Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite Properties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

AGC-1 Sister Specimen Testing Data Report

The AGC-1 irradiation capsule will provide irradiation creep design data and data for the effects of irradiation creep on key physical properties of several candidate graphites for the Next Generation Nuclear Plant (NGNP). A further objective of the AGC-1 creep capsule is to provide design data for the effects of neutron irradiation on the properties of a range of NGNP candidate graphites, Characterization, both non-destructively and destructively, of AGC-1 graphite creep “sister” specimens for the major grades, i.e., NBG-17, NBG-18, H-451, PCEA, IG-110, and IG-430 has been performed and is reported here. The properties measured were: bulk density by mensuration and Hg-immersion; tensile properties, including strength, stress-strain behavior, static Young’s modulus, and strain to failure; compressive properties, including strength, stress-strain behavior, static elastic modulus, and strain to failure; elastic constants, including dynamic Young’s modulus (fundamental frequency method), and sonic elastic constants, including Young’s modulus, shear modulus, and Poisson’s ratio; pore size distribution (by Hg-intrusion); crystal structure (by x-ray diffraction, XRD); specific heat (elevated temperature), and thermal conductivity (elevated temperature). Significant differences were noted in the physical properties between the grades examined and are attributed to factors such as density, structure (filler particle size and pore size) and the forming method. Some difficulties were encountered with mechanical testing of small (sub-standard) size specimens due to volume and grain size-section size effects. These difficulties are well understood and are an inevitable consequence of conducting property evaluations on small irradiation specimens. These data are judged to be sufficient to yield adequate fractional change in properties when combined with post-irradiation characterization data. However, the complication associated with small specimen testing reinforces the need to conduct full characterization programs to establish the baseline design properties of the NGNP candidate graphites. A sufficient body of experimental data has been acquired from the AGC-1 creep “sister” specimens to fully characterize the properties of interest for the major grades included in the AGC-1 capsule. These data, in combination with the pre-irradiation characterization data packages for the actual AGC-1 creep and control specimens, provide a sound and sufficient pre-irradiation data set for determination of the effects of irradiation induced dimensional change and creep strain on the physical properties of the nuclear graphite grades in the AGC-1 capsule.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AGC 2 Irradiated Material Properties Analysis

The Advanced Reactor Technologies Graphite Research and Development Program is conducting an extensive graphite irradiation experiment to provide data for licensing of a high temperature reactor (HTR) design. In past applications, graphite has been used effectively as a structural and moderator material in both research and commercial high temperature gas cooled reactor designs. , Nuclear graphite H 451, used previously in the United States for nuclear reactor graphite components, is no longer available. New nuclear graphite grades have been developed and are considered suitable candidates for new HTR reactor designs. To support the design and licensing of HTR core components within a commercial reactor, a complete properties database must be developed for these current grades of graphite. Quantitative data on in service material performance are required for the physical, mechanical, and thermal properties of each graphite grade, with a specific emphasis on data accounting for the life limiting effects of irradiation creep on key physical properties of the HTR candidate graphite grades. Further details on the research and development activities and associated rationale required to qualify nuclear grade graphite for use within the HTR are documented in the graphite technology research and development plan.

36 MATERIALS SCIENCE↗

Interfacial Effects on the Thermal and Mechanical Properties of Graphite/Copper Composites

Graphite surfaces are not wet by pure copper. This lack of wetting has been responsible for a debonding phenomenon that has been found in continuous graphite fiber reinforced copper matrix composites subjected to elevated temperatures. By suitably alloying copper, its ability to wet graphite surfaces can be enhanced. Information obtained during sessile drop testing has led to the development of a copper-chromium alloy that suitably wets graphite. Unidirectionally reinforced graphite/copper composites have been fabricated using a pressure infiltration casting procedure. P100 pitch-based fibers have been used to reinforce copper and copper-chromium alloys. X-ray radiography and optical microscopy have been used to assess the fiber distribution in the cast composites. Scanning electron microscopy and Auger electron spectroscopy analyses were conducted to study the distribution and continuity of the chromium carbide reaction phase that forms at the fiber/matrix interface in the alloyed matrix composites. The effects of the chromium in the copper matrix on the mechanical and thermal properties of P100Gr/Cu composites have been evaluated through tensile testing, three-point bend testing, thermal cycling and thermal conductivity calculations. The addition of chromium has resulted in an increased shear modulus and essentially zero thermal expansion in the P100Gr/Cu-xCr composites through enhanced fiber/matrix bonding. The composites have longitudinal tensile strengths in excess of 700 MPa with elastic moduli of 393 GPa. After 100 hr at 760 deg C 84 percent of the as-cast strength is retained in the alloyed matrix composites. The elastic moduli are unchanged by the thermal exposure. It has been found that problems with spreading of the fiber tows strongly affect the long transverse tensile properties and the short transverse thermal conductivity of the P100Gr/Cu-xCr composites. The long transverse tensile strength is limited by rows of touching fibers which are paths of easy crack propagation under low tensile loads. The short transverse thermal conductivity is dictated by the fiber/matrix interface. Conduction across this interface has been estimated to be two orders of magnitude lower than that across the composite. This is due to the mechanical, and not chemical, nature of Gr/Cu bond.

