Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating PV System Performance with Component Reliability Distributions

A feature developed by Sandia National Laboratories (SNL) for simulating PV system component reliability has been integrated into the National Renewable Energy Laboratory's System Advisor Model (SAM). The PV Reliability Performance Model (PV-RPM) uses fault/failure and repair distributions to estimate impacts to power, energy production and operational costs. Realization results include the number of failures per component, failure rate, O&M costs incurred based on maintenance strategies, and energy lost based on the failure estimates. As the inputs are inherently uncertain and based on probability distributions, the model realizations include statistical confidence intervals to help bracket the probability that the sample interval contains the true mean value of the variable in question. This paper presents the current validation efforts and provides detail on how this feature is utilized in a PV performance model.

14 SOLAR ENERGY↗

Techniques of Final Preseal Visual Inspection

A dissertation is given on the final preseal visual inspection of microcircuit devices to detect manufacturing defects and reduce failure rates in service. The processes employed in fabricating monolithic integrated circuits and hybrid microcircuits, various failure mechanisms resulting from deficiencies in those processes, and the rudiments of performing final inspection are outlined.

Anstead, R. J.↗

An experiment in software reliability: Additional analyses using data from automated replications

A study undertaken to collect software error data of laboratory quality for use in the development of credible methods for predicting the reliability of software used in life-critical applications is summarized. The software error data reported were acquired through automated repetitive run testing of three independent implementations of a launch interceptor condition module of a radar tracking problem. The results are based on 100 test applications to accumulate a sufficient sample size for error rate estimation. The data collected is used to confirm the results of two Boeing studies reported in NASA-CR-165836 Software Reliability: Repetitive Run Experimentation and Modeling, and NASA-CR-172378 Software Reliability: Additional Investigations into Modeling With Replicated Experiments, respectively. That is, the results confirm the log-linear pattern of software error rates and reject the hypothesis of equal error rates per individual fault. This rejection casts doubt on the assumption that the program's failure rate is a constant multiple of the number of residual bugs; an assumption which underlies some of the current models of software reliability. data raises new questions concerning the phenomenon of interacting faults.

Dunham, Janet R.↗

Deconsolidation and Leach Burn Leach of Seven As Irradiated AGR 5/6/7 TRISO Fuel Compacts from Capsules 2, 3, 4, and 5

Seven as-irradiated Advanced Gas Reactor (AGR) 5/6/7 compacts underwent destructive post-irradiation examination via deconsolidation-leach-burn leach at Idaho National Laboratory (INL). The selection of the compacts extended the upper and lower limits of time-average volume-average (TAVA) temperature for compacts that had gone through deconsolidation-leach-burn leach so far. The measured inventories of fission products and actinides in the compact matrix and outer pyrolytic carbon were reported. Results indicated unexpectedly higher rates of fuel kernel leaching compared to compacts from AGR-1 and AGR-2. These failure rates were attributed to damage during post-irradiation sample handling, rather than irradiation itself. AGR-5/6/7 compacts have little or no matrix coverage for some particles at the top and bottom ends of cylindrical fuel compacts, making them more fragile. Sixty particles were randomly sampled from each compact, and the gamma results were reported. Three SiC shells from were identified, one of which showed signs of chemical attack in the high-irradiation temperature compact.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Results of a Prospective Randomized Trial Comparing Concurrent Chemoradiotherapy Plus Adjuvant Chemotherapy With Radiotherapy Alone in Patients With Locoregionally Advanced Nasopharyngeal Carcinoma in Endemic Regions of China

