Search NASA⌕ Search

SEARCH · Search NASA

Results for “solvent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Quantitation of buried contamination by use of solvents

Spore recovery form cured silicone potting compounds using amine solvents to degrade the cured polymers was investigated. A complete list of solvents and a description of the effect of each on two different silicone polymers is provided.

Pappas, S. P.↗

Coal mining with a liquid solvent

Study suggests carbonated water can dissolve or suspend coal and carry it to surface. Mixture of carbon dioxide and water may be coal solvent that will make unmanned mining reality. When used with proposed process monitoring coal solubility with conventional strain gage, solvent is basis for rapid cost effective extraction of coal from underground seams.

Lawson, D. D.↗

Development of a solvent processed insensitive propellant

Two types of low vulnerability propellants are studied which are distinguished by whether the binder is a rubber, such as polyurethane or CTBN, or a plasticizable polymer such as ethyl cellulose or cellulose acetate. The former propellants are made by a partial cure extrusion process while the latter are made by the conventional solvent process. Emphasis is given to a cellulose binder (plasticizer) RDX composition. The type of binder used, the particle size of the RDX and the presence of small quantities of nitrocellulose in the solvent processed compositions have important influences on the mechanical and combustion characteristics of the propellant. The low temperature combustion is of particular concern because of potential breakup of the grains that can lead to instability.

Trask, R.↗

Improved Supercritical-Solvent Extraction of Coal

Raw coal upgraded by supercritical-solvent extraction system that uses two materials instead of one. System achieved extraction yields of 20 to 49 weight percent. Single-solvent yields are about 25 weight percent. Experimental results show extraction yields may be timedependent. Observed decreases in weight of coal agreed well with increases in ash content of residue.

Compton, L.↗

A Solvent-Resistant, Thermoplastic Poly(imidesulfone)

Process for preparing thermoplastic poly(imidesulfone) results in material having excellent thermoplastic properties generally associated with polysulfones and excellent solvent resistance generally associated with polyimides. New thermoplastic, solvent-resistant polymer is used as molding resin, as adhesive, and as matrix resin for fiber reinforced composites.

St. Clair, T. L.↗

Solvent-Resistant Polysulfones

Polysulfones terminated with trimethylsilylethynyl, ethynyl, and phenylethynyl groups increased solvent resistance. Upon application of heat, with or without catalyst, end groups react to provide cross linking and chain extension. Result: temperature of polymer increased, more importantly, solvent resistance greatly improved. Solutions used conveniently for preparation of films, coatings, membranes, prepreg, and adhesive tapes.

Hergenrother, P. M.↗

Supercritical-Multiple-Solvent Extraction From Coal

Large and small molecules dissolve different constituents. Experimental apparatus used to test supercritical extraction of hydrogen rich compounds from coal in various organic solvents. In decreasing order of importance, relevant process parameters were found to be temperature, solvent type, pressure, and residence time.

Corcoran, W.↗

Cracks in Glass Polymers Induced by Solvent Absorption

Combination of soluble particles and absorbed solvents cause polymer cracking. New failure mechanism in glassy polymers identified. Cracking caused by presence of particles insoluble in polymer matrix but soluble in solvent. Experiments performed and equations describe cracking phenomenon set forth in concise report.

Fedors, R. F.↗

Supercritical multicomponent solvent coal extraction

The yield of organic extract from the supercritical extraction of coal with larger diameter organic solvents such as toluene is increased by use of a minor amount of from 0.1 to 10% by weight of a second solvent such as methanol having a molecular diameter significantly smaller than the average pore diameter of the coal.

Corcoran, W. H.↗

Supercritical solvent coal extraction

Yields of soluble organic extract are increased up to about 50% by the supercritical extraction of particulate coal at a temperature below the polymerization temperature for coal extract fragments (450 C.) and a pressure from 500 psig to 5,000 psig by the conjoint use of a solvent mixture containing a low volatility, high critical temperature coal dissolution catalyst such as phenanthrene and a high volatility, low critical temperature solvent such as toluene.

Compton, L. E.↗

Evaluation of mixed solvent electrolytes for ambient temperature secondary lithium cells

The ethylene carbonate/2-methyltetrahydrofuran (EC/2-MeTHF) mixed-solvent electrolyte has been experimentally found to possess many desirable electrolyte characteristics for ambient-temperature secondary Li-TiS2 cell applications. As many as 300 cycles have been demonstrated, and a cycling efficiency figure-of-merit of 38.5 percent, for 10-percent EC/90-percent MeTHF mixed-solvent electrolyte in experimental Li-TiS2 cells. The improved performance of this electrolyte is attributable to the formation of a beneficial passivating film on the Li electrode by interaction with the EC.

