At least 235 records · Page 13

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

SAXS Assistant: Automated SAXS analysis for structural discovery in biologics and polymeric nanoparticles

Small-angle x-ray scattering (SAXS) is a powerful technique for assessing macromolecular structure. High-throughput SAXS is limited by the time-consuming and, at times, subjective nature of SAXS data interpretation. Here, we present SAXS Assistant, a Python-based script that streamlines SAXS data analysis to extract features for machine learning (ML) and key structural parameters, including the Guinier radius of gyration (R g ), pair distance distribution function (PDDF)-derived R g , maximum particle dimension (D max ), and Kratky plots. The script builds upon BioXTAS RAW and validates reliability via Guinier/PDDF R g agreement, an important indicator of well-measured data sets. For assistance in D max estimation, a multilayer perceptron regressor was trained with 1940 data files from the Small Angle Scattering Biological Data Bank. The model achieved a test set performance R 2 = 0.90 and mean absolute error = 11.7 Å. Training exclusively with experimental data translates analyses from researchers, including experts in the field, to the ML model, which helps assess D max estimations from PDDF. Gaussian mixture model clustering was implemented to classify profiles into structural classes based on entries in the Small Angle Scattering Biological Data Bank. Users may therefore assess the similarity between experimental samples and known biomolecular shapes within the mapped repository entries. This probabilistic clustering aids in quantifying information from Kratky and generating shape-descriptive features. SAXS Assistant accelerates SAXS data analysis through enforced quality control, ML-ready outputs, and flags for low-confidence results. In addition to providing the ability to analyze large data sets at high throughput, this tool is versatile and may serve researchers in both biological and synthetic polymer research fields.

36 MATERIALS SCIENCE↗

High-Throughput Microstructural Characterization and Process Correlation Using Automated Electron Backscatter Diffraction

The need to optimize the processing conditions of additively manufactured (AM) metals and alloys has driven advances in throughput capabilities for material property measurements such as tensile strength or hardness. High-throughput (HT) characterization of AM metal microstructure has fallen significantly behind the pace of property measurements due to intrinsic bottlenecks associated with the artisan and labor-intensive preparation methods required to produce highly polished surfaces. This inequality in data throughput has led to a reliance on heuristics to connect process to structure or structure to properties for AM structural materials. In this study, we show a transformative approach to achieve laser powder bed fusion (LPBF) printing, HT preparation using dry electropolishing and HT electron backscatter diffraction (EBSD). This approach was used to construct a library of > 600 experimental EBSD sample sets spanning a diverse range of LPBF process conditions for AM Kovar. This vast library is far more expansive in parameter space than most state-of-the-art studies, yet it required only approximately 10 labor hours to acquire. Build geometries, surface preparation methods, and microscopy details, as well as the entire library of >600 EBSD data sets over the two sample design versions, have been shared with intent for the materials community to leverage the data and further advance the approach. Using this library, we investigated process–structure relationships and uncovered an unexpected, strong dependence of microstructure on location within the build, when varied, using otherwise identical laser parameters.

Characterization and Analytical Technique↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Enhanced Configurational Sampling Approaches to Alchemical Ligand Binding Free Energy Simulations: Current Status and Challenges

In this study, ligand binding free energy simulations (LB-FES) have been routine tasks in modern drug discovery campaign. A long-standing challenge for LB-FES is the difficulty in adequately sampling nontrivial environmental reorganizations in response to ligand binding. Therefore, various enhanced configurational sampling (ECS) approaches were devised to speed up fluctuations of relevant slow degrees of freedom (SDOF) and ensure simulation convergence. However, in contrast to the achievements in parametrization, software performance, and workflow automation, efficient ECS methodology suitable for high throughput screening remains in an early stage of development. Here, a review of ECS developments with LB-FES is presented, revisiting current approaches and underlining the major technical pitfalls and challenges. This Perspective focuses on alchemical LB-FES on account of their predominant role in high throughput drug screening as well as the established partnership with ECS. The critical aspects of designing ECS approaches, from both theoretical and applied perspectives, are described. This work is intended to provide a contemporary review of the scientific, technical, and practical issues associated with the accelerating convergence of alchemical LBFES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic-resolution lithography with an on-chip scanning tunneling microscope

