Search NASASearch

SEARCH · Search NASA

Results for “electric drive system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,495 records · Page 13

Integrated Simulation of Weld Residual Stress Evolution and Crack Propagation Using XFEM

Nuclear power plant components operate in environments that promote multiple degradation mecha- nisms, several of which involve crack initiation and growth. An ongoing effort in the U.S. Department of Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program is developing a general capability within the Multiphysics Object Oriented Simulation Environment (MOOSE) framework for simulating three-dimensional crack growth under a range of driving conditions, including fatigue, stress corrosion cracking (SCC), brittle fracture, and stress-relaxation cracking. This report demonstrates an end-to-end workflow that uses this capability to model weld-residual-stress-driven SCC in the J-groove weld of a pressurized-water reactor control rod drive mechanism penetration in the vessel head. The workflow consists of a thermomechanical welding simulation with temperature-dependent plasticity, followed by cooldown to ambient conditions, and a restart of the simulation using the MOOSE extended finite element method (XFEM) module to propagate a three-dimensional crack through the residual stress field. New welding capabilities were developed to properly initialize newly activated elements in the weld region, and robustness improvements were made to the mesh-based algorithm for defining cutting planes in the 3D XFEM algorithm, allowing it to handle complex crack fronts and stress fields. Together these advances allowed the simulated SCC crack to grow from an initial elliptical flaw in the weld, across the weld, through the tube wall, and almost to the triple point (where the weld, tube, and reactor pressure vessel head intersect) over roughly 36 years of simulated service. These results demonstrate a workflow that can be extended to fully three-dimensional welding simulations and more complex crack interaction problems.

42 - ENGINEERING

Hybrid biophysical systems for atmospheric CO 2 capture

Negative emissions technologies will be essential for limiting anthropogenic global temperature increases to 2 °C in the later years of the 21st century. Carbonic anhydrase (CA) metalloenzymes catalyze the otherwise slow conversion of CO 2 into carbonic acid (H 2 CO 3 ), suggesting their utility in the rapid hydration and downstream capture of dissolved CO 2 in aqueous media for a variety of CO 2 capture methods, such as thermal and pH swings and mineralization. The possibility of driving the rapid capture of CO 2 by catalyzing the CO 2 hydration bottleneck carries real potential for realizing efficient direct air capture (DAC) and direct ocean capture (DOC) systems. However, scaled application of CAs will be dependent on some way of economically sourcing the enzymes at volumes relevant to scaled DAC/DOC operations. In this perspective, we consider the prospect of catalyzing CO 2 hydration using a CA that is bound to the outer membrane of a cyanobacterial host, engineered constructs we call CyCAMs. Coupling extracellular CA expression to a marine, photosynthetic cyanobacterial host results in a CO 2 hydration catalyst that is continuously refreshed during the bacterial growth cycle, without the need for enzyme purification or harvesting steps. In the case of marine cyanobacteria, sunlight and the solutes native to seawater provide the respective energy, nutrients and sources of inorganic carbon essential to maintaining the bacterial population. We consider the potential impact of CA-mediated CO 2 hydration on a variety of DAC processes, with CO 2 mineralization explored as a primary use case.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Ion Transport and Crystal Rotation in Plastic Crystal Electrolytes Under Applied Electric Fields

Organic ionic plastic crystal electrolytes, containing a plastic crystal and lithium salt, offer a potential balance between mechanical and electrochemical properties for solid state lithium-ion battery electrolytes. These electrolytes contain multiple mobile ionic species (three or four), resulting in complex transport mechanisms which have not yet been established. Plastic crystals are defined by long-range positional order and short-range rotational disorder. It is therefore necessary to quantify changes in the local crystal structure of the electrolyte as current flows through it. Herein, we examine the electrochemical properties of pyrrolidinium-based plastic crystal electrolytes containing lithium salt and zwitterion additives, including measurements of current fraction and limiting current. We obtain species-specific insight into electrolyte transport using pulsed-field gradient nuclear magnetic resonance spectroscopy and find that, while the zwitterion additive increases ionic conductivity, it decreases lithium diffusivity with respect to other ionic components. With operando spatiotemporally resolved wide-angle X-ray scattering we observe location-specific crystal rotations due to the passage of ionic current. In conclusion, we posit that reducing energy dissipation due to rotation is essential for using plastic crystal electrolytes in practical applications.

Yap, Kyra M. K. [University of California, Berkele

Electromagnetic Melt Processing: A Pathway to New Additive Manufacturing Technologies for Functional High-Performance Thermoplastics