Shen, D. H.↗

Structure of the polymer-solvent interface

The first measurements of ellipticities from the liquid-liquid interface between polymer and solvent mixtures near their consolute points are reported. When scaled according to theory the ellipticities of high molecular weight polystyrene + solvent mixtures are consistent with those from simple, low molecular weight mixtures. The universal value of the scaled ellipticity is approximately 20 percent lower than that predicted by present theories.

Miles, Danny G., Jr.↗

Control of solvent evaporation in hen egg white lysozyme crystallization

An investigation of the role of solvent evaporation in tetragonal lysozyme crystallization was preformed with a device that employs N2(g) to control the evaporation of solvent from a micro-volume crystallization hanging drop. The number of crystals was found to vary with the rate at which the final supersaturation level was achieved. It was found that the more rapid the approach to supersaturation the larger the number of crystals. Accordingly, the crystals reached a smaller terminal size. Elongation of the (110) face parallel to the four-fold axis was observed with the slower evaporation rates.

Wilson, L. J.↗

Replacing Chlorinated-Solvent-Based Cleaners And Adhesives

Brief report describes tests conducted to assess feasibility of using selected chemicals as replacements for selected cleaners, primers, and adhesives containing chlorinated solvents. Cleaners, primers, and adhesives in question used in bonding insulating material in steel cases of solid-fuel rocket motors. Necessary to phase out use of chlorinated solvents because of concerns over toxicity and adverse effects on ozone layer in upper atmosphere.

Heaton, Harley↗

Evaluation of AK-225(R), Vertrel(R) MCA and HFE A 7100 as Alternative Solvents for Precision Cleaning and Verification Technology

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC) Materials Science Division conducted a study to evaluate alternative solvents for CFC-113 in precision cleaning and verification on typical samples that are used in the KSC environment. The effects of AK-225(R), Vertrel(R), MCA, and HFE A 7100 on selected metal and polymer materials were studied over 1, 7 and 30 day test times. This report addresses a study on the compatibility aspects of replacement solvents for materials in aerospace applications.

Orlando Melendez↗

The Influence of a Rotating Magnetic Field on Solidification from a Traveling Solvent Zone

Application of a high frequency rotating magnetic field (50-400Hz) (RMF) with a strength of the order of 1 mT can be used to influence the fluid flow in an electrically conductive melt. The advantage of the RMF during the traveling solvent zone method for growth of semiconductor materials will be discussed. Preliminary modeling results for cadmium telluride growth from a tellurium solvent zone will be discussed.

Gillies, Donald C.↗

Electrostatic Hazard Considerations for ODC Solvent Replacement Selection Testing

ODC solvents are used to clean many critical substrates during solid rocket motor production operations. Electrostatic charge generation incidental to these cleaning operations can pose a major safety issue. Therefore, while determining the acceptability of various ODC replacement cleaners, one aspect of the selection criteria included determining the extent of electric charge generation during a typical solvent cleaning operation. A total of six candidate replacement cleaners, sixteen critical substrates, and two types of cleaning swatch materials were studied in simulated cleaning operations. Charge generation and accumulation effects were investigated by measuring the peak voltage and brush discharging effects associated with each cleaning process combination. In some cases, charge generation was found to be very severe. Using the conductivity information for each cleaner, the peak voltage data could in some cases, be qualitatively predicted. Test results indicated that severe charging effects could result in brush discharges that could potentially result in flash fire hazards when occurring in close proximity to flammable vapor/air mixtures. Process controls to effectively mitigate these hazards are discussed.

Fairbourn, Brad↗

Evaluation of Solvent Alternatives for Cleaning of Oxygen Systems

The NASA White Sands Test Facility (WSTF) in a joint program with the Naval Sea Systems Command has evaluated a number of solvents as alternatives to the use of chlorofluorocarbons currently utilized for cleaning of oxygen systems. Particular attention has been given to the cleaning of gauges and instrumentation used in oxygen service, since there have been no identified aqueous alternatives. The requirements identified as selection criteria, include toxicity, physical properties consistent with application, flammability, oxygen compatibility, and cleaning ability. This paper provides a summary of results and recommendations for solvents evaluated to date.

Beeson, Harold↗