In this work, atomic-resolution lithography with a Microelectromechanical-System (MEMS) based Scanning Tunneling Microscope (STM) is demonstrated for the first time. The microscope consists of a commercial UltraHigh-Vacuum (UHV) STM whose regular tip is replaced with a 1-Degree-of-Freedom (1-DOF) MEMS nanopositioner. This results in a hybrid STM system where XY-plane motions are provided by the piezotube of the original system and Z-axis motion by the MEMS with a higher bandwidth. Sharp tips made of Pt or W are added to the MEMS devices with postfabrication techniques. With this hybrid system, STM-based lithography is demonstrated on an H-passivated Si (100)-2×1 sample under UHV condition. Results prove the capability of the hybrid STM system for atomic-scale lithography. This capability, paired with the small footprint of the MEMS device, makes this approach a candidate for building a high-throughput parallel STM lithography platform by incorporating an array of 1-DOF MEMS devices that perform lithography in parallel.

Alipour, Afshin (ORCID:0000000263252067)↗

wastewater_virus

This repo contains software used to clean and assemble high-throughput sequencing data containing viruses. The input is raw illumina sequencing reads and the output is a database of high-quality viral genomes. The specific application is to wastewater viral concentrates but it is not restricted to that sample type. The software is composed of Nextflow workflows and a set of custom Python and bash scripts that call publicly available bioinformatics tools to accomplish obvious tasks in data analysis in a high performance computing environment. For detailed information, please see the repo's README file.

Kantor, Rose [Lawrence Livermore National Laborato↗

Optode performance data associated with: Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

This data package is associated with the publication “Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments”, submitted to PlosONE (Kaufman et al. 2023; 10.1101/2023.03.28.534656).We carried out many testing and calibration experiments on a system of small oxygen consumption batch reactors designed for use with water and sediment samples for environmental questions. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. Our primary focus was on practical considerations, such as temperature effects, lighting angle effects, sterilization, and other similar situations that a user may find useful. Most of the tests required comparing “base” calibration curves to “treatment” calibration curves to determine the extent to which the treatment impacted the reported measurements. This data package contains the performance and calibration data collected for that purpose.This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) diffusion test result files; (5) limit of detection test result files; (6) temperature impact files; (7) a main data file that contains test results for all other tests; and (8) an R script that uses Kolmogorov-Smirnov tests to determine whether treatment calibrations are significantly different from their respective base calibrations. All files are .csv, .txt, .Rmd, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

High-throughput ion irradiation of additively manufactured compositionally complex alloys

Several advanced nuclear reactor designs promise efficiency and safety improvements over the current reactor fleet but are limited by the current set of ASME code-qualified materials. Novel alloys including high-entropy alloys (HEAs), and more broadly compositionally complex alloys (CCAs), have shown promising irradiation-tolerance. However, the vast range of alloy compositions adds to an already time-consuming alloy development process. In this study, to accelerate the development of novel alloys for nuclear applications, a high-throughput (HTP) methodology has been employed. Additive manufacturing has been used to produce a compositional array of unary, binary, ternary, and quaternary alloys, including several CCAs, which span the Cr-Fe-Mn-Ni composition space. Additionally, the compositional array was homogenized at 1000°C for 24 hours and each sample was irradiated using 4-MeV Ni2+ ions at room temperature to a peak damage of 50 dpa, as estimated using SRIM, at the University of Wisconsin Ion Beam Laboratory. A custom XY stage was built to accommodate the large compositional array and half of each sample was masked during irradiation enabling both the irradiated and unirradiated properties of each alloy to be characterized side-by-side. Each alloy was characterized using X-ray fluorescence (XRF), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and nanoindentation. CALPHAD simulations spanning the entire Cr-Fe-Mn-Ni composition space at 1000°C were performed to compare predicted equilibrium phases with phases identified experimentally from the unirradiated regions of each alloy. Nanoindentation measurements indicate radiation-induced hardening ranging from ~1-1.5 GPa in each of Cr-Fe-Mn-Ni CCAs, which is relatively insensitive to modest changes in alloy composition and comparable to hardening observed in neutron irradiated Cr-Fe-Mn-Ni CCAs in the literature. Overall, a substantial time savings was realized by employing HTP synthesis, irradiation, and characterization in this study compared to conventional techniques, the implications of which are discussed.

