Search NASA⌕ Search

SEARCH · Search NASA

Results for “transmission operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters: Preprint

This paper investigates operational techniques to achieve smooth microgrid (MG) transitions by dispatching the grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control mode during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worthy to explore how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. As expected, the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires the GFM inverter(s) to maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-following control↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

Scalable Stochastic Transmission Expansion: A Use Case for ExaSGD

The intermittent nature of renewable energy poses new challenges for power grids due to its variable and un- certain power output. These features of renewable generation are becoming more relevant to transmission planning as grids reach higher penetration levels of renewable energy. In this paper we present an approach for transmission planning based on scalable computational approaches which enable the explicit consideration of operational uncertainties in the planning process. Using three-stage stochastic programming and the progressive hedging algorithm, we compute transmission expansion decisions on a modified RTS-GMLC test system. We augment the grid with large amounts of wind generation and consider many operational scenarios subject to wind uncertainty. This is an example of a possible use of the ExaSGD security constrained AC optimal power flow solver.

Exascale Computing Project↗

Deep Reinforcement Learning-Based Control of Energy Storage for Interarea Oscillation Damping

With the increasing electricity consumption and lack of transmission investment, today's power systems are operated much closer to their limits, raising concerns of inter-area oscillations that deteriorate the system stability. Here, this article presents a novel energy storage placement and control approach for enhanced damping of interarea oscillations. Combining the residual analysis and dominant mode analysis, we are able to identify the advantageous locations for placing energy storage that achieve improved damping performance. To overcome the challenges, such as fixed control parameters and insufficient damping, we propose to use a deep reinforcement learning-based approach for energy storage control. A state-of-the-art guided surrogate-gradient-based evolutionary strategy is used to train a learning agent in a robust, efficient, and reproducible manner. Parallel computing is also adopted to speed up the training process. The proposed strategy has been tested on both medium and large-scale systems. The proposed methods have demonstrated their effectiveness in mitigating various interarea oscillations within a timeframe of 20 s, thereby averting system collapse and enhancing power grid stability effectively.

25 ENERGY STORAGE↗

Spatially resolved structural order in low-temperature liquid electrolyte

Determining the degree and the spatial extent of structural order in liquids is a grand challenge. Here, we are able to resolve the structural order in a model organic electrolyte of 1 M lithium hexafluorophosphate (LiP 6 ) dissolved in 1:1 (v/v) ethylene carbonate:diethylcarbonate by developing an integrated method of liquid-phase transmission electron microscopy (TEM), cryo-TEM operated at -30°C, four-dimensional scanning TEM, and data analysis based on deep learning. This study reveals the presence of short-range order (SRO) in the high–salt concentration domains of the liquid electrolyte from liquid phase separation at the low temperature. Molecular dynamics simulations suggest the SRO originates from the Li + - (PF 6 - ) n (n > 2) local structural order induced by high LiP 6 salt concentration.

42 ENGINEERING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Analog optical signal transmission for HEP experiments

A critical element in all high-energy physics experiments is the signal transmission from the active elements to the data acquisition system. It is especially challenging in large volume detectors based on noble liquids that are extensively being used for dark matter and neutrino detection.The topic of this contribution is the optical signal transmission of the signals acquired with silicon photomultipliers, which is able to satisfy many stringent experimental requirements. It is RF-noise immune and operates in cryogenic liquids and in high-electric fields.This transmission system is based on commercially available electronics components and customized Fabry-Perot laser diodes.I will talk about encountered challenges, breakthrough, and advances from the original concept of this system up to final validation tests, demonstrating progressive developments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states.For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

What Is Power System Curtailment?

Curtailment is the intentional reduction of instantaneous power from non- dispatchable variable renewable energy (VRE) resources like wind and solar photovoltaics relative to what would naturally be available from the wind and the sun. This curtailed energy is the difference between the total available energy and actual production. This fact sheet provides a summary of curtailment in power systems and presents selected insights into specific ways in which curtailment is implemented by a selection of System Operators.

curtailment↗

Chapter 9: Impact of Variable Renewable Energy Sources on Bulk Power System Planning and Operations

Wind and solar photovoltaics (PV) have experienced remarkable growth in recent years, with many consequent benefits within and outside of power systems. At the same time, wind and solar PV have unique characteristics relative to the historically dominant dispatchable technologies like coal, gas, and nuclear power plants that have required and will continue to require changes in power system planning and operations. This chapter discusses planning and operational challenges of integrating wind and solar PV into bulk power systems. We first present the key characteristics of wind and solar PV that differentiate it from conventional technologies, such as variable and uncertain electricity generation, asynchronous interconnection to the power system, and near-zero marginal costs. We then link these characteristics to power system planning and operational challenges at low through high wind and solar penetrations. Finally, we discuss near- and long-term solutions to those challenges, such as diversifying the generation mix and wind and solar fleets, improving system flexibility, diversifying ancillary service products, and integrating generation and transmission planning.

bulk power system↗

Energy Scheduling-based Operating Envelopes including a Distribution System Branch Screening Algorithm

This paper presents an energy scheduling-based formulation for computing operating envelopes including a distribution branch screening algorithm, termed DBS-ES. The contribution of the paper is two-fold: firstly, it presents an innovative methodology for calculating operating envelopes using energy scheduling (baseline), and secondly, it enhances this methodology by incorporating a custom distribution branch screening algorithm (DBS-ES). The custom algorithm leverages power system knowledge to reduce both model build time and total processing time while maintaining the same scheduling results as the baseline. The effectiveness of the proposed approach is demonstrated through experiments on the IEEE13, IEEE123, and EPRI Secondary test feeders. Results highlight a 24.5% decrease in model build time and an 8.17% decrease in total processing time when using DBS-ES compared to the baseline, specifically for the IEEE123 test feeder. Additionally, the paper briefly discusses the influence of utility-controlled storage on computing operating envelopes, noting a general incre

24 POWER TRANSMISSION AND DISTRIBUTION↗