Devincent, Sandra Marie↗

Energetics of carbon nanotubes: insights from calorimetry and neutron scattering

Single-wall carbon nanotubes (SWCNTs) are only moderately less stable than graphite, and are significantly more stable than their fullerene counterparts. They are 7 kJ mol-1 metastable relative to graphite, and just 5 kJ mol-1 less stable than diamond. Despite striking differences in vibrational dynamics of carbon atoms in SWCNTs and graphite, their thermodynamic properties at room and higher temperatures are dominated by the same set of high energy vibrations, reflected in very similar vibrational entropies. However, the energetics of SWCNT are governed by counter-acting enthalpic contributions of the diameter-dependent strain induced by the roll-up of graphene sheets into tubes and of carbon-carbon bonding at the edges of graphene sheets in the graphite, but not the specifics of phonon density of states (PDOS).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A “Master Curve” Describing Reaction Inhomogeneity and Plating Onset during Fast-Charging of Graphite Electrodes

Lithium plating in porous graphite electrodes is a major limitation for fast charging. Theoretical evidence suggests plating during fast charging is largely due to inhomogeneous intercalation through the electrode thickness (caused by ionic/mass transfer limitations and inherent thermodynamic properties of the graphite material). Numerical and analytical predictions of plating onset during fast charging have been proposed but not compared directly with experiments. This work validates these model predictions against plating onset measurements via the “dOCV” method in graphite half-cells, for various electrode thicknesses and C-rates. Remarkably, it is shown that experimental and theoretical trends in plating onset (vs C-rate and electrode thickness) collapse to a single “master curve” using a nondimensional “reaction inhomogeneity” parameter. This observation supports the hypothesized reaction inhomogeneity mechanism for accelerating plating onset and provides practical guidance for electrode design. Furthermore, this work develops theory to quantify reaction inhomogeneity in situ directly from voltage V vs capacity Q data, using dQ / dV analysis. Here again, experiments and numerical predictions show good agreement, where peaks that correspond to LiC 6 correlate with plating onset. This work provides experimental validation of theoretical tools that can predict plating onset, aid electrode design, and give insight for plating onset mechanisms during fast charging.

25 ENERGY STORAGE↗

Composite structural materials

Progress is reported in studies of constituent materials composite materials, generic structural elements, processing science technology, and maintaining long-term structural integrity. Topics discussed include: mechanical properties of high performance carbon fibers; fatigue in composite materials; experimental and theoretical studies of moisture and temperature effects on the mechanical properties of graphite-epoxy laminates and neat resins; numerical investigations of the micromechanics of composite fracture; delamination failures of composite laminates; effect of notch size on composite laminates; improved beam theory for anisotropic materials; variation of resin properties through the thickness of cured samples; numerical analysis composite processing; heat treatment of metal matrix composites, and the RP-1 and RP2 gliders of the sailplane project.

Ansell, G. S.↗

Magnetic properties and concurrence for fluid {sup 3}He on kagome lattice

We present the results of magnetic properties and entanglement for kagome lattice using Heisenberg model with two- and three-site exchange interactions in strong magnetic field. Kagome lattice correspond to the third layer of fluid {sup 3}He absorbed on the surface of graphite. The magnetic properties and concurrence as a measure of pairwise thermal entanglement are studied by means of variational mean-field like treatment based on Gibbs-Bogoliubov inequality. The system exhibits different magnetic behaviors depending on the values of the exchange parameters (J{sub 2}, J{sub 3}). We have obtained the magnetization plateaus at low temperatures. The central theme of the paper is comparing the entanglement and magnetic behavior for kagome lattice. We have found that in the antiferromagnetic region behavior of the concurrence coincides with the magnetic susceptibility one.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of orthotropic properties and panel width on the compression strength of graphite-epoxy laminates with holes

An experimental study conducted to evaluate the effect of laminate orthotropic properties and panel width on the compression strength of 48-ply graphite-epoxy laminates with drilled holes is described. The test results are evaluated on the basis of hole size and specimen width and are used in determining parameters necessary for predicting trends using the point stress failure criterion. Good agreement is obtained between experimental and predicted values of failure for panels fabricated from two quasi-isotropic laminates and one orthotropic laminate. The results suggest that panels of different widths having holes that are large in relation to the failure prediction parameter should be included in any test program conducted to develop prediction trends that may be used in design applications.