36 MATERIALS SCIENCE↗

How Optical and Electrical Properties of ITO Coated Willow Glass Affect Photonic Curing Outcome for Upscaling Perovskite Solar Cell Manufacturing

Indium tin oxide (ITO) coated Willow® glass is an excellent substrate for roll-to-roll manufacturing of perovskite solar cells (PSCs) but can have large variability in its optical and electrical properties. Photonic curing uses intense light pulses instead of heat to process materials and can facilitate faster processing speeds in roll-to-roll manufacturing to upscale the production of PSCs. Since the entire film stack can absorb light and contributes to the photonic curing outcome, the substrate materials’ properties play an integral role. Furthermore, we present the effect of ITO transmittance on the photonic curing of nickel nitrate sol-gel precursors into nickel oxide and consequently the performance of PSCs fabricated with only photonic curing and no thermal annealing. Unexpectedly, ITO samples processed by photonic curing show improved optical and electrical properties.

14 SOLAR ENERGY↗

Analysis of an optical imaging system prototype for autonomously monitoring zooplankton in an aquaculture facility

Traditional approaches to biomonitoring in aquatic systems, such as sample collection, sorting, and identification, require significant time and effort, thereby limiting the spatiotemporal resolution of sample collection. Additionally, collection and preservation of samples for subsequent taxonomic identification and enumeration leads to mortality of organisms. Recent advances in technologies that utilize optical imaging and machine learning have provided new opportunities to expedite biomonitoring and lead to significant cost savings. These technologies can be advantageous to scientists or managers that conduct routine biomonitoring to inform operations, as in the case of aquaculture facilities. The Small Aquatic Organism optical imaging system (SAO) is a high-throughput optical imaging and classification prototype system that relies on computer vision and machine learning (Support Vector Machines, or SVMs) to autonomously identify and enumerate aquatic organisms. The SAO provides a more sustainable method of collecting large volumes of data and has the benefit of being used in situ. In this study, we tested the performance of the SAO in providing comparable results to manual zooplankton community monitoring in ten ponds at an aquaculture facility. We performed a side-by-side study comparing the sampling methods of plankton tow nets, where major zooplankton taxonomic classes were manually identified and enumerated, to sampling with the SAO. Vouchered samples were used to develop a training library for the SAO, where classes consisted of water boatman and zooplankton groups: cladocerans, copepod adults, copepod nauplii, and rotifers. SAO imagery was manually classified and compared with predicted results for validation. Accuracy for the SVM classifier of the SAO was 37.4 %. Convolutional Neural Networks (CNN) and Random Forest classifiers were also applied to SAO imagery and image features for comparison. The best CNN model and our Random Forest model had accuracies of 80.4 % and 46.6 % respectively. Challenges faced included the small size of copepod nauplii and rotifers and the limited resolution of the imaging camera, although there are tradeoffs between imaging resolution and the sample processing rate. Furthermore, our comparison shows that advancement in both optical imaging and ML are needed in order for the SAO prototype to yield comparable results to manual community monitoring in an aquaculture facility.

