Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Characterization of Crystal Properties and Defects in CdZnTe Radiation Detectors

CdZnTe-based detectors are highly valued because of their high spectral resolution, which is an essential feature for nuclear medical imaging. However, this resolution is compromised when there are substantial defects in the CdZnTe crystals. In this study, we present a learning-based approach to determine the spatially dependent bulk properties and defects in semiconductor detectors. This characterization allows us to mitigate and compensate for the undesired effects caused by crystal impurities. We tested our model with computer-generated noise-free input data, where it showed excellent accuracy, achieving an average RMSE of 0.43% between the predicted and the ground truth crystal properties. In addition, a sensitivity analysis was performed to determine the effect of noisy data on the accuracy of the model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Cryosectioning-enhanced super-resolution microscopy for single-protein imaging across cells and tissues

DNA-points accumulation for imaging in nanoscale topography (DNA-PAINT) enables nanoscale imaging with virtually unlimited multiplexing and molecular counting. Here, we address challenges, such as variable imaging performance and target accessibility, that can limit its broader applicability. Specifically, we enhance its capacity for robust single-protein imaging and molecular counting by optimizing the integration of total internal reflection fluorescence microscopy with physical sectioning, in particular, Tokuyasu cryosectioning. Our method, tomographic and kinetically enhanced DNA-PAINT (tkPAINT), achieves 3 nm localization precision across diverse samples, enhanced imager binding, and improved cellular integrity. tkPAINT can facilitate molecular counting with DNA-PAINT inside the nucleus, as demonstrated through its quantification of the in situ abundance of RNA Polymerase II in both HeLa cells as well as mouse tissues. Anticipating that tkPAINT could become a versatile tool for the exploration of biomolecular organization and interactions across cells and tissues, we also demonstrate its capacity to support multiplexing, multimodal targeting of proteins and nucleic acids, and three-dimensional (3D) imaging.

Science & Technology - Other Topics↗

Soft X-ray reflection ptychography

Scanning transmission X-ray microscopy and ptychography have become mature tools for high-resolution, element-specific imaging of nanoscale structures. However, transmission geometries impose stringent constraints on sample thickness and preparation, thereby limiting investigations of extended or bulk specimens, especially in the soft X-ray region. Here, we demonstrate reflection-geometry soft X-ray ptychography as a robust imaging mode. Instrumental feasibility and spatial resolution are established using a lithographically defined Siemens star and barcode test pattern on a multilayer substrate. We empirically demonstrate a full-pitch spatial resolution of ca. 45 nm from Fourier ring correlation analysis of the reconstructed object. The results highlight the potential of the reflection geometry for nondestructive X-ray studies of materials without the need for transmissive samples.

Guenzing, Damian [Lawrence Berkeley National Labor↗

Ultrafast nano-imaging and nano-spectroscopy

Ultrafast pump–probe nano-imaging combines scanning probe-based optical near-field microscopy with ultrafast spectroscopy to enable imaging with deep sub-wavelength spatial resolution, femtosecond temporal resolution and simultaneous spectral resolution. Ultrafast nano-imaging has gained increased attention for its ability to provide far-from-equilibrium excitation and excited-state contrast. With coherent and nonlinear probing, coupled electron, spin and lattice dynamics on elementary timescale and length scale can be resolved. Through nano-movies, ultrafast nano-imaging visualizes correlated quantum dynamics underlying the properties of solid-state materials, semiconductors, molecular electronic, photonic, photovoltaic and other functional materials. With nanometre spatial resolution, this method probes elementary dynamic processes across multiple length scales that are otherwise obscured in conventional ultrafast spectroscopy in which heterogeneities are spatially averaged. Furthermore, this Primer describes the theoretical background and experimental implementation of ultrafast nano-imaging; signal interpretation and modelling; representative examples and a perspective for the future development of the field.

Microscopy↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

Deep generative learning of magnetic frustration in artificial spin ice from magnetic force microscopy images

Increasingly large datasets of microscopic images with nanoscale resolution facilitate the development of machine learning methods to identify and analyze subtle physical phenomena embedded within the images. In this work, microscopic images of honeycomb lattice spin-ice samples serve as datasets from which we automate the calculation of net magnetic moments and directional orientations of spin-ice configurations. In the first stage of our workflow, machine learning models are trained to accurately predict magnetic moments and directions within spin-ice structures. Variational Autoencoders (VAEs), an emergent unsupervised deep learning technique, are employed to generate high-quality synthetic magnetic force microscopy (MFM) images and extract latent feature representations, thereby reducing experimental and segmentation errors. The second stage of proposed methodology enables precise identification and prediction of frustrated vertices and nanomagnetic segments, effectively correlating structural and functional aspects of microscopic images. This facilitates the design of optimized spin-ice configurations with controlled frustration patterns, enabling potential on-demand synthesis.

