Deciphering the Evolution of Current Distribution in Hybrid Silver Vanadium Oxide / Carbon Monofluoride Cathodes within Lithium Primary Batteries

For batteries to function effectively all active material must be accessible requiring both electron and ion transport to each particle. A common approach to generating the needed conductive network is the addition of carbon to create a composite electrode. An alternative approach is the electrochemically induced formation of conductive reaction products where the electrochemically generated materials are in intimate contact with the active material contributing to effective connection of each active particle. Furthermore, this study probes silver vanadium oxide (Ag 2 V 4 O 11 , SVO), carbon monofluoride (CF x ), and hybrid SVO/CF x electrodes in lithium batteries. Ex situ XRD identifies Ag 0 as a reduction product from SVO and LiF from CF x that can be followed as a function of depth-of-discharge (DOD). Spatially-resolved operando energy dispersive x-ray diffraction reveals that the presence of SVO alleviates reaction heterogeneity in the electrodes which are electron transfer limited in the absence of sufficient Ag 0 . Synchrotron X-ray tomography on discharged cathodes reveals the distribution of silver particles where the particles are more closely spaced near the current collector indicating multiple nucleation sites for their formation. Finally, operando isothermal microcalorimetry is used to determine the heat dissipation of the parent and hybrid battery types. Using material enthalpy potentials, we determine the current distribution between the two active materials for the discharging hybrid cathode adding further insight to the diffraction analysis. Taken together, these results provide a comprehensive understanding of hybrid SVO/CF x cathodes and give guidance on optimal compositions that balance power and energy density considerations.

36 MATERIALS SCIENCE↗

Direct structural retrieval from gas-phase ultrafast diffraction data using a genetic algorithm

Ultrafast scattering techniques such as ultrafast electron diffraction and ultrafast x-ray diffraction have been utilized to elucidate the structural dynamics, reaction intermediates, and final products in molecular reactions following photoexcitation. The time-dependent structures are typically not directly retrieved from the experimental data, but they rely on comparison with calculations. The genetic algorithm (GA), a global optimization strategy, can be used to retrieve the molecular structures directly from diffraction patterns without any theoretical input. However, the robustness of the GA with respect to real experimental conditions such as a limited momentum transfer range, noise, and artifacts has not been studied in detail. In this work, we characterize the performance of the GA with simulated data that mimic realistic experimental conditions. We have developed and implemented a variant of the GA specific to diffraction measurements which performs better in the presence of imperfect data compared to the standard implementation of the GA. We demonstrate this method with both synthetic data and experimental ultrafast electron diffraction data on the UV-induced photodissociation of trifluoroiodomethane (C⁢F 3⁡ I) molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Second Target Station (STS) Project: PIONEER Technical Report

PIONEER is a time-of-flight single-crystal neutron diffractometer at the Second Target Station (STS), aiming at providing the world-leading capability to measure tiny crystals (~0.001 mm 3 , i.e., X-ray diffraction size), ultra-thin epitaxial films (~10 nm thicknesses), and weak structural transitions and complex magnetism. The instrument will take advantage of STS source characteristics and utilize advancements in neutron optics to largely reduce the sample-volume requirement for single-crystal neutron diffraction. PIONEER will have a high-flux mode with multiple beam size options to improve the signal-to-background ratio in various sample environments. It will also provide a high Q-resolution mode by limiting beam divergence to study periodically modulated structures with characteristic lengths no less than 100 Å. Furthermore, it supports half-polarized neutron diffraction for investigating complex magnetism and local susceptibility. This report first overviews the proposed science case and the derived requirement. And then, the chosen technical solutions and expected performance will be described.

