Search NASASearch

SEARCH · Search NASA

Results for “Design and Construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,668 records · Page 13

Operando neutron radiography validates a parameter-free transport–kinetics model for thick solid-state battery cathodes

Tortuosity-weighted interfacial flux for lithium (TWIF-Li) predicts through-thickness Li gradients in thick composite all-solid-state cathodes without fitted parameters. Image-derived microstructures, GITT-derived concentration-dependent solid diffusion, and tortuosity-weighted interfacial kinetics reproduce operando neutron radiography across practical rates, delivering transferable design rules to suppress transport-limited reaction fronts.

Adam, Andre [ORNL] (ORCID:0000000245023033)

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Evaluating Polymer Properties with Different Additives for Carbon Capture and Other Applications

Anthropogenic climate change is one of this generation’s most pressing concerns, with the potential to completely alter the delicate balance we’ve struck with nature. Already, global temperatures have risen 1.29°C, leading to disrupted weather systems, extinctions, increased risks of wildfires, and sea level rise, to name a few effects. Carbon dioxide emission from the combustion of fossil fuels and other industrial activity is a large driver of this phenomenon, as it absorbs heat before it can be radiated away from Earth, trapping it. Carbon dioxide has reached unprecedented levels in our atmosphere, showing a 50% increase from preindustrial averages to a whopping 430 ppm. Thus, reducing the amount of carbon dioxide via carbon capture technology is an important endeavor that serves to benefit everyone. The Microencapsulated CO 2 Sorbent (MECS) team at Lawrence Livermore National Laboratory (LLNL) has turned to microencapsulation to approach this endeavor. Microcapsules provide an attractive approach to carbon capture, combining large surface areas for more efficient mass transfer, regenerative abilities, reduced solvent loss, and improved handling. Additionally, while existing carbon capture technology relies on industrial plants, capsules could present a modular approach to carbon capture, reducing the need for extensive physical infrastructure. The MECS team’s design consists of a polymer membrane that contains a liquid carbon sequestering sorbent, aqueous sodium carbonate. The carbon capturing reaction occurs in three distinct steps, the first of which is the dissolution of carbon dioxide into the sorbent solution and its conversion into carbonic acid (H 2 CO 3 ), shown in equations 1 and 2 respectively. Because this step hinges upon the ability of carbon dioxide to reach the solution inside the capsule, it is necessary that the microcapsule shell is permeable to carbon dioxide gas. The MECS team produces these microcapsules using the in-air droplet encapsulation apparatus (IDEA) shown in figure 1, which can produce uniform micron-scale droplets at speeds much faster than traditional single-dispersal microfluidic-based techniques. The IDEA Is 100 times faster than these current techniques and can reach up to 1000 times their speed when incorporating a multi-nozzle design. Additionally, because droplets are produced in-air via vibration, IDEA can decrease post-processing times and material waste by 99% and can fabricate microgels that are 10 to 100 times more viscous than can be produced via traditional microfluidics. While this design represents a breakthrough in the throughput, efficiency, and tunability of microcapsule production, it imposes a major constraint on the microcapsule curing process. Because microcapsule shells are crosslinked with UV light while falling 30 cm through the air, this gives them a reaction window of approximately 0.2 seconds. Thus, the system and shell formulations must be optimized such that the shells can be fully crosslinked within this very narrow window, prompting investigations into curing behavior.

36 MATERIALS SCIENCE

High-Intensity UV Exposure for the Rapid Screening of Silicon Photovoltaic Architectures

Advanced Si photovoltaic architectures incorporate different materials and processing pathways that influence degradation modes. Ultraviolet-induced degradation (UVID) is an understudied degradation mode for advanced cell architectures and is of increasing concern to industry due to growing adoption of UV-transparent encapsulation and bifacial technologies. In order to adopt new and evolving technologies confidently, novel component materials and processing techniques must be evaluated and designed for long-term stability, in addition to the conventional design focus on efficiency. In this work, a study protocol framework is presented for the rapid screening of unencapsulated devices against UVID. Unencapsulated passivated emitter rear contact (PERC) and tunnel oxide passivated contact (TOPCon) devices were aged under different UV irradiance intensities and measured via conventional nondestructive electrical characterization methods to assess performance degradation. Based on the results, protocol efficacy and recommendations for further study are discussed. As a result, this work is part of a broader effort to develop rapid screening processes that cut across architectures and exposure conditions to aid module manufacturers in vetting new materials choices for long-term stability.