In this study, we apply the electromagnetic (EM) melt processing of thermoplastics on an innovative EM field-driven powder bed fusion additive manufacturing (AM) concept for high-performance functional parts: Selective Microwave Melting/Sintering (SMM/SMS). This technique leverages the EM susceptibility of carbon nanotube-coated polymer micro-pellets to achieve rapid, localized heating and powder fusion. Thus, selective microwave melting (SMM) was used to fabricate multilayer specimens made of recycled polyphenylene sulfide (rPPS) and carbon nanotubes (CNTs). The resulting SMM specimens exhibited very good interlayer integrity, localized fusion at pellet boundaries, and tolerable residual porosity, indicating effective fusion and acceptable consolidation. CNT-rich interphases were retained after irradiation, generating anisotropic electrically active network pathways and enabling conductivity enhancement at low filler content. At only 1.0 wt% CNT, the specimens exhibited electrical conductivity approximately three orders of magnitude higher than neat rPPS. Dynamic mechanical analysis showed improved viscoelastic response relative to neat rPPS, while tensile testing confirmed that the SMM-processed specimens retained practical mechanical integrity despite localized voids. These results demonstrate that SMM can effectively consolidate EM susceptible thermoplastic powder beds while preserving their segregated conductive networks. This may become a scalable route for producing multifunctional thermoplastic parts with low filler loadings, tunable anisotropy, and structured materials and parts. Overall, the findings suggest that EM field-based AM can help overcome key limitations of conventional thermoplastic processing by enabling scalable, energy-efficient fabrication of nanostructured composites and expanding AM to a broader range of resins, including high-performance thermoplastics with customized functional properties.

Powder bed fusion

Center for Space Transportation and Applied Research Fifth Annual Technical Symposium Proceedings

This Fifth Annual Technical Symposium, sponsored by the UT-Calspan Center for Space Transportation and Applied Research (CSTAR), is organized to provide an overview of the technical accomplishments of the Center's five Research and Technology focus areas during the past year. These areas include chemical propulsion, electric propulsion, commerical space transportation, computational methods, and laser materials processing. Papers in the area of artificial intelligence/expert systems are also presented.

Source record

Chapter 17 - Airframe Tests

This Section outlines the flight testing required to demonstrate that each of the systems installed in an aircraft is suitable for its operational role(s). It is primarily written from the perspective of a military Flight Test Engineer (FTE) but most of the contents are applicable to civil aircraft. Reflecting the introductory nature of this Volume, its scope is limited to systems normally found in all aircraft, e.g., fuel, hydraulic, electrical, etc., systems. The tests described below are usually made under the prevailing ambient conditions and, to assess behaviour under climatic extremes and in all weathers, further testing is conducted as described in Section 18. Tests of the propulsion system are covered separately in Section 23, but for systems associated with specific roles the reader should consult appropriate specialized sources.

J K Appleford

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.

Cort, Katherine

A Missed Thrust Framework for Low-Thrust Spiral Trajectories to the NRHO

A framework is developed by which end-to-end optimization of many-revolution low-thrust spiral trajectories can be completed in the presence of missed thrust events. This framework is applied to the Lunar Transit trajectory by which the initial capability of NASA’s Gateway lunar space station will be delivered to a Near Rectilinear Halo Orbit. This low-thrust mission consists of three subphases, each designed according to the specific objectives and dynamical regimes encountered as the mission progresses from a medium Earth insertion orbit to cislunar space. The presented framework accounts for the unique considerations demanded by each mission phase and incorporates appropriate capabilities into a novel mission analysis tool. This methodology enables large scale and reliable analyses of missed thrust events across the end-to-end Lunar Transit to verify the robustness of flight trajectories across the full range of considered launch dates.

missed thrust

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Queued Up: 2026 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2025 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with https://www.interconnection.fyi. Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 50 non-ISO balancing areas), which collectively represent ~98% of currently installed U.S. electric generating capacity.

24 POWER TRANSMISSION AND DISTRIBUTION

Mathematical Storage-Battery Models

Empirical formula represents performance of electrical storage batteries. Formula covers many battery types and includes numerous coefficients adjusted to fit peculiarities of each type. Battery and load parameters taken into account include power density in battery, discharge time, and electrolyte temperature. Applications include electric-vehicle "fuel" gages and powerline load leveling.

Chapman, C. P.

Associative polymers with controlled sticker placement: How reversible bond distribution and density govern polymer dynamics

Associative polymers with precisely arranged stickers offer opportunities to program material properties with molecular precision. Yet, it remains unclear how the placement and fraction of stickers dictate structure, dynamics, and macroscopic properties. By developing a model unentangled polymer system with hydrogen-bonding stickers, we show that randomly distributed stickers neither form clusters nor change flow properties, whereas stickers placed at chain ends drive nanocluster formation even at low concentrations. Adding more end stickers produces a rubbery plateau spanning eight decades in frequency with two distinct relaxation timescales, in contrast to the single plateau predicted by the classic sticky Rouse model. These results demonstrate that sticker distribution dictates whether associative polymers undergo nanocluster formation or microphase separation, while substantial alterations in dynamics and viscoelasticity require both sticker aggregation and thermomechanical stability of associated domains. Our findings resolve a longstanding debate on associative polymer dynamics and provide molecular design rules for programmable soft materials.

