Search NASASearch

SEARCH · Search NASA

Results for “Cryogenic Electrical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,481 records · Page 17

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

xEMU

Effects of Motion Fidelity on Pilot Performance Using Mixed-Reality Visuals

This paper investigates the effects of simulator motion fidelity on pilot performance using mixed-reality visuals. In NASA’s Vertical Motion Simulator, eleven pilots flew a lift-plus-cruise electric vertical takeoff and landing vehicle in a vertiport approach and landing task with four different motion conditions: no motion, small hexapod motion, large hexapod motion, and full motion. The simulator motion condition statistically significantly affected: 1) the severity of cybersickness, 2) motion ratings, 3) final approach and take-off boundary crossing groundspeed, 4) longitudinal touchdown point, and 5) battery time remaining after landing. The findings suggest that motion systems are essential in simulators with virtual- or mixed-reality visuals when it is required to have pilot flying performance similar to that in real flight.

mixed reality

Model Correlation and Thermal Analysis of xEMU Boot at Lunar South Pole Temperatures

The National Aeronautics and Space Administration (NASA) Artemis program plans to send astronauts to the lunar south pole, a region of the moon that is colder than previous lunar missions and low earth orbit operations. The spacesuit boots that will be used on these missions will be directly impacted by these extremely cold temperatures (down to ~50 K). To assess the performance of the Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these extreme temperatures, the boot was tested at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This data was used to correlate thermal models to predict operational performance of the boots on the lunar south pole. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU TVAC test. Data from the test series was used to determine expected thermal conductances within the boot and between the boot and environment. These conductances were used to correlate a Thermal Desktop model of the xEMU boot across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. The correlated model was then used to predict operational performance in the lunar south pole. While the predictions indicate promising evidence for performance of the boots at the 100K test point, there is still substantial uncertainty in performance, particularly at the 48K test point. The results of this test series and model correlation stress the importance of improved testing for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

thermal analysis

Experimental and analytical ion thruster research

The results of further spectroscopic studies on the plume from a 3 cm ion source operated on an argon propellant is reported on. In particular, it is shown that it should be possible to use the spectroscopic technique to measure the plasma density of the ion plume close to the grids, where it is difficult to use electrical probe measurements. How the technique, along with electrical probe measurements in the far downstream region of the plume, can be used to characterize the operation of a three-grid, 15 cm diameter thruster from NASA JPL is outlined. Pumping speed measurements on the Vacuum Research Facility have shown that this facility should be adequate for testing the JPL thruster at pressures in the low 10(exp -5) Torr range. Finally, we describe a simple analytical model which can be used to calculate the grid impingement current which results from charge-exchange collisions in the ion plume.

Wilhelmus M. Ruyten

"Long Life" Dc Brush Motor for Use on the Mars Surveyor Program

DC brush motors have several qualities which make them very attractive for space flight applications. Their mechanical commutation is simple and lightweight, requiring no external sensing and control in order to function properly. They are extremely efficient in converting electrical energy into mechanical energy. Efficiencies over 80% are not uncommon, resulting in high power throughput to weight ratios. However, the inherent unreliability and short life of sliding electrical contacts, especially in vacuum, have driven previous programs to utilize complex brushless DC or the less efficient stepper motors. The Mars Surveyor Program (MSP'98) and the Shuttle Radar Topography Mission (SRTM) have developed a reliable "long life" brush type DC motor for operation in low temperature, low pressure CO2 and N2, utilizing silver-graphite brushes. The original intent was to utilize this same motor for SRTM's space operation, but the results thus far have been unsatisfactory in vacuum. This paper describes the design, test, and results of this development.

David Braun

Hubble Space Telescope nickel-hydrogen battery testing: An update

The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

Whitt, Thomas H.

NASA Weather Balloon Demonstration of an Additively Manufactured Antenna

Additive manufacturing (AM) enables low-cost, lightweight, and geometrically flexible antennas for rapid deployment missions. This work reports a left-hand circularly polarized magneto-electric dipole printed on a Radix dielectric with inkjet silver metallization and demonstrated as a process replacement for NASA weather-balloon RF hardware. By combining substrate fabrication and metallization, AM provides value for unrecoverable or field-replaceable systems. A physics based verification workflow links AM-specific material behavior to electromagnetic performance and yields bounded total, radiation, and mismatch efficiencies. Standard surface-impedance and roughness models failed to reproduce the frequency-dependent radiation loss observed in printed inks, underscoring the need for AM-specific conductor parameterization. Mission testing confirmed TDRSS link closure from NASA’s Columbia Scientific Balloon Facility and validated a repeatable print–measure–fly workflow for bounding RF performance and qualifying AM antennas for field use.

Peter Moschetti

NASA Weather Balloon Demonstration of an Additively Manufactured Antenna

Additive manufacturing (AM) enables low-cost, lightweight, and geometrically flexible antennas for rapid deployment missions. This work reports a left-hand circularly polarized magneto-electric dipole printed on a Radix dielectric with inkjet silver metallization and demonstrated as a process replacement for NASA weather-balloon RF hardware. By combining substrate fabrication and metallization, AM provides value for unrecoverable or field-replaceable systems. A physics based verification workflow links AM-specific material behavior to electromagnetic performance and yields bounded total, radiation, and mismatch efficiencies. Standard surface-impedance and roughness models failed to reproduce the frequency-dependent radiation loss observed in printed inks, underscoring the need for AM-specific conductor parameterization. Mission testing confirmed TDRSS link closure from NASA’s Columbia Scientific Balloon Facility and validated a repeatable print–measure–fly workflow for bounding RF performance and qualifying AM antennas for field use.