Purpose: A prospective randomized trial was performed to evaluate the efficacy of concurrent chemotherapy and adjuvant chemotherapy in patients with locoregionally advanced nasopharyngeal carcinoma (NPC) in endemic regions of China. Methods and Materials: Between July 2002 and September 2005, 316 eligible patients were randomly assigned to receive either radiotherapy alone (RT) or chemoradiotherapy concurrent with adjuvant chemotherapy (CRT). All patients received 70 Gy in 7 weeks using standard RT portals and techniques. The CRT patients were given concurrent cisplatin (40 mg/m{sup 2} on Day 1) weekly during RT, followed by cisplatin (80 mg/m{sup 2} on Day 1) and fluorouracil (800 mg/m{sup 2} on Days 1-5) every 4 weeks (Weeks 5, 9, and 13) for three cycles after completion of RT. All patients were analyzed by intent-to-treat analysis. Results: The two groups were well-balanced in all prognostic factors and RT parameters. The CRT group experienced significantly more acute toxicity (62.6% vs. 32%, p = 0.000). A total of 107 patients (68%) and 97 patients (61%) completed all cycles of concurrent chemotherapy and adjuvant chemotherapy, with a median follow-up time of 29 months. The 2-year overall survival rate, failure-free survival rate, distant failure-free survival rate, and locoregional failure-free survival rate for the CRT and RT groups were 89.8% vs. 79.7% (p = 0.003), 84.6% vs. 72.5% (p = 0.001), 86.5% vs. 78.7% (p = 0.024), and 98.0% vs. 91.9% (p = 0.007), respectively. Conclusions: This trial demonstrated the significant survival benefits of concurrent chemotherapy plus adjuvant chemotherapy in patients with locoregionally advanced NPC in endemic regions of China.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time Interval From Breast-Conserving Surgery to Breast Irradiation in Early Stage Node-Negative Breast Cancer: 17-Year Follow-Up Results and Patterns of Recurrence

Purpose: A retrospectivechart review was conducted to determine whether the time interval from breast-conserving surgery to breast irradiation (surgery-radiation therapy interval) in early stage node-negative breast cancer had any detrimental effects on recurrence rates. Methods and Materials: There were 566 patients with T1 to T3, N0 breast cancer treated with breast-conserving surgery and breast irradiation and without adjuvant systemic treatment between 1985 and 1992. The surgery-to-radiation therapy intervals used for analysis were 0 to 8 weeks (201 patients), >8 to 12 weeks (233 patients), >12 to 16 weeks (91 patients), and >16 weeks (41 patients). Kaplan-Meier estimates of time to local recurrence, disease-free survival, distant disease-free survival, cause-specific survival, and overall survival rates were calculated. Results: Median follow-up was 17.4 years. Patients in all 4 time intervals were similar in terms of characteristics and pathologic features. There were no statistically significant differences among the 4 time groups in local recurrence (P=.67) or disease-free survival (P=.82). The local recurrence rates at 5, 10, and 15 years were 4.9%, 11.5%, and 15.0%, respectively. The distant disease relapse rates at 5, 10, and 15 years were 10.6%, 15.4%, and 18.5%, respectively. The disease-free failure rates at 5, 10, and 15 years were 20%, 32.3%, and 39.8%, respectively. Cause-specific survival rates at 5, 10, and 15 years were 92%, 84.6%, and 79.8%, respectively. The overall survival rates at 5, 10, and 15 years were 89.3%, 79.2%, and 66.9%, respectively. Conclusions: Surgery-radiation therapy intervals up to 16 weeks from breast-conserving surgery are not associated with any increased risk of recurrence in early stage node-negative breast cancer. There is a steady local recurrence rate of 1% per year with adjuvant radiation alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Once-Weekly, High-Dose Stereotactic Body Radiotherapy for Lung Cancer: 6-Year Analysis of 60 Early-Stage, 42 Locally Advanced, and 7 Metastatic Lung Cancers