36 MATERIALS SCIENCE↗

Vortex motion induced losses in tantalum resonators

Tantalum (Ta)-based superconducting circuits have been demonstrated to enable ultrahigh qubit quality factors (𝑄), motivating a careful study of the microscopic origin of the remaining losses that limit their performance. We have recently shown that the losses in Ta-based resonators are dominated by two-level systems at low microwave powers and millikelvin temperatures. We also observe that some devices exhibit loss that is exponentially activated at a lower temperature inconsistent with the superconducting critical temperature (T 𝑐 ) of the constituent film. Specifically, dc resistivity measurements show a T 𝑐 of over 4 K, while microwave measurements of resonators fabricated from these films show losses that increase exponentially with temperature with an activation energy as low as 0.3 K. Here, in this study, we present a comparative study of the structural and thermodynamic properties of Ta-based resonators and identify vortex motion-induced loss as the source of thermally activated microwave loss. Through careful magnetoresistance and x-ray diffraction measurements, we observe that the increased loss occurs for films that are in the clean limit, where the superconducting coherence length (𝜉) is shorter than the mean free path (𝑙). Vortex motion-induced losses are suppressed for films in the dirty limit, which show evidence of structural defects that can pin vortices. We verify this hypothesis by explicitly pinning vortices via patterning, and we find that we can suppress the loss by microfabrication.

36 MATERIALS SCIENCE↗

MHz free electron laser x-ray diffraction and modeling of pulsed laser heated diamond anvil cell

A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. In this report we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO 2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

Rapid sensing of hidden objects and defects using a single-pixel diffractive terahertz sensor

Abstract Terahertz waves offer advantages for nondestructive detection of hidden objects/defects in materials, as they can penetrate most optically-opaque materials. However, existing terahertz inspection systems face throughput and accuracy restrictions due to their limited imaging speed and resolution. Furthermore, machine-vision-based systems using large-pixel-count imaging encounter bottlenecks due to their data storage, transmission and processing requirements. Here, we report a diffractive sensor that rapidly detects hidden defects/objects within a 3D sample using a single-pixel terahertz detector, eliminating sample scanning or image formation/processing. Leveraging deep-learning-optimized diffractive layers, this diffractive sensor can all-optically probe the 3D structural information of samples by outputting a spectrum, directly indicating the presence/absence of hidden structures or defects. We experimentally validated this framework using a single-pixel terahertz time-domain spectroscopy set-up and 3D-printed diffractive layers, successfully detecting unknown hidden defects inside silicon samples. This technique is valuable for applications including security screening, biomedical sensing and industrial quality control.

Li, Jingxi (ORCID:0000000165958680)↗

Oxide-nitride heteroepitaxy for low-loss dielectrics in superconducting quantum circuits

Superconducting qubits show great promise for the realization of fault-tolerant quantum computing, but lossy, amorphous dielectrics limit current technology. Identifying highly crystalline and stoichiometric dielectrics with intrinsically low microwave loss is therefore a central materials challenge, yet experimentally validated platforms remain scarce. In this work, we integrate a crystalline dielectric into a heteroepitaxial TiN/$γ$-Al$_2$O$_3$/TiN trilayer grown via pulsed laser deposition. Correlative high-resolution imaging, diffraction, and spectroscopy measurements confirm the single-crystal quality and chemical integrity of all layers, with minimal defects and limited anion interdiffusion across the oxide-nitride interfaces. Using microwave lumped-element resonators with parallel-plate capacitors, we report the first direct measurement of the dielectric loss of epitaxial $γ$-Al$_2$O$_3$, for which we find a low intrinsic two-level system loss, $δ_{\text{TLS}}^0 = (2.8 \pm 0.1) \times 10^{-5}$. These results establish heteroepitaxial oxides on transition metal nitrides as an attractive materials platform for superconducting quantum circuits, particularly for integration into compact device architectures such as merged-element transmons and microwave kinetic inductance detectors.

