, moisture, momentum, and any chemical species for which fast-response instrumentation is available.

Ritter, J.↗

Two-stage gas measurement system

A quick-response, real-time gaseous measurement system allows for the continuous sampling of a low pressure gaseous environment. A sample of test gas from the low pressure gaseous environment is continuously extracted and pumped to a structural tee joint which is open to the atmosphere at one end to maintain the test gas at a constant pressure. The structural tee joint communicates at the other end with a heater for maintaining the test gas at a constant temperature. From the heater, the test gas is sent to a sensor which develops a voltage that is proportional to the partial pressure of the gaseous component to be measured in the test gas, a constant flow rate of test gas being provided through the heater and sensor. Since test gas pressure, temperature, and flow rate are being held constant, changes in sensor voltage are attributable only to changes in the concentration of the measured gas component.

Sprinkle, Danny R.↗