Peter Moschetti

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit

SODAs: sparse optimization for the discovery of differential and algebraic equations

Differential-algebraic equations (DAEs) integrate ordinary differential equations (ODEs) with algebraic constraints, providing a fundamental framework for developing models of dynamical systems characterized by time-scale separation, conservation laws and physical constraints. While sparse optimization has revolutionized model development by allowing data-driven discovery of parsimonious models from a library of possible equations, existing approaches for dynamical systems assume DAEs can be reduced to ODEs by eliminating variables before model discovery. This assumption limits the applicability of such methods for DAE systems with unknown constraints and time scales. We introduce sparse optimization for differential-algebraic systems (SODAs), a data-driven method for the identification of DAEs in their explicit form. By discovering the algebraic and dynamic components sequentially without prior identification of the algebraic variables, this approach leads to a sequence of convex optimization problems. It has the advantage of discovering interpretable models that preserve the structure of the underlying physical system. To this end, SODAs improves since SODAs is singular numerical stability when handling high correlations between library terms, caused by near-perfect algebraic relationships, by iteratively refining the conditioning of the candidate library. We demonstrate the performance of our method on biological, mechanical and electrical systems, showcasing its robustness to noise in both simulated time series and real-time experimental data.

DAE

Development of a high fidelity CFD model for solvent evaporation and transport in porous structure during battery electrode drying

An efficient battery manufacturing process is the key to the mass production of Electric Vehicles (EV), in which drying is one of the most energy-intensive steps significantly influencing the battery cell performance. An accurate 3D CFD model for drying is essential for predicting the drying mechanism and optimizing its parameters. By optimizing the drying process, it is possible to reduce energy consumption and cost during battery manufacturing, minimize binder loading and maximize active material loading to achieve superior electrochemical performances and facilitate wider and faster public adoption of EV. This project aims to optimize the drying process during electrode manufacturing by leveraging high-fidelity, porous electrode simulations for solvent evaporation. By optimizing this process, we seek to reduce energy consumption during battery manufacturing, while minimizing binder loading and maximizing active material loading, with the overall goal of enhancing electrical vehicle performance.

Horner, Jeffrey Scott [Sandia National Laboratorie

CO2 Handling & Electrolyzer Efficiency Scaling Evaluator

CHEESE is an interactive dashboard tool for estimating the performance and material requirements of carbon dioxide electrolysis systems. It helps users evaluate how electrode area, current density, product selectivity, gas flow, cell voltage, and the number of cells in a stack affect system operation. The dashboard provides simple and advanced modes so it can be used for both quick estimates and more detailed engineering analysis. Users can estimate product output, carbon dioxide use, electrical power, electrode area, gas and liquid flow rates, energy efficiency, material cost per test, and the effect of scaling from a single cell to a multi cell stack. It also includes tools for examining carbon balance, equipment durability, component replacement, and changes in performance over time. This is intended to help both academia and industry researchers who are either getting into CO2 electrolysis on lab-scale or are trying to establish a larger footprint. CHEESE presents results through tables, charts, and simplified cell and stack diagrams. It is intended to support research planning, experimental design, comparison of operating conditions, and early stage scale up studies.

Prajapati, Aditya [Lawrence Livermore National Lab

Battery cell thermal-conductive coating increases efficiency

Thin coating of high-temperature epoxy resin provides necessary electrical insulation, as well as good thermal conductivity between battery cells. Insulation increases efficiency of nickel-cadmium battery, as it would any multicell battery assembly in which cell-to-cell thermal balance is critical.

Doyle, H. M.

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Wild Blue Yonder Propulsion Schemes

This paper will include a discussion of the ORION concept, several gaseous core nuclear rockets, thermonuclear propulsion utilizing superconducting magnets, and finally a lightweight radioisotope power generation system for electric propulsion. With the exception of the latter concept, all of these schemes have much in common. The initial vehicle weights would be very large - on the order of several million pounds. The payload fractions are high - on the order of 25 to 50 percent of the takeoff weight - for near Earth missions. The development problems would be severe, and, correspondingly, the development costs would be extreme - on the order of many billions of dollars. In addition, the launching problems from Earth would be fantastic - with nuclear radiation hazards and political overtones added for good measure. However, the reward for success would be great. One can contemplate large payload fractions propelled on space missions - with thrust-to-weight ratios, at least in some cases, greater than unity and with specific impulses of several thousand seconds. The mission transportation costs would run in terms of dollars per pound of payload with clear opportunities for reasonable manned expeditions across the solar system. This is the carrot that leads the endorsement of such gigantic projects.

John C Evvard

The standard 20 AH battery

The modular power system, which is the first intended use for the NASA standard battery, is basically a four foot by four foot by eighteen inch box which can handle a complement of three 20 ampere hour batteries or later on the intended use is for three 50 ampere hour batteries to be the full complement. The system is designed to be used as a plug on component on a multi mission modular spacecraft. It has as a design point a basically 1250 watt orbital average load. The way it breaks up in a near earth orbit it would be somewhere around 1,000 watts for everything except 10 minutes, and during any 10 minute period it may go up to a peak of 3,000 watt load. Features of the battery reviewed include criteria to store electrical energy, the battery package, the covers and cases, and electrolytes. The capacities expected are 90 percent, the average cell capacity for 24 C, 90 percent of the actual battery capacity of 19 C, and 85 percent of the actual 25 degree battery capacity at zero discharge voltage for 50 percent DOD new battery is in the vicinity expected or predicted of 26.4 volts.

Zollner, M. T.