Search NASA⌕ Search

SEARCH · Search NASA

Results for “microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Novel Method for Domestic Stable Isotope Production

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species ( 35 Cl- and 37 Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗

Advancements in Heat Transfer and Fluid Mechanics (Fundamentals and Applications)

Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles. Advancements in heat transfer and fluid mechanics have significantly enhanced these systems, driving progress in associated market sectors. For instance, evaporator and condenser coils are essential for optimizing vapor compression cycles in building equipment. Heat pumps used for space and water heating constitute a major share of building systems, with microchannel heat exchanger technology at the forefront of these innovations. It is worth mentioning that advancements in heat transfer and fluid mechanics significantly alleviate the challenge of designing energy-efficient building equipment. The development of research techniques has contributed significantly to the advancement of science; for example, in the experimental field, non-intrusive measurement techniques such as Particle Image Velocimetry (PIV) are now capable of resolving flow behavior in a 3D format for different length and time scales.

42 ENGINEERING↗

Effect of Preparation Conditions of Fe@SiO2 Catalyst on Its Structure Using High-Pressure Activity Studies in a 3D-Printed SS Microreactor

Fischer–Tropsch synthesis (FTS) in a 3D-printed stainless steel (SS) microchannel microreactor was investigated using Fe@SiO2 catalysts. The catalysts were prepared by two different techniques: one pot (OP) and autoclave (AC). The mesoporous structure of the two catalysts, Fe@SiO2 (OP) and Fe@SiO2 (AC), ensured a large contact area between the reactants and the catalyst. They were characterized by N2 physisorption, H2 temperature-programmed reduction (H2-TPR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron microscopy (XPS), and thermogravimetric analysis–differential scanning calorimetry (TGA-DSC) techniques. The AC catalyst had a clear core–shell structure and showed a much greater surface area than that prepared by the OP method. The activities of the catalysts in terms of FTS were studied in the 200–350 °C temperature range at 20-bar pressure with a H2/CO molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher selectivity and higher CO conversion to olefins than Fe@SiO2 (OP). Stability studies of both catalysts were carried out for 30 h at 320 °C at 20 bar with a feed gas molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher stability and yielded consistent CO conversion compared to the Fe@SiO2 (OP) catalyst.

Biochemistry & Molecular Biology↗

Negative affinity X-ray photocathodes

A new X-ray image intensifier is described. The device should eventually have a quantum efficiency which is an order of magnitude greater than that of presently available high spatial resolution X-ray detectors, such as microchannel plates. The new intesifier is based upon a GaAs crystal photocathode which is activated to achieve negative electron affinity. Details concerning the detector concept are discussed together with the theoretical relations involved, X-ray data, and optical data.

Vanspeybroeck, L.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Two-dimensional photon detector

Device incorporates set of cascaded microchannel-array plates in proximity focus with two sets of mutually-orthogonal linear anodes. Technique allows data from N x M picture elements to be recorded with only N + M amplifiers.

Timothy, J. G.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

Spectroscopic survey of the far-ultraviolet /1160-1700 A/ emissions of Capella

A far-ultraviolet spectral survey of Capella (Alpha Aur, G5 III + G0 III) has been obtained using a highly sensitive rocketborne spectrograph with a microchannel plate detector. The spectral distribution is very similar to that of the sun; however, if the line surface fluxes are due to the primary (G5 III), then, except for Ly-alpha, they are about an order of magnitude greater than those of the quiet sun

Vitz, R. C.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

A rocket observation of the far-ultraviolet spectrum of Saturn

Far-ultraviolet (1160-1750 A) spectra of the Saturnian disk and the ring system have been obtained by using a very sensitive rocket-borne spectrograph with a microchannel plate detector. The use of two apertures of different diameter in the telescope focal plane permitted the separation of the contribution of the planetary disk from that of the rings. H I lambda 1216 was the only atomic spectral line emission detected in the planet and the rings. A weak signal from the disk between 1300 A and 1500 A was observed. Geometric disk albedos, averaged over 50 A, were determined from 1500 A to 1700 A. Measurements of the ring reflectivity longward of 1650 A are compatible with H2O frost but not NH3 frost.

Weiser, H.↗

Crossed grid anode and its image partitioning

Measurements on an imaging crossed grid anode following a pair of microchannel plates indicate fast charge propagation via wire-to-wire capacitances, suggesting a temporal resolution of 100 ns. A figure of merit for partitioned systems has been suggested that provides an estimate of the position uncertainty of photoelectrons in the image plane of an anode. Solutions for two-, three-, and four-amplifier position algorithms are given, and basic system requirements are discussed.

Knapp, G.↗

Time-of-flight technique for particle identification at energies from 2 to 400 keV/nucleon

The time of flight technique for particle identification was extended to 2 keV/nucleon and the size of the start-time detector was reduced considerably by the use of carbon foils of few micrograms/cm square in thickness combined with microchannel plates for detecting secondary electrons. Time of flight telescopes incorporating this start-time device were used to measure the stopping power of a number of low energy heavy ions in thin carbon foils and the charge states of these ions emerging from such foils. Applications for the detection and identification of low energy interplanetary and magnetospheric particles are suggested.

Gloeckler, G.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