Garcia-Wetten, David A. [Northwestern U.]↗

Nonlinear reversal of photoexcitation on the attosecond time scale improves ultrafast X-ray diffraction images

The complex refractive index of a material governs its light-matter interactions, with intense light fields enabling tailored nonlinear optical responses. In the X-ray regime, rapid photoionization limits the potential of nonlinear techniques by inducing irreversible electronic damage. Here we demonstrate that intense, sub-femtosecond X-ray pulses, shorter than typical Auger decay times, can partially reverse photoexcitation via stimulated emission near atomic resonances. By analyzing thousands of coherent diffraction patterns and ion spectra from neon nanoparticles exposed to sub-fs and 15-fs pulses, we observe enhanced X-ray diffraction alongside reduced energy absorption for sub-fs pulses. Theoretical modeling attributes this to dynamics akin to Rabi flopping that prolong the lifetime of resonant states and suppress electronic bleaching. These findings suggest that ultrashort, intense X-ray pulses enable active control of X-ray refractive index and damage pathways, opening avenues for improved high-resolution imaging and nonlinear spectroscopy in complex nanoscale systems.

Ulmer, Anatoli [Universität Hamburg (Germany)] (OR↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Microstructurally informed synchrotron x-ray analysis revealing helium defect transitions in ultrafine grained tungsten

The formation of insoluble gaseous defects in materials due to nuclear transmutation or ion implantation involves the diffusion of impurity atoms to form atomic defect clusters that coalesce into bubbles or cavities and ultimately degrade the material properties. Transmission electron microscopy (TEM) is limited in its ability to resolve sub-nanometer gas clusters whereas X-ray diffraction (XRD) provides information pertaining to local atomic changes. Here, in this study, helium (He) implanted ultrafine grained tungsten is explored through a multimodal defect characterization campaign combining TEM-informed Small Angle X-ray Scattering (SAXS) analysis, XRD lattice parameter measurements, and nanoscale He cluster quantification from a region of reciprocal space accessible via Wide Angle X-ray Scattering (WAXS). Moderate elevated temperature implantations are shown to produce high concentrations of sub-nanoscale He clusters and small, homogeneously distributed cavities, which collectively are linked to lattice expansion and further substantiated through complementary atomistic simulations. Increased implantation temperatures encourage the diffusion of these defects to the grain boundaries (GBs), leading to lattice relaxation and the growth of large GB cavities manifesting as bimodal size distributions in the SAXS analysis. Overall, our results demonstrate the utility of multimodal synchrotron X-ray analysis in bridging the gap between microscale He cavity quantification and atomic-scale defect analysis.

36 MATERIALS SCIENCE↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of tilt on circular zone plate performance

Fresnel zone plates are frequently used as focusing and imaging optics in x-ray microscopy, as they provide the ease of use of normal incidence optics. We consider here the effects of tilt misalignment on their optical performance, both in the thin optics limit and in the case of zone plates that are sufficiently thick so that volume diffraction effects come into play. Using multislice propagation, we show that simple analytical models describe the tilt sensitivity of thin zone plates and the thickness at which volume diffraction must be considered, and examine numerically the performance of example zone plates for soft x-ray focusing at 0.5 keV and hard x-ray focusing at 10 keV.

47 OTHER INSTRUMENTATION↗

Massively parallel and universal approximation of nonlinear functions using diffractive processors

Nonlinear computation is essential for a wide range of information processing tasks, yet implementing nonlinear functions using optical systems remains a challenge due to the weak and power-intensive nature of optical nonlinearities. Overcoming this limitation without relying on nonlinear optical materials could unlock unprecedented opportunities for ultrafast and parallel optical computing systems. Here, we demonstrate that large-scale nonlinear computation can be performed using linear optics through optimized diffractive processors composed of passive phase-only surfaces. In this framework, the input variables of nonlinear functions are encoded into the phase of an optical wavefront—e.g., via a spatial light modulator (SLM)—and transformed by an optimized diffractive structure with spatially varying point-spread functions to yield output intensities that approximate a large set of unique nonlinear functions–all in parallel. We provide proof establishing that this architecture serves as a universal function approximator for an arbitrary set of bandlimited nonlinear functions, also covering wavelength-multiplexed nonlinear functions as well as multi-variate and complex-valued functions that are all-optically cascadable. Our analysis also indicates the successful approximation of typical nonlinear activation functions commonly used in neural networks, including the sigmoid, tanh, ReLU (rectified linear unit), and softplus. We numerically demonstrate the parallel computation of one million distinct nonlinear functions, accurately executed at wavelength-scale spatial density at the output of a diffractive optical processor. Furthermore, we experimentally validated this framework using in situ optical learning and approximated 35 unique nonlinear functions in a single shot using a compact setup consisting of an SLM and an image sensor. These results establish diffractive optical processors as a scalable platform for massively parallel universal nonlinear function approximation, paving the way for new capabilities in analog optical computing based on linear materials.