Accelerated exposure

AUTOIGNITION DELAY TIMES FOR REFORMATE GAS MIXTURES FROM METHANE GAS ENGINES

Methane slip is a prominent issue in natural gas reciprocating engines that are used in transportation and marine applications. The incomplete combustion that results in methane slip can be resolved with the introduction of hydrogen within the combustion mixture to improve methane oxidation and further enable combustion within the engine crevices where methane has previously remained unreacted. Steam methane reforming (SMR) is a common method used to produce hydrogen and can be used to design an onboard device to reduce methane slip from reciprocating engines. The development of this reformer device requires the validation of high-fidelity chemical kinetic models at the low temperatures of the crevice volumes of these engines. In this work, auto-ignition data is obtained using a shock tube at lean (φ—0.714 or λ—1.4) and stoichiometric (φ, λ = 1) equivalence ratios spanning a temperature range of 1042–1234 K at the 80-bar operating pressure of the test engine. Blends of methane, hydrogen, and reformate products from the SMR reaction are shock-heated in synthetic air, with the ignition delay time measured using an OH* chemiluminescence detector at 310 nm and a CH* detector at 430 nm. The experimental results are compared to several state-of-the-art chemical kinetic mechanisms from the literature. In general, most of the mechanisms show very good agreement with experiments at higher temperatures, with simulation results showing little deviation from experiments at lower temperatures. A sensitivity analysis was conducted, and the results reveal that the reaction H2 + CH3O2 = H + CH3O2H has a very significant role in determining low-temperature ignition delay times (IDTs) of SMR mixtures. These findings provide valuable insights into the chemical kinetics governing methane reformate combustion and contribute to the optimization of onboard reformer designs aimed at mitigating methane slip in natural gas-fueled engines.

Fraze, Matthew

Physicochemical and biological characterization of a bispecific antibody in a CrossMab/KIH format that targets EGFR and VEGF-A

Introduction Bispecific antibodies (BsAbs) are a class of antibody therapeutics engineered in various molecular formats to bind two distinct antigens and potentially mediate multiple biological effects. These molecular formats are tailored to mediate specific mechanisms of action and possess unique physicochemical and biological properties that are necessary to assure product quality. In ovarian cancer (OC), both EGFR- and VEGF-A-mediated signaling pathways are often upregulated and cooperate to promote tumor growth and angiogenesis. Thus, inhibiting of EGFR- and VEGF-A pathways with a BsAb may provide synergistic anti-tumor activity. Methods Using publicly available sequences and applying immunoglobulin domain crossover (CrossMab) and knobs-into-holes (KIH) technologies, we generated a BsAb to simultaneously bind EGFR and VEGF-A (designated as anti-EGFR/VEGF-A BsAb). This BsAb served as a model for physiochemical and biological characterization of quality attributes that would be critical for the BsAb’s mechanisms of action. Our goal was to gain fundamental insights into BsAbs designed to target a receptor with one arm and a soluble ligand with the other, to support bioassay development and inform quality control strategies. Results Our data demonstrated that the CrossMab/KIH platform successfully produced a correctly assembled BsAb during cell culture. Characterization confirmed that the anti-EGFR/VEGF-A BsAb bound both EGFR and VEGF-A with comparable activity and affinity to the respective parental monoclonal antibodies. Functionally, the BsAb disrupted both EGF/EGFR and VEGF-A/VEGFR2 signaling pathways in OC and human umbilical vein endothelial cell (HUVEC) models. Furthermore, the BsAb effectively blocked angiogenic signaling driven by VEGF-A secreted from OC cells in a paracrine manner. Discussion Based on the combinatorial mechanism of action and our characterization findings, we concluded that two or more bioassays may be needed to accurately assess the activity of both arms of this type of BsAb.

Immunology

Programmable Digital Devices used in Advanced Reactors

This paper introduces the concepts of common cause failure, diversity, and defense-in-depth used by the nuclear industry to analyze resilience in reactors. A survey of publicly traded and private companies building advanced reactors and their licensing status is presented. Safety and non-safety systems found in the NuScale Power design are summarized and the likely hardware and software categories used by those systems are enumerated. The importance of industry partners is highlighted. This paper also identifies an alternate path forward without industry partners to advance the knowledge needed to use artificial intelligence to analyze HBOMs and SBOMs to better understand reactor resiliency.