54 ENVIRONMENTAL SCIENCES↗

High-throughput synthesis and corrosion behavior of sputter-deposited nanocrystalline Al x (CoCrFeNi) 100-x combinatorial high-entropy alloys

High-entropy alloys (HEAs) are inherently complex and potentially span a vast composition space, making their research and discovery challenging. In the present study, high-throughput synthesis of an Al x (CoCrFeNi) 100-x combinatorial material library covering x = 4.5–40 atomic percent Al is achieved, using magnetron cosputtering. The effects of Al on the microstructure and corrosion behavior are investigated. With the increased amount of Al, crystal-structures of thin films transform from face-centered cubic (FCC) to body-centered cubic (BCC). Both the FCC and BCC thin films demonstrate a uniform elemental distribution. Corrosion characteristics of combinatorial samples immersed in the 3.5 wt% (wt%) NaCl solution are evaluated via electrochemical tests. Complementary X-ray photoelectron spectroscopy analysis reveals the compositional variation of passivated films formed on the sample surface after immersion. The results show that the Al x (CoCrFeNi) 100-x HEA thin films possess outstanding corrosion-resistant properties, but the resistance diminishes with the increasing Al content. The decreased corrosion resistance is revealed to be directly related to the constituents of passivated films.

36 MATERIALS SCIENCE↗

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

Optimal dimensionality selection for independent component analysis of transcriptomic data

Independent component analysis is an unsupervised machine learning algorithm that separates a set of mixed signals into a set of statistically independent source signals. Applied to high-quality gene expression datasets, independent component analysis effectively reveals both the source signals of the transcriptome as co-regulated gene sets, and the activity levels of the underlying regulators across diverse experimental conditions. Two major variables that affect the final gene sets are the diversity of the expression profiles contained in the underlying data, and the user-defined number of independent components, or dimensionality, to compute. Availability of high-quality transcriptomic datasets has grown exponentially as high-throughput technologies have advanced; however, optimal dimensionality selection remains an open question. We computed independent components across a range of dimensionalities for four gene expression datasets with varying dimensions (both in terms of number of genes and number of samples). We computed the correlation between independent components across different dimensionalities to understand how the overall structure evolves as the number of user-defined components increases. We then measured how well the resulting gene clusters reflected known regulatory mechanisms, and developed a set of metrics to assess the accuracy of the decomposition at a given dimension. We found that over-decomposition results in many independent components dominated by a single gene, whereas under-decomposition results in independent components that poorly capture the known regulatory structure. From these results, we developed a new method, called OptICA, for finding the optimal dimensionality that controls for both over- and under-decomposition. Specifically, OptICA selects the highest dimension that produces a low number of components that are dominated by a single gene. We show that OptICA outperforms two previously proposed methods for selecting the number of independent components across four transcriptomic databases of varying sizes. OptICA avoids both over-decomposition and under-decomposition of transcriptomic datasets resulting in the best representation of the organism’s underlying transcriptional regulatory network.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Degradable Biocomposite Thermoplastic Polyurethanes

In this project, the team developed tough and degradable biocomposite thermoplastic polyurethanes (TPUs) by incorporating bacterial spores into TPUs as a biofunctional living filler. The team screened various bacteria and selected the Bacillus subtilis ATCC 6633 strain as the final candidate, primarily due to its genomic availability, sporulation ability and TPU assimilation activity. The heat-shock tolerance of ATCC 6633 spores was further improved through evolutionary engineering via Adaptive Laboratory Evolution (ALE), demonstrating a 17.7-fold enhanced germination efficiency post heat-shock treatment compared to the wild-type strain (WT). The team fabricated biocomposite TPUs by incorporating lyophilized powder of heat-shock tolerized (HST) spores during the hot melt extrusion (HME) of TPU at 135 °C. The baseline TPU used in this project is a commercially available soft-grade TPU (BCF45) manufactured by BASF. Colony forming unit (CFU) assays quantified that WT and HST spores in the TPU matrix retained approximately 20% and 100% survivability, respectively, after HME. Tensile testing demonstrated that the spores behaved as a polymer-reinforcing filler, positively affecting the overall tensile properties of the biocomposite TPU. For example, biocomposite TPU with WT and HST spores (BC TPU WT and BC TPU HST , respectively) exhibited up to 25% and 37% improved toughness, respectively, compared to TPU without spores. BC TPU HST showed remarkably improved disintegration in autoclaved compost (92% mass loss in 5 months), which simulated a microbially poor environment for TPU degradation. When compared to TPU without spores (44% mass loss in 5 months) the acceleration of degradation is marked. Respirometry confirmed that 72% of BC TPU HST was biomineralized into CO2 within 6 months, indicating that spores in the biocomposite TPU were germinated by utilizing nutrients in the autoclaved compost, facilitating TPU degradation at the end of the material's life. The team demonstrated the scale-up of biocomposite TPU fabrication using continuous extrusion and injection molding techniques. Processing conditions optimized in a lab-scale microcompounder were successfully transferred to a continuous extruder with a 30-fold increased throughput. Biocomposite TPUs prepared using these industry-relevant processes showed comparable toughness improvements to samples prepared in the lab-scale extruder. Excitingly, following compounding in the pilot-extruder the composite material could be injection molded, while retaining high spore viability and similar toughness improvements. The team also found that spores in biocomposite TPU served as antioxidants, preventing toughness decay during the recycled extrusion of BC TPU HST . Long-term storage tests over one year showed that the addition of spores had no negative effect on the longevity of the TPU. Furthermore, the team demonstrated the fabrication of spore-bearing biocomposite polymers with other polyesters such as PBAT, PLA, and PCL. We obtained promising preliminary data that showed overall toughness improvements for all polymers with spore addition. Finally, life cycle assessment (LCA) and techno-economic analysis (TEA) were carried out, which indicated minimal additional cost of fabrication. Overall, a tough and degradable biocomposite thermoplastic was successfully developed through this project, with all tasks completed successfully, achieving >100% of the objectives.

