Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

LM193 Dual Differential Comparator Total Ionizing Dose Test Report

The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.

enhanced low dose rate sensitivity (ELDRS↗

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test determined the enhanced low dose rate sensitivity (ELDRS) of the device up to the mission specific dose of 125 krad(Si).

Total Ionizing Dose (TID)↗

Estimating the Noise Dose Range of the NASA X-59 Aircraft in Supersonic Cruise Using PCBoom Propagation Simulations

PCBoom propagation simulations of the NASA X-59 low-boom in supersonic cruise were conducted using near-field CFD pressure waveforms as inputs to estimate the noise dose range. Low-booms were propagated through realistic atmospheric profiles from the Climate Forecast System Version 2 across the USA, and loudness statistics of the low-booms are presented. The near-field waveforms correspond to aircraft configurations expected to produce minimum- and maximum-loudness levels on the ground. The simulations show that the practical Perceived Level noise dose range is 72 to 86.7 dB. Dose ranges for other single event and cumulative sonic boom metrics of interest are also provided.

X-59↗

Development of a Translational Model to Assess the Impact of Opioid Overdose and Naloxone Dosing on Respiratory Depression and Cardiac Arrest

In response to a surge of deaths from synthetic opioid overdoses, there have been increased efforts to distribute naloxone products in community settings. Prior research has assessed the effectiveness of naloxone in the hospital setting; however, it is challenging to assess naloxone dosing regimens in the community/first‐responder setting, including reversal of respiratory depression effects of fentanyl and its derivatives (fentanyls). Here, we describe the development and validation of a mechanistic model that combines opioid mu receptor binding kinetics, opioid agonist and antagonist pharmacokinetics, and human respiratory and circulatory physiology, to evaluate naloxone dosing to reverse respiratory depression. Validation supports our model, which can quantitatively predict displacement of opioids by naloxone from opioid mu receptors in vitro , hypoxia‐induced cardiac arrest in vivo , and opioid‐induced respiratory depression in humans from different fentanyls. After validation, overdose simulations were performed with fentanyl and carfentanil followed by administration of different intramuscular naloxone products. Carfentanil induced more cardiac arrest events and was more difficult to reverse than fentanyl. Opioid receptor binding data indicated that carfentanil has substantially slower dissociation kinetics from the opioid receptor compared with nine other fentanyls tested, which likely contributes to the difficulty in reversing carfentanil. Administration of the same dose of naloxone intramuscularly from two different naloxone products with different formulations resulted in differences in the number of virtual patients experiencing cardiac arrest. This work provides a robust framework to evaluate dosing regimens of opioid receptor antagonists to reverse opioid‐induced respiratory depression, including those caused by newly emerging synthetic opioids.

Pharmacology & Pharmacy↗

Effect of heavy ion irradiation dose rate and temperature on α' precipitation in high purity Fe-18%Cr alloy

Cr-rich alpha prime precipitates (CrRP) induce hardening and embrittlement of FeCr alloys, but the kinetics of CrRP formation due to particle irradiation are not well understood. In this study, Fe18wt.%Cr alloy in solid solution state and pre-aged to produce relatively coarse CrRP was irradiated with 8 MeV Fe ions. The irradiation conditions involved two midrange doses of 0.37 and 3.7 displacements per atom (dpa), a wide range of dose rates (10 -5 –10 -3 dpa/s) and temperatures (300–450 °C). The distributions of CrRP after irradiation were studied with atom probe tomography (APT). The critical irradiation conditions to suppress CrRP formation were identified as 300 °C and 10-3 dpa/s; CrRP formation occurred readily at lower dose rates or higher temperatures. From 0.37 to 3.7 dpa, CrRP were observed to slightly grow at 350 °C and strongly coarsen at 450 °C. Specimens with pre-existing CrRP evolved into a similar precipitate distribution as detected after ion irradiation on solution annealed specimens at 300–350 °C to 0.37 dpa, indicating that the precipitate microstructure approaches a quasi-equilibrium for doses <1 dpa. Limited shrinking of pre-existing CrRP was observed after irradiation at 450 °C to 0.37 dpa, indicating a higher recovery rate at this temperature. Additionally, the evolution of CrRP is quantitatively explained by employing corrections to the historic Nelson-Hudson-Mazey precipitate stability model, and a radiation modified precipitation mechanism is proposed to account for the competition between radiation enhanced diffusion and ballistic dissolution which results in the modifications on both size and solute concentration of CrRP.