cybersecurity

Nanoscopic Imaging of Self-Propelled Ultrasmall Catalytic Nanomotors

Ultrasmall nanomotors (<100 nm) are highly desirable nanomachines for their size-specific advantages over their larger counterparts in applications spanning nanomedicine, directed assembly, active sensing, and environmental remediation. While there are extensive studies on motors larger than 100 nm, the design and understanding of ultrasmall nanomotors have been scant due to the lack of high-resolution imaging of their propelled motions with orientation and shape details resolved. Here, we report the imaging of the propelled motions of catalytically powered ultrasmall nanomotors─hundreds of them─at the nanometer resolution using liquid-phase transmission electron microscopy. These nanomotors are Pt nanoparticles of asymmetric shapes (“tadpoles” and “boomerangs”), which are colloidally synthesized and observed to be fueled by the catalyzed decomposition of NaBH4 in solution. Statistical analysis of the orientation and position trajectories of fueled and unfueled motors, coupled with finite element simulation, reveals that the shape asymmetry alone is sufficient to induce local chemical concentration gradient and self-diffusiophoresis to act against random Brownian motion. Our work elucidates the colloidal design and fundamental forces involved in the motions of ultrasmall nanomotors, which hold promise as active nanomachines to perform tasks in confined environments such as drug delivery and chemical sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation

Effect of spacer grids on high-burnup fuel fragmentation, relocation, and dispersal

Increasing the fuel burnup limit in light-water reactors to improve fuel cycle economics requires a strong technical foundation. Experimental observations from the Halden and Studsvik programs have revealed severe fuel fragmentation during loss-of-coolant accident (LOCA) conditions, highlighting the need for additional technical evaluation. Consequently, further LOCA test data are needed to complement existing findings and improve the understanding of fuel fragmentation, relocation, and dispersal (FFRD) behavior. Oak Ridge National Laboratory’s Severe Accident Test Station has played a significant role in advancing the understanding of high-burnup fuel fragmentation, relocation, and dispersal phenomena. One remaining gap in the available experimental database is the effect of fuel assembly structural features on cladding deformation behavior during a LOCA, and more specifically, their impact on the fuel’s ability to fragment, relocate, and disperse. Recent analyses using the BISON fuel performance code suggest that cladding deformation near grid spacers will remain below the 3% threshold that has been reported in the NRC Research Information Letter, indicating that the cladding could remain mechanically constrained during the LOCA event. This paper builds upon the BISON analyses to design and conduct a series of out-of-cell tests aimed at further evaluating cladding deformation in and around grid spacers. In addition, these tests were used to assess local cladding temperature conditions and compare them against analytical predictions in order to better replicate expected in-reactor behavior. Finally, an in-cell high-burnup LOCA test was designed and performed to evaluate the effects of a grid spacer, or cladding restraint, on fuel fragmentation, relocation, and dispersal susceptibility. The high-burnup test results differed from those of historical LOCA experiments, with a recorded rupture temperature of 861°C. Two ballooned regions and corresponding rupture openings were observed, with rupture widths of approximately 0.64 mm for both ruptures and rupture lengths of 4.8 mm and 5.6 mm, respectively.

Capps, Nathan [ORNL]

Monitoring Depolymerization in Mesopores Using Dynamic Properties of Polymeric Melt Accessed via Dielectric Spectroscopy

Traditional design principles for heterogeneous catalysis guide the use of catalytic particles with mesosized (∼2–50 nm) pores to increase the number of surface-active sites by way of an increased surface area. However, the entry of long-chain polymers into such pores may be significantly limited by the size and entanglement of polymers in the melt state, thereby decreasing the number of accessible sites. Assessment of catalyst performance from traditional reactor-based studies averages over intrapore reaction events as well as reactions on the surface of a particle, resulting in an inability to distinguish between differences in site accessibility and activity. Techniques that assess the intrapore performance can inform the design of future heterogeneous catalysts for polymer upcycling. In this work, we demonstrate the use of broadband dielectric spectroscopy to monitor depolymerization of a polymer melt within mesopores via changes in the segmental relaxation time scale of amorphous polymer chains. In particular, we highlight the use of an anodic aluminum oxide (AAO) membrane as a readily available model for catalyst pores with a well-characterized pore morphology. The decrease in the segmental relaxation (α-relaxation) time of the melt with increasing chain scission emerges as a measure of the extent of polymer deconstruction inside mesopores. To demonstrate the utility of this technique, we demonstrate the decomposition of two commercial poly(propylene carbonate) polymers with different decomposition rates within mesopores. As the polymers depolymerize, their segmental relaxation time decreases as the molecular weight decreases (as predicted by the Fox–Flory equation). The BDS-measured change in segmental relaxation time mirrors the expected trend based on change in molecular weight measured by size exclusion chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Validation Data for Benchmarking Wire Arc Additive Manufacturing Process Simulations