Purpose: To explore once-weekly stereotactic body radiotherapy (SBRT) in nonoperable patients with localized, locally advanced, or metastatic lung cancer. Methods and Materials: A total of 102 primary (89 untreated plus 13 recurrent) and 7 metastatic tumors were studied. The median follow-up was 38 months, the average patient age was 75 years. Of the 109 tumors studied, 60 were Stage I (45 IA and 15 IB), 9 were Stage II, 30 were Stage III, 3 were Stage IV, and 7 were metastases. SBRT only was given in 73% (40 Gy in four fractions to the planning target volume to a total dose of 53 Gy to the isocenter for a biologically effective dose of 120 Gy{sub 10}). SBRT was given as a boost in 27% (22.5 Gy in three fractions once weekly for a dose of 32 Gy at the isocenter) after 45 Gy in 25 fractions to the primary plus the mediastinum. The total biologically effective dose was 120 Gy{sub 10}. Respiration gating was used in 46%. Results: The overall response rate was 75%; 33% had a complete response. The overall response rate was 89% for Stage IA patients (40% had a complete response). The local control rate was 82%; it was 100% and 93% for Stage IA and IB patients, respectively. The failure rate was 37%, with 17% within the planning target volume. No Grade 3-4 acute toxicities developed in any patient; 12% and 7% of patients developed Grade 1 and 2 toxicities, respectively. Late toxicity, all Grade 2, developed in 3% of patients. The 5-year cause-specific survival rate for Stage I was 70% and was 74% and 64% for Stage IA and IB patients, respectively. The 3-year Stage III cause-specific survival rate was 30%. The patients with metastatic lung cancer had a 57% response rate, a 27% complete response rate, an 86% local control rate, a median survival time of 19 months, and 23% 3-year survival rate. Conclusions: SBRT is noninvasive, convenient, fast, and economically attractive; it achieves results similar to surgery for early or metastatic lung cancer patients who are older, debilitated, and with comorbidities. Elderly patients and/or patients medically unfit for combined modality therapy with locally advanced disease can find an effective palliative alternative in SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar-cell interconnect design for terrestrial photovoltaic modules

Useful solar cell interconnect reliability design and life prediction algorithms are presented, together with experimental data indicating that the classical strain cycle (fatigue) curve for the interconnect material does not account for the statistical scatter that is required in reliability predictions. This shortcoming is presently addressed by fitting a functional form to experimental cumulative interconnect failure rate data, which thereby yields statistical fatigue curves enabling not only the prediction of cumulative interconnect failures during the design life of an array field, but also the quantitative interpretation of data from accelerated thermal cycling tests. Optimal interconnect cost reliability design algorithms are also derived which may allow the minimization of energy cost over the design life of the array field.

Mon, G. R.↗

Investigation of energy transfer in the ignition mechanism of a NASA standard initiator

The principal objective of the proposed research was to construct a detailed computer model of the NASA Standard Initiator (NSI). The NSI plays a critical role in initiating various pyrotechnic events in the National Space Transportation System and is also used in Shuttle payload applications. Several initiators failed when being tested at very low temperatures (4 to 20 K). During subsequent investigation an unacceptable high failure rate was found even at higher temperatures (100 to 150 K) but the precise cause of failure was not determined. The modelling work was undertaken to investigate reasons for failure and to predict the performance of alternate firing schemes. The work has shown that the most likely cause of failure at low temperature is poor thermal contact between the electrically heated bridgewire and the pyrotechnic charge. This problem may be masked if there is good thermal contact between the bridgewire and the alumina charge cup. The high thermal conductivity of alumina at cryogenic temperatures was overlooked in previous analyses, which assumed that the charge cup acted as a thermal insulator.

Varghese, Philip L.↗

Cryogenic Characterization and Testing of Magnetically-Actuated Microshutter Arrays for the James Webb Space Telescope

Two-dimensional MEMS microshutter arrays (MSA) have been fabricated at the NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST) to enable cryogenic (approximately 35 K) spectrographic astronomy measurements in the near-infrared region. Functioning as a focal plane object selection device, the MSA is a 2-D programmable aperture mask with fine resolution, high efficiency and high contrast. The MSA are close- packed silicon nitride shutters (cell size of 100 x 200 microns) patterned with a torsion flexure to allow opening to 90 degrees. A layer of magnetic material is deposited onto each shutter to permit magnetic actuation. Two electrodes are deposited, one onto each shutter and another onto the support structure side-wall, permitting electrostatic latching and 2-D addressing. New techniques were developed to test MSA under mission-similar conditions (8 K less than or equal to T less than 300K). The magnetic rotisserie has proven to be an excellent tool for rapid characterization of MSA. Tests conducted with the magnetic rotisserie method include accelerated cryogenic lifetesting of unpackaged 128 x 64 MSA and parallel measurement of the magneto-mechanical stiffness of shutters in pathfinder test samples containing multiple MSA designs. Lifetest results indicate a logarithmic failure rate out to approximately 10(exp 6) shutter actuations. These results have increased our understanding of failure mechanisms and provide a means to predict the overall reliability of MSA devices.