36 MATERIALS SCIENCE↗

Formation of carbon homonuclear bonds in β-SiC under neutron irradiation at various temperatures and neutron doses

To elucidate radiation defect processes in SiC, Raman spectroscopy was systematically applied to high-purity, polycrystalline β-SiC that was neutron irradiated at a range of temperature and dose conditions. The analysis specifically focused on formation of carbon homonuclear bonds by irradiation; these bonds were indicated by D and G bands and amorphous carbon peaks. Intensity of the carbon peaks relative to SiC peaks significantly decreased in the case of high temperature and/or high neutron dose of 500 °C to 29 displacements per atom (dpa) and about 800 °C to 1.38 and 29 dpa. The absence of carbon bond peaks under those conditions was explained by growth of stoichiometric defect clusters, consistent with previous atomistic simulations on SiC defect stability. The lack of Raman bands associated with carbon clusters under high-temperature and high-dose radiation conditions accounts for the resistance of SiC to phase separation under irradiation. The findings further suggest that material compositions and chemical properties that are inherently resistant to chemical disordering under high-dose radiation conditions are indicative of the long-term durability of ceramic compounds in radiation environments.

36 MATERIALS SCIENCE↗

Phase instabilities in austenitic steels during particle bombardment at high and low dose rates

Disruption of phase stability by energetic particle bombardment is a major challenge in designing advanced radiation-tolerant alloys and ion beam processing of nanocomposites. Particularly, ballistic dissolution susceptibility of different solute nanocluster species in alloys is poorly understood. Here, low dose rate neutron irradiations were conducted on a Fe-Cr-Ni based austenitic steel in the BOR-60 reactor (9.4 × 10 -7 dpa/s, 318 °C) followed by accelerated dose rate ion irradiations at multiple temperatures ( 10 -3 dpa/s, 380 – 420 °C). Using atom probe tomography, the stability of radiation-enhanced Cu-rich and radiation-induced Ni-Si-Mn-rich nanoclusters was evaluated. During neutron irradiation, Cu-rich clusters nucleated with their core concentrations progressively increasing with dose, while Ni-Si-Mn-rich clusters formed and evolved into G-phase precipitates. Ion irradiations dramatically altered the nanoclusters. Cu-rich clusters were ballistically dissolved, but Ni-Si-Mn-rich clusters remained stable and coarsened with dose at 400 and 420 °C, highlighting that different nanocluster species in a single microstructure can have innately distinct ballistic dissolution susceptibilities. Solute-specific recoil rates were incorporated into the Heinig precipitate stability model, which shows that in addition to radiation-enhanced diffusion, recovery from ballistic dissolution depends on solute concentration gradient near cluster interfaces. Finally, the combined experimental-modeling study quantified the critical temperatures and damage rates where ballistic dissolution dominates for each cluster species.

36 MATERIALS SCIENCE↗

Effect of dose rate on the phase stability of a CrFeNiMn alloy

We report CrFeNi-based multi-principal element alloys (MPEAs) are being considered for nuclear applications because of their potentially superior mechanical properties and irradiation resistance. While the alloys appear stable against phase decomposition during ion irradiation performed at high dose rate, previous electron irradiation and thermal annealing studies suggested that some of them may be susceptible to phase decomposition. Therefore, to clarify the role of dose rate during ion irradiation on phase decomposition, a CrFeNiMn alloy was irradiated using Fe ions at 500 °C with an intermediate dose rate of 10 -4 dpa/s. Transmission electron microscopy and atom probe tomography observations revealed a high number density of NiMn precipitates, cavities, and dislocation loops, which had not previously been observed after ion irradiation at higher dose rates.

36 MATERIALS SCIENCE↗

Specific Gamma-Ray Dose Constants with Current Emission Data

The specific gamma-ray dose constant represents the gamma effective dose rate due to a point source of unit activity of a given nuclide at 1 m. New tabulations of specific gamma-ray dose constants have been made using current gamma emission data from the SCALE 6.2.3 software package and International Commission on Radiological Protection Publication 107, combined with the effective dose per fluence conversion coefficients (antero-posterior orientation) of International Commission on Radiological Protection Publication 116. SCALE data cover 1,264 nuclides, and International Commission on Radiological Protection Publication 107 data include 1,192 nuclides, with only 777 nuclides in common between the two sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation

Bremsstrahlung MeV x rays with high doses are essential for radiography of dense objects. Intense, short-pulse laser-driven MeV x-ray sources offer a promising solution, but understanding how the dose scales with laser intensity is crucial for their development. While theory predicts a square root scaling with laser intensity, experimental verification has been hindered by significant shot-to-shot variations, often exacerbated by long preplasma scale lengths from low laser contrast. Here, we demonstrate low shot-to-shot dose variation and confirm the theoretical scaling using high-contrast OMEGA EP laser interactions with millimeter-thick tantalum foils, achieving MeV x-ray doses up to 5.4 rad at 1 m for E photon > 500 keV. Simulations reveal that the unique focal spot of the OMEGA EP laser enables efficient x-ray generation and reduced variability by facilitating deeper laser penetration into dense plasma, even with shorter preplasma scale lengths. Published by the American Physical Society 2025

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RAIS ICRP 30 Dose Conversion Factors for Radionuclides

Radionuclide dose conversion factors, also known as dose coefficients, are used for radionuclide dose calculations. Routes included are oral, inhalation, and external exposure. Separate datasets are maintained for ICRP 107, 60, and 30. The dose conversion factors from ICRP 30 (https://rais.ornl.gov/cgibin/tools/TOX_search?select=rad30) can be found in FGR 11. Results from all three tools can be downloaded in .xlsx format.