36 MATERIALS SCIENCE↗

Exploring the First High-Entropy Thin Film Libraries: Composition Spread-Controlled Crystalline Structure

Thin films of two types of high-entropy oxides (HEOs) have been deposited on 76.2 mm Si wafers using combinatorial sputter deposition. In one type of the oxides, (MgZnMnCoNi)O x , all the metals have a stable divalent oxidation state and similar cationic radii. In the second type of oxides, (CrFeMnCoNi)O x , the metals are more diverse in the atomic radius and valence state, and have good solubility in their sub-binary and ternary oxide systems. Therefore, the resulting HEO thin films were characterized using several high-throughput analytical techniques. The microstructure, composition, and electrical conductivity obtained on defined grid maps were obtained for the first time across large compositional ranges. The crystalline structure of the films was observed as a function of the metallic elements in the composition spreads, that is, the Mn and Zn in (MgZnMnCoNi)O x and Mn and Ni in (CrFeMnCoNi)O x . The (MgZnMnCoNi)O x sample was observed to form two-phase structures, except single spinel structure was found in (MgZnMnCoNi)O x over a range of Mn > 12 at. % and Zn < 44 at. %, while (CrFeMnCoNi)O x was always observed to form two-phase structures. Composition-controlled crystalline structure is not only experimentally demonstrated but also supported by density function theory calculation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast (1‐5 sec) Lamination of Perovskite Solar Cells With Self‐Encapsulation Using Rapid Joule Heating

Perovskite solar cells (PSCs) are traditionally fabricated using sequential layer‐by‐layer deposition, in which each layer of the device is processed on top of the preceding layer. This constrains the processing techniques and selection of transport layer materials that can be used in the solar cell. To overcome these challenges, two half‐cells can be processed independently and then diffusion‐bonded through a lamination process. However, current lamination processes for perovskite solar cells suffer from relatively long process times, which can limit throughput when moving toward high‐volume manufacturing. In this study, a custom platform was designed for rapid‐joule heating of perovskite materials and devices. This enabled more than a 99% reduction in lamination time from 26 min to 1 s. Perovskite samples that were laminated in 1 s exhibited comparable values of percent bonded area, interfacial toughness, grain domain size, and X‐ray diffraction spectra to those laminated in greater than 10 min. As a proof‐of‐concept, 18.3% efficient devices were successfully laminated in 5 s. A transient heat transfer model was developed to describe the relationship between the perovskite temperature and the electrical power supplied to the heaters, establishing a baseline for predicting processing conditions in large‐scale manufacturing systems. Ultra‐fast lamination provides a pathway toward scalable roll‐to‐roll or sheet‐to‐sheet manufacturing of PSCs.

heat transfer↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.