King, T. T.↗

Field Programmable Gate Array Reliability Analysis Guidelines for Launch Vehicle Reliability Block Diagrams

Field Programmable Gate Arrays (FPGAs) integrated circuits (IC) are one of the key electronic components in today's sophisticated launch and space vehicle complex avionic systems, largely due to their superb reprogrammable and reconfigurable capabilities combined with relatively low non-recurring engineering costs (NRE) and short design cycle. Consequently, FPGAs are prevalent ICs in communication protocols and control signal commands. This paper will identify reliability concerns and high level guidelines to estimate FPGA total failure rates in a launch vehicle application. The paper will discuss hardware, hardware description language, and radiation induced failures. The hardware contribution of the approach accounts for physical failures of the IC. The hardware description language portion will discuss the high level FPGA programming languages and software/code reliability growth. The radiation portion will discuss FPGA susceptibility to space environment radiation.

Al Hassan, Mohammad↗

ASTROMETRY.NET: BLIND ASTROMETRIC CALIBRATION OF ARBITRARY ASTRONOMICAL IMAGES

We have built a reliable and robust system that takes as input an astronomical image, and returns as output the pointing, scale, and orientation of that image (the astrometric calibration or World Coordinate System information). The system requires no first guess, and works with the information in the image pixels alone; that is, the problem is a generalization of the 'lost in space' problem in which nothing-not even the image scale-is known. After robust source detection is performed in the input image, asterisms (sets of four or five stars) are geometrically hashed and compared to pre-indexed hashes to generate hypotheses about the astrometric calibration. A hypothesis is only accepted as true if it passes a Bayesian decision theory test against a null hypothesis. With indices built from the USNO-B catalog and designed for uniformity of coverage and redundancy, the success rate is >99.9% for contemporary near-ultraviolet and visual imaging survey data, with no false positives. The failure rate is consistent with the incompleteness of the USNO-B catalog; augmentation with indices built from the Two Micron All Sky Survey catalog brings the completeness to 100% with no false positives. We are using this system to generate consistent and standards-compliant meta-data for digital and digitized imaging from plate repositories, automated observatories, individual scientific investigators, and hobbyists. This is the first step in a program of making it possible to trust calibration meta-data for astronomical data of arbitrary provenance.

07 ISOTOPE AND RADIATION SOURCES↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The TDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. No increasing trends were identified for TDPs for the most recent 10-year period: The following decreasing trends were identified for TDPs for the most recent 10-year period: • Standby TDP FTR>1H failure rate • Standby TDP unavailability • Standby MDP total unreliability (8-hour mission) • Standby TDP frequency of FTR>1H events (failures per reactor year) • Normally running TDP frequency of start demands (demands per reactor year) • Normally running TDP frequency of run hours (hours per reactor year).

99 GENERAL AND MISCELLANEOUS↗

A computational fluid dynamics simulation framework for ventricular catheter design optimization

OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter’s small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter’s fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter’s design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter’s inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.

Neurosciences & Neurology↗

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Adaptation for High-Performance Data Transfers

Characteristics of the communication infrastructure determine which action should be taken when tuning data transfer operations in order to obtain high transfer rates. Local area networks and wide area networks have different characteristics, so they demonstrate diverse features in terms of congestion, failure rate, and latency. In most cases, congestion is not a concern in dedicated high bandwidth networks. However, the latency wall in data transfers over high bandwidth connections is still an issue. Enough data should be obtained from the applications and storage layers for high throughput performance. Data transfer optimization has been deeply studied in the literature. However, many of the solutions require kernel level changes that are not preferred by most domain scientists. In this study, we concentrate on application level auto-tuning methodologies that are applied in user-space for better transfer performance. Using multiple data transfer streams is a common technique applied in application layer to increase the network bandwidth utilization [2,5,10]. Instead of a single connection at a time, multiple streams are opened for a single data transfer service. Larger bandwidth in a network is gained with less packet loss rate; concurrent data transfer operations that are initiated at the same time better utilize the network and system resources.

97 MATHEMATICS AND COMPUTING↗