36 MATERIALS SCIENCE↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

Assessing methods in fusion and fitting for time series construction in remote sensing-based earth observations

This study evaluates the comparative performance of spatiotemporal fusion and time-series fitting methods for constructing high-spatiotemporal-resolution remote sensing time-series data. Due to in-class similarity of fusion methods and fitting methods, we employ the Fit-FC (Fitting, spatial Filtering, and residual Compensation) model as a representative fusion method and the linear harmonic fitting model as a representative fitting method. Both Fit-FC and the linear harmonic fitting are widely used for high-spatiotemporal-resolution time-series data construction, and we modify the original Fit-FC model to enable automatic time-series fusion. To ensure data representativeness, we use 3 years (2019–2021) of Harmonized Landsat and Sentinel-2 surface reflectance datasets and Terra MCD43A4 products. Eight experimental regions are selected worldwide to guarantee generalization of the comparative performance between fusion and fitting methods, covering diverse land-use types (cropland, developed land, forest, and grassland) and varying climatological conditions. Time-series of NDVI and surface reflectance are analyzed under both actual observations and simulated data-missing scenarios. The constructed time-series data reveals that (1) the modified Fit-FC and linear harmonic fitting model achieve excellent performance in constructing high-resolution time-series images; (2) the fusion method outperforms the fitting method in constructing time-series of NDVI and surface reflectance images in cropland-, forest-, and grassland-dominated regions; (3) both methods achieve comparable performance in developed-dominated regions; (4) the fusion method is more robust to missing data, and better captures abrupt phenological transitions under conditions of continuous missing data; (5) the fitting method is computationally more efficient, making it suitable for large-scale time-series image reconstruction. This study provides valuable insights for selecting optimal strategies to generate high-resolution time-series images across diverse application scenarios and lays a foundation for extensions to other vegetation indices or land surface variables.

54 ENVIRONMENTAL SCIENCES↗

Characterizing degraded visual environments with scanning lenses to improve contrast recovery

Atmospheric aerosols, such as fog and smoke, degrade optical signals via the scattering and absorption of light, making it difficult to recover information from the surrounding environment. Here, we present a technique that measures the angular distribution of light in scattering environments to help recover these degraded optical signals. This is done by passing a collimated beam through the aerosol environment and collecting the scattered and unscattered light with an f-theta scan lens. The lens transforms the angular distribution of the scattered light into the linear domain, mapping the collected light onto a detector. The measured angular scattering distribution is then used to estimate the point spread function of the environment at an arbitrary stand-off distance. This point spread function can be used to deconvolve images blurred by the aerosol environment in which the angular scattering distribution was initially measured. With this approach, we demonstrate improvements in the effective resolution of deblurred images up to 26% over a 120-cm stand-off distance. Experimentation was performed in the Sandia National Laboratories tabletop fog chamber, a platform that generates aerosol environments analogous to real-world fogs. We intend to leverage this technique in future work to develop a low-SWaP system for the in situ characterization of aerosol environments.

Aerosols↗

Three-dimensional structure of buried heterointerfaces revealed by multislice ptychography

Here, we report on the three-dimensional (3D) structure determination of a twisted hexagonal boron nitride (h-BN) heterointerface from a single-view dataset using multislice ptychography. We identify the buried heterointerface between two twisted h-BN flakes with a lateral resolution of 0.57 Å and a depth resolution of 2.5 nm. The latter represents a significant improvement (∼2.7 times) over the aperture-limited depth resolution of incoherent imaging modes, such as annular-dark-field scanning transmission electron microscopy. This improvement is attributed to the diffraction signal extending beyond the aperture edge, with the depth resolution set by the curvature of the Ewald sphere. Future advancements in this approach could enhance the depth resolution to the subnanometer level and enable the identification of individual dopants, defects, and color centers in twisted heterointerfaces and other materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