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

RAIS ICRP 60 Dose Conversion Factors for Radionuclides

Radionuclide dose conversion factors, also known as dose coefficients, are used for radionuclide dose calculations. Routes included are oral, inhalation, and external exposure. Separate datasets are maintained for ICRP 107, 60, and 30. The dose conversion factors from ICRP 60 (https://rais.ornl.gov/cgi-bin/tools/TOX_search?select=rad60) can be found in FGR 12. Results from all three tools can be downloaded in .xlsx format.

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

Residual Dose and Environmental Monitoring for the Fermilab Main Injector Tunnel Using the Data Acquisition Logging Engine (Dale)

The Recycler and the Main Injector are part of the Fermilab Accelerator complex used to deliver proton beam to the different experiments. It is very important to control and minimize losses in both machines during operation, to reduce personnel dose from residual activation and to preserve component lifetime. To minimize losses, we need to identify the loss points and adjust the components accordingly. The Data Acquisition Loss Engine (DALE) platform has been developed within the Main Injector department and upgraded throughout the years. DALE is used to survey the entire enclosure for residual dose rates and environmental readings when unrestricted access to the enclosure is possible. Currently DALE has two radiation meters, which are aligned along each machine, so loss points can be identified for both at the same time. DALE attaches to the enclosure carts and is continuously in motion monitoring dose rates and other environmental readings. In this paper we will describe how DALE is used to provide radiation maps of the residual dose rates in the enclosure. We will also compare the loss points with the Beam Loss monitor data.

43 PARTICLE ACCELERATORS↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Saturn Radiation Dose Environment Characterization

To understand the environment where a time-resolved hard x-ray spectrometer (AXIOM) might be fielded, experiments and simulations were performed to analyze the radiation dose environment underneath the Saturn vacuum dome. Knowledge of this environment is critical to the design and placement of the spectrometer. Experiments demonstrated that the machine performance, at least in terms of on-axis dose, has not significantly changed over the decades. Simulations of the off-axis dose were performed to identify possible spectrometer locations of interest. The effects from the source and dome hardware as well as source distributions and angles of incidence on the radiation environment were also investigated. Finally, a unified radiation transport model was developed for two widely used radiation transport codes to investigate the off-axis dose profiles and the time-dependent x-ray energy spectrum. The demonstrated equivalence of the unified radiation transport model between the radiation transport codes allows the team to tie future time-dependent x-ray environment calculations to previous integral simulations for the Saturn facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update to the Finite Cloud Dose Correction Factors in MACCS

In WASH - 1400, external exposure from the finite radioactive cloud (cloudshine) is calculated by assuming that the cloud is semi-infinite, the concentration of radioactive material is uniform, and by using a correction factor to account for these approximations. This correction factor is originally based upon formulations by Healy and depends on the effective size of the plume and the distance from the plume center to the receptor. The range of the finite cloud dose correction factor table from WASH - 1400 developed using Healy formulations can be exceeded in certain situations. When the range of the table is exceeded, no extrapolation is performed; rather interpolation at the edge of the table is performed per WASH - 1400. The tabulated values of these finite cloud dose correction factors from WASH - 1400 and the interpolation at the edge of the table have been used in MACCS since its creation. An expanded table of finite cloud dose correction factors is one way to reduce the need of using interpolation at the edge of the table. The generation of an expanded finite cloud dose correction factor table for future use in MACCS is documented in this report.

54 ENVIRONMENTAL SCIENCES↗

Hanford Site Composite Analysis: Dose Sensitivity Analyses

This environmental calculation file (ECF) documents the methodologies, assumptions, and results of five analyses that evaluate parameter changes to the revised Hanford Site Composite Analysis (CA) (DOE-RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau). Specifically, this ECF describes the impact on total dose and analyte-specific doses for five sensitivity cases where changes to the following exposure-related parameters were implemented – (1) inventory, (2) recharge rate, (3) external dose conversion factors (DCFs) based on Federal Guidance Report (FGR) No. 15 in (EPA-402-R-19-002, Federal Guidance Report No. 15, External Exposure to Radionuclides in Air, Water, and Soil) instead of FGR No. 12 (EPA 402-R-93-081, Federal Guidance Report No. 12, External Exposure to Radionuclides in Air, Water, and Soil) for groundwater pathway scenario; (4) use of mean instead of 95th percentile intake assumptions for groundwater pathway scenario; and (5) consideration of limited sources based on U.S. Department of Energy (DOE) owned waste sites regulated under DOE O 435.1, Radioactive Waste Management. It should be noted that dose assessments for both base and sensitivity cases are based on the all-pathways representative person groundwater exposure scenario presented in DOE/RL-2022-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau.

54 ENVIRONMENTAL SCIENCES↗