Search NASA⌕ Search

SEARCH · Search NASA

Results for “Projection imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Adapting DESGW Single Epoch Image Differencing to the LSST Software Stack

Optical follow-up for gravitational wave events remains an important factor in potentially unlocking the secrets of dark matter in the universe. The Dark Energy Survey Gravitational Wave (DESGW) Group currently processes optical data from Dark Energy Camera (DECam) using a custom software pipeline derived from existing DES Supernovae Processing pipelines. While effective, is difficult to maintain and develop a custom workflow as new processing strategies are discovered, and researchers are diverted to newer projects in dark energy investigations. By building a modified image ingestion script and implementing the open-source Legacy Survey of Space and Time (LSST) Processing Pipeline for DESGW data, the lifetime and efficiency of the DESGW difference imaging program can be extended.

79 ASTRONOMY AND ASTROPHYSICS↗

Early Career Award: Single Molecule Fluorescence Imaging for a Background-Free Neutrinoless Double Beta Decay Search

This project aimed to develop a suite of novel technologies targeted at detecting individual barium ions produced in neutrinoless double beta decays of 136 Xe, as part of the NEXT program of gaseous xenon detectors. We realized novel molecules which could sense Ba 2+ ions in dry conditions; new microscopy techniques operable in dry noble gases, including the required operating conditions of xenon at 10 bar pressure; and new radiofrequency ion transport methods (developed both theoretically and experimentally) that can transport ions in dense xenon gas. Together, these developments represent a major advance toward a background-free neutrinoless double beta decay experiment based on single molecule fluorescence imaging of Ba 2+ daughter ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning enables nanoscale X-ray 3D imaging with limited data

Deep neural network can greatly improve tomography reconstruction with limited data. A recent effort of combining ptycho-tomography model with the 3D U-net demonstrated a significant reduction in both the number of projections and computation time, and showed its potential for integrated circuit imaging that requires high-resolution and fast measurement speed.

47 OTHER INSTRUMENTATION↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FGC 1287 and its enigmatic 250 kpc long HI tail in the outskirts of Abell 1367

ABSTRACT We present H i and radio continuum, narrow-band Hα imaging, IFU spectroscopy, and X-ray observations of the FGC 1287 triplet projected ∼1.8 Mpc west of the galaxy cluster Abell 1367. One triplet member, FGC 1287, displays an exceptionally long, 250 kpc H i tail and an unperturbed stellar disc which are the typical signatures of ram pressure stripping (RPS). To generate detectable RPS signatures the presence of an Intracluster medium ICM or intragroup medium IGM with sufficient density to produce RPS at a realistic velocity relative to the ICM or IGM is a prerequisite. However, XMM–Newton observations were not able to detect X-ray emission from the triplet, implying that if a hot ICM/IGM is present, its density, ne, is less than 2.6 × 10−5 cm−3. Higher resolution VLA H i data presented here show FGC 1287’s H i disc is truncated and significantly warped, whereas the H i tail is clumpy. TNG Hα imaging identified three star-forming clumps projected within 20 kpc of FGC 1287’s disc, with VIMOS–IFU data confirming two of these are counterparts to H i clumps in the tail. The triplet’s H i kinematics, together with Hα and radio continuum imaging suggests an interaction may have enhanced star formation in FGC 1287’s disc, but cannot readily account for the origin of the long H i tail. We consider several scenarios which might reconcile RPS with the non-detection of ICM or IGM X-ray emission but none of these unambiguously explains the origin of the long H i tail.

Scott, T. C. (ORCID:0000000237464859)↗

Deep learning enhanced super-resolution x-ray fluorescence microscopy by a dual-branch network

X-ray fluorescence (XRF) microscopy is a powerful technique for quantifying the distribution of elements in complex materials, which makes it a crucial imaging technique across a wide range of disciplines in physical and biological sciences, including chemistry, materials science, microbiology, and geosciences. However, as a scanning microscopy technique, the spatial resolution of XRF imaging is inherently constrained by the x-ray probe profile and scanning step size. Here we propose a dual-branch machine learning (ML) model, which can extract scale-variant features and bypass abundant low-frequency information separately, to enhance the spatial resolution of the XRF images by mitigating the effects of blurring from the probe profile. The model is trained by simulated natural images, and a two-stage training strategy is used to overcome the domain gap between the natural images and experimental data. The tomography reconstruction from enhanced XRF projections shows an improvement in resolution by a scale factor of four and reveals distinct internal features invisible in low-resolution XRF within a battery sample. This study offers a promising approach for obtaining high-resolution XRF imaging from its low-resolution version, paving the way for future investigations in a broader range of disciplines and materials.

36 MATERIALS SCIENCE↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle trajectory representation learning with masked point modeling

Liquid argon time projection chambers (LArTPCs) offer millimeter-scale 3D images of particle trajectories, enabling precision studies of neutrino oscillation, detection of supernova and solar neutrinos, searches for exotic dark matter, and proton decay. Current approaches utilize supervised machine learning models, requiring extensive simulations of particle physics and detector response that can introduce bias. Self-supervised learning (SSL), a machine learning approach that learns useful representations of unlabeled data from the data itself, has significantly advanced how large datasets are utilized for representation learning; however, its potential for applications to sensory data in high precision particle physics experiments remains largely unexplored. We introduce the Point-based liquid argon masked autoencoder (PoLAr-MAE), a self-supervised framework that learns physically meaningful representations directly from unlabeled LArTPC images. PoLAr-MAE achieves remarkable data efficiency for a point-level segmentation task, outperforming fully supervised methods in low data regimes. Linear classifiers on model outputs demonstrate robust performance across multiple downstream tasks. Our results position sensor-level SSL as a practical foundation model strategy for LArTPCs.

Young, Samuel [Stanford Univ., CA (United States)]↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