Rahman, Md Sadman Sakib [University of California,↗

Experimental thermal equation of state of B 2–KCl

The alkali halides are often used as optically-transparent pressure-transmitting media and thermal insulators in laser-heated diamond anvil cell experiments. High P-T equations of state for these materials would allow them to be used simultaneously as sensitive in situ pressure markers, making sample preparation and data analysis simpler. KCl is especially useful for this application because its high melting point, crystallographic simplicity, and low electron density are ideal for use in high-temperature X-ray diffraction experiments. However, the high-temperature static equation of state data for this material is limited in pressure to 8 GPa. As experiments routinely exceed 100 GPa in pressure and thousands of Kelvin, it is necessary for the equation of state of KCl to be determined experimentally at these conditions if it is to be used as an equation of state calibrant in the future. This work combines new high-pressure, high-temperature data of the B2 phase of KCl (up to 167 GPa and 2400 K) with the previously published room-temperature data of Dewaele et al. (2012) to produce a Mie-Gruneisen-Debye thermal equation of state for this material. The room temperature equation of state parameters are similar to those reported previously: V 0 = 32.0(3) cm 3 /mole, K 0 = 24(1) GPa and $K$$^{'}_{0}$ = 4.56(5). The thermal parameters, 0 and q, are 2.9(4) and 1.0(1), respectively. While a q of 1 is expected, the 0 is higher than expected from previous calculations, lower pressure experimental data, and the available shockwave data. Here, previously-reported equations of state underestimate the pressure of KCl at high temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LaueMatching: an approach for rapid and robust indexing of Laue diffraction patterns

Traditional Laue diffraction pattern indexing often struggles with noisy data, weak signals, peak overlap and missing reflections, particularly from complex or deformed microstructures. Here, we introduce LaueMatching, a high-throughput indexing algorithm designed to overcome these limitations. LaueMatching utilizes a fundamentally different approach based on direct pattern correlation: experimentally pre-processed images are compared against a comprehensive pre-computed library of simulated diffraction patterns corresponding to a dense grid of possible orientations. This approach bypasses the need for explicit peak identification and fitting, steps that are often a failure point for traditional methods. The algorithm rapidly and robustly indexes multiple crystallographic orientations and crystal systems simultaneously, even from challenging patterns. LaueMatching's effectiveness and accuracy have been rigorously tested and validated on diverse experimental (Ni, Al, EuAl 2 O 4 ) and simulated diffraction patterns, demonstrating high-fidelity orientation refinement. Code to implement this approach on both CPU and GPU resources can be downloaded from https://github.com/AdvancedPhotonSource/LaueMatching.

36 MATERIALS SCIENCE↗

Mapping valence electron distributions with multipole density formalism using 4D-STEM

Recent advancement in aberration correction and detector technology opened a door to various applications using 4D-STEM, which yields a diffraction pattern for each scanning position within a crystal unit-cell in scanning transmission electron microscopy (STEM) and generates incredible amounts of data in momentum space. Currently 4D-STEM analysis relies on the center-of-mass of the diffraction patterns in electric field and charge density mapping. It only derives the total projected charge density and is limited to phase objects, e.g. extremely thin samples. Here, we propose a new analytical method to accurately map aspherical valence electron distributions with atom-centered multipolar functions formalism using the whole 4D-STEM dataset. We demonstrate that, with the full dynamical calculations for various sample thicknesses, the method is sensitive not only to the miniscule charge transfer, but also to the atomic site symmetry and aspherical electron orbitals. The process of the refinement is much more robust and reliable than quantitative convergent beam electron diffraction.