Rhodes, M. D.↗

Feasibility Assessment of Using Electrical Impedance Tomography for Damage Localization in Graphite Microreactor Components

Microreactors have great potential to decrease capital costs and construction timelines, reducing the barriers to implementing advanced nuclear reactor technologies. However, the lower power output of these microreactors introduces economic challenges if the operation and maintenance costs cannot be reduced sufficiently. Many microreactor concepts use graphite materials for in-core moderator and structural purposes, which will require periodic inspection or, ideally, in situ structural health monitoring. This work describes an initial evaluation of the feasibility of leveraging graphite’s semiconducting properties to perform electrical impedance tomography (EIT) for defect localization. First, a study was performed to identify the best methods for bonding electrical contacts to minimize the effects of contact resistance that interfere with impedance measurements of the graphite. After determining the best bonding approach, electrodes were attached to multiple graphite components with varying geometries (e.g., simple block and more representative microreactor hexagonal block). In parallel, finite element analysis approaches were developed and implemented to analyze the impact of defects and contact resistances and to inform an iterative inverse model for reconstructing the conductivity distribution. The results of this study show that defect localization in graphite components is possible using EIT if a sufficient number of electrodes (to improve spatial resolution) can be bonded using a technique with very low contact resistance and those contact resistances remain stable during reactor operation. If the reactor core and vessel design do not allow electrodes to be bonded during reactor operation, then it may be possible to detach/reattach electrodes between reactor operation and outages if a suitable mechanical connection that offers repeatable contact resistance can be identified. Alternatively, future work could focus on identifying contacts that can survive the harsh reactor operating environment so that contacts do not need to be removed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Carbon nanomaterial produced by microwave exfoliation of graphite oxide: new insights.

We present detailed characterization of graphene-like material obtained through microwave stimulated exfoliation of graphite oxide (GO). Properties of this material were studied by multiple techniques including, among others, X-ray photoelectron spectroscopy, mass-spectroscopy, infrared and Raman spectroscopy, scanning electron microscopy and broadband dielectric spectroscopy. Specific surface area and volume of microwave exfoliated graphite oxide reached 600 m2 g1 and 6 cm3 g1, respectively. It is shown that during such an explosive reduction process the sample emits CO2, CO and H2O and, in some cases, SO2 gases. The resulting reduced material exhibits IR spectra similar to that of graphite and a dc-conductivity of 0.12 S cm1.

Shulga, Y. M.↗

HDG-1 Graphite Preirradiation Data Package Report

This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HDG-1 Graphite Preirradiation Data Package Report

This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Some load limits and self-lubricating properties of plain spherical bearings with molded graphite fiber reinforced polyimide liners to 320 C

Plain spherical bearings with molded liners of self-lubricating graphite fiber-polyimide composite were developed and their dynamic load capacities were determined. Liners were prepared by transfer molding a prepolymer resin-fiber mix into the space between the ball and outer race, the completing polymerization under heat and pressure. Bearing dynamic load capacities were in excess of 140 MPa (20,000 psi) from room temperature to 260 C and about 70 MPa (10,000 psi) at 320 C. Friction coefficients were about 0.20 at room temperatures and light loads and tended to decrease with increasing temperatures and loads to about 0.15. Thermal expansion of the liner at uniform bearing temperatures of 200 C or higher produced a bearing preload which could be alleviated by providing an initial internal diametral clearance of 0.05 to 0.10 mm.

Sliney, H. E.↗

Sensitivity of the coefficients of thermal expansion of selected graphite reinforced composite laminates to lamina thermoelastic properties

An analytical study of the sensitivity of the laminate coefficient of thermal expansion, CTE, to changes in lamina elastic properties has been made. High modulus graphite/epoxy (P75/934, P100/934, P120/934), graphite/aluminum (P100/Al), and graphite/glass (HMS/Gl) composite materials were considered in quasi-isotropic, low thermal stress, and 'near-zero' thermal expansion laminate configurations. The effects of a positive or negative 10 percent change in lamina properties on laminate CTE is strongly dependent upon both the composite material and the laminate configuration. A 10 percent change in all of the lamina properties had very little effect on the laminate CTE of the HMS/Gl composite laminates investigated. The sensitivity and direction of change in the laminate CTE of Gr/934 depended very strongly on the fiber properties. A 10 percent change in the lamina transverse CTE resulted in changes as large as 0.216 ppm/C in the laminate CTE of a quasi-isotropic Gr/934 laminate. No significant difference was observed in the sensitivity of the laminate CTE of the P100/934 and P120/934 composite materials due to changes in lamina properties. Large changes in laminate CTE can result from measured temperature and radiation effects on lamina properties.

Tompkins, S. S.↗