36 MATERIALS SCIENCE

Battery Charge Equalizer with Transformer Array

High-power batteries generally consist of a series connection of many cells or cell banks. In order to maintain high performance over battery life, it is desirable to keep the state of charge of all the cell banks equal. A method provides individual charging for battery cells in a large, high-voltage battery array with a minimum number of transformers while maintaining reasonable efficiency. This is designed to augment a simple highcurrent charger that supplies the main charge energy. The innovation will form part of a larger battery charge system. It consists of a transformer array connected to the battery array through rectification and filtering circuits. The transformer array is connected to a drive circuit and a timing and control circuit that allow individual battery cells or cell banks to be charged. The timing circuit and control circuit connect to a charge controller that uses battery instrumentation to determine which battery bank to charge. It is important to note that the innovation can charge an individual cell bank at the same time that the main battery charger is charging the high-voltage battery. The fact that the battery cell banks are at a non-zero voltage, and that they are all at similar voltages, can be used to allow charging of individual cell banks. A set of transformers can be connected with secondary windings in series to make weighted sums of the voltages on the primaries.

Davies, Francis

Theoretical design and performance of three-dimensional, pillared FeS 2 cathodes

Three-dimensional (3D) electrode design can provide improved capacities and rate capabilities over conventional two-dimensional electrodes by enhancing electrical and ionic transport. Here, expanding upon our previous modeling efforts for conversion chemistry lithium-ion batteries, we develop a pseudo-four-dimensional (P4D) approach that is subsequently used to investigate the design of a pillared FeS 2 electrode. The model considers transport in three dimensions with an additional “fourth” dimension corresponding to the solid-state lithium transport within the active material particles. Additionally, we allow for expansion of the active material during the conversion reaction to understand how internal stresses impact the electrochemical performance of the cell. By optimizing the model with respect to areal capacity, we are able to predict areal capacities up to 16.8 mAh/cm 2 for an areal current density of 1.78 mA/cm 2 and a 103% improvement for the three-dimensional electrodes over planar electrodes of equal volume. Despite the promising results, our simulations suggest that 3D design may be difficult for conversion cathode materials due to the large internal stresses that arise during conversion. Nevertheless, the model is robust and adaptable to other materials that may be more suitable for 3D electrodes due to a lesser change in volume during discharge.

Conversion cathode materials

Marshall Space Flight Center battery activity

The topics covered are presented in viewgraph form and include a flight program history and in-house activities. Some of the in-house activities addressed include secondary battery/cell testing and Hubble Space Telescope Test data updates involving the NiCd type 40 test - battery 1 and 2, the NiCd type 41 test battery, the general electric battery, the NiCd six-battery system, the six four-cell packs, fourteen-cell pack, three four-cell packs, the NiH2 six-battery system, and the flight spare battery. A general test data update is also presented for the twelve-cell pack, the four four-cell packs, the reconditioning test, and planned Ni-MH testing.

Lowery, Eric

Terrestrial Environment (Climatic) Criteria Guidelines for Use in Aerospace Vehicle Development, 1973 Revision

This document provides guidelines on probable climatic extremes and probabilities-of-occurrence of terrestrial environment data specifically applicable for NASA space vehicles and associated equipment development. The geographic areas encompassed are The Eastern Test Range (Cape Kennedy, Florida); Huntsville, Alabama; New Orleans, Louisiana; The Space and Missile Test Center (Vandenberg AFB California); Sacramento, California; Wallops Test Range (Wallops Island, Virginia); White Sands Missile Range, New Mexico; and intermediate transportation areas. In addition, sections have been included to provide information on the general distribution of natural environment extremes in the United States (excluding Alaska and Hawaii), cloud cover, and some worldwide climatic extremes. Although all these areas are covered, the major emphasis is given to the Kennedy Space Center launch area and Vandenburg Air Force Base due to importance in NASA's future large space vehicle programs. This document presents the latest available information on probable climatic extremes, and supersedes information presented in TM X-64589. The information in this document is recommended for employment in the development of space vehicles and associated equipment design and operational criteria, unless otherwise stated in contract work specifications.

cloud cover

Digital Twin Based Condition Monitoring of LCC-LCC Inductive Power Transfer Systems

Inductive power transfer (IPT) systems provide a flexible, hands-free charging opportunity to electric vehicles (EV). The resonant network components and the transmitter and receiver coils are often subjected to high voltages or currents. Component aging in the compensation network and coils of resonant IPT systems is detrimental to the reliability and power transfer efficiency of the IPT system. Monitoring the component health of such multi-element complex systems requires robust optimization algorithms. This paper discusses condition monitoring of a resonant IPT system for an EV charger using a digital twin model. A hybrid estimation algorithm based on genetic algorithms and adaptive particle swarm optimization is developed to estimate the parameters of the digital twin model. Simulation results are used to verify the monitoring capabilities of the developed algorithm under various operating conditions of the IPT system.

Weldehawaryat, Lidya Mussie [graduate research ass

Battery charge control with temperature compensated voltage limit

Battery charge control for orbiting spacecraft with mission durations from three to ten years, is a critical design feature that is discussed. Starting in 1974, the General Electric Space Systems Division designed, manufactured and tested battery systems for six different space programs. Three of these are geosynchronous missions, two are medium altitude missions and one is a near-earth mission. All six power subsystems contain nickel cadmium batteries which are charged using a temperature compensated voltage limit. This charging method was found to be successful in extending the life of nickel cadmium batteries in all three types of earth orbits. Test data and flight data are presented for each type of orbit.

Thierfelder, H. E.