Residual stresses cause geometric distortion and affect mechanical performance of additively manufactured structures, yet they are notoriously difficult to assess and predict. Distortion (warpage) can drive parts outside dimensional tolerance limits, leading to part rejection or rework. For parts that meet tolerance, locked-in residual stress fields can affect structural integrity during operation, particularly subcritical cracking by fatigue, creep, or corrosion. This work develops benchmark data for a common additive manufacturing process (Wire Arc Additive Manufacturing) that can be applied for calibration and validation of physical process models that predict residual stress fields. The work includes design of two different samples of differing geometry, detailed manufacturing records for a set of physical samples, and an extensive set of residual stress measurement data developed using two diverse techniques (the contour method and neutron diffraction). An initial application of the work is also reported, where a modeling challenge was issued to secure residual stress model predictions from two independent laboratories that were blind to residual stress measurement data. These initial blind residual stress predictions show significant discrepancies relative to the measurement data, illustrating the potential value of the underlying validation data. An open repository for this work, including the sample designs, manufacturing process records, and the residual stress data, is also provided for future application in non-blind validation efforts.

36 MATERIALS SCIENCE

Development of Novel Combustion Codes for Supercritical CO2 Combustion: Cooperative Research and Development Final Report, CRADA Number CRD-20-17182

The Allam-Fetvedt Cycle, a novel supercritical CO2 (sCO2) power cycle developed by 8 Rivers Capital, LLC, generates low-cost power from fossil fuels while capturing combustion-CO2. This cycle employs high-temperature oxy-combustion using sCO2 as the working fluid, leading to a challenging environment for materials. The most critical component for reliable deployment of this technology is the combustor-turbine interface. In the proposed partnership between NREL and 8 Rivers, we will develop a simulation-based tool to provide key design inputs for defining the materials and geometries required in this critical area.

09 BIOMASS FUELS

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Interface-induced fast Li+ transport in mixed ionic–electronic conductors

Interfacial instability between lithium metal and solid-state electrolytes limits the performance of all-solid-state lithium metal batteries (ASSLBs), leading to parasitic reactions, non-uniform Li+ flux, and dendrite growth. Here, we develop a composite interlayer composed of the anti-perovskite Li2OHCl0.75Br0.25 (AP) and carbon nanotubes (CNTs) to enhance both interfacial stability and ionic transport. The AP–CNT interlayer exhibits enhanced Li+ conductivity arising from interfacial electron transfer from AP to CNTs, which generates a built-in electric field that facilitates Li+ migration. Lithium symmetric cells incorporating this interlayer achieve a high critical current density of 2.4 mA cm−2 at 55 °C. This design integrates chemical robustness with coupled ion–electron transport, offering a generalizable strategy for safe, dendrite-free, and high-performance ASSLBs.

He, Chenche

Semi-Transparent Perovskite Solar Cells in a Stacked Tandem Module: Cooperative Research and Development Final Report, CRADA Number CRD-19-00810

This project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, anti-reflection layer composition and deposition process, and cell to module integration processes. Modification 5: The proposed project seeks to develop device design, materials composition, and processing tools and parameters to fabricate semi-transparent perovskite solar cells and modules for application in stand-alone products or added to other solar cells in a mechanically-stacked tandem configuration. This technology presents significant advanced manufacturing challenges and opportunities in getting to scale, including development of perovskite inks, scalable perovskite and heterojunction deposition and annealing processes, heterojunction composition, transparent electrode composition and deposition process, passivation layers including in module scribes, anti-reflection layer composition and deposition process, and cell to module integration processes. Advanced metrology and characterization will be performed on perovskite films, cells and module. Furthermore, we will examine module or materials recycling for circular economy considerations. Modifcation 6: Gigahertz frequency microwave pump-probe spectroscopies are highly sensitive to thin film semiconductor photoconductivity of individual and stacks of layers that comprise perovskite solar cells. As such, these techniques will be used to qualify reproducibility and quality correlations during the manufacturing process. Modification 7: Mechanical adhesion of top contacts within perovskite modules significantly impacts the durability of the module when exposed to accelerated degradation testing. The adhesion between the perovskite/transport layer interface and the transport layer/top contact interface are both very sensitive small changes in processing. ALD processing conditions of the transport layer will be tuned to optimize the mechanical adhesion within the perovskite module stack.

14 SOLAR ENERGY