Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Hydrogen Detection via a Low-Cost Prototype Fiber-Optic Sensing System

The developed low-cost prototype sensing system successfully detects hydrogen concentrations across a wide range, demonstrating immediate feasibility for commercial deployment. Utilizing fiber-optic technology, the system delivers stable, reproducible performance from parts-per-million levels up to 100% pure H2 environments. Environmental and chemical cross-sensitivity evaluations confirm robust selectivity against methane and temperature changes, establishing its readiness for near-term commercialization.

fiber-optic H2 sensor↗

Defining the Structural Stability Field of Disordered Fluorite Oxides

Fluorite-structured oxides constitute an important class of materials for energy technologies. Despite their high level of structural symmetry and simplicity, these materials can accommodate atomic disorder without losing crystallinity, making them indispensable for uses in environments with high temperature, changing chemical compositions, or intense radiation fields. In this contribution, we present a set of simple rules that predict whether a compound may adopt a disordered fluorite structure. This approach is closely aligned with Pauling’s rules for ionic crystal structures and Goldschmidt’s rules for ionic substitution.

36 MATERIALS SCIENCE↗

Machine learning models for maintenance cost estimation in delivery trucks using diesel and natural gas fuels

The maintenance costs can represent about 15%–60% of the cost of produced goods depending on the type of goods transported. To comply with stringent emissions regulations, diesel engines are incorporated with complex after-treatment systems that demand increased maintenance. The availability of alternative fuels such as natural gas and propane has fostered the natural gas and propane powertrain systems as well as electrification options for heavy- and medium-duty vehicles. A critical barrier to adopting alternative fuel vehicles has been the lack of knowledge on comparative vehicle maintenance/repair costs with conventional diesel. Moreover, the region of operation, the type of vehicle operation, and seasonal temperature changes also affect the duty cycle which impacts the maintenance and repair costs. This study focuses on estimating the cost-per-mile for heavy-duty vehicles using machine learning models such as random forest, xgboost, neural networks, and a super-learner model. The super-learner model achieved an error as low as 0.0068 $/mile for mean absolute error and 0.0086 $/mile for root mean square error with a coefficient of determination/R-Squared of 97.28%. Specifically, the paper investigates the data collected from the maintenance and repair costs associated with delivery trucks using diesel and natural gas fuels. Since the availability of data is the major constraint, we leveraged the data collected by West Virginia University and the partnership with fleet companies. This allows for additional information related to maintenance costs and fleet-specific maintenance practices of alternative fuel vehicles. This study promotes clean fuel technologies and enables fleet management companies to adopt alternative fuel vehicles in case of similar or lower cost of maintenance compared to diesel vehicles resulting in reduced emissions and total cost of ownership.

Katreddi, Sasanka↗

An evolving Coupled Model Intercomparison Project phase 7 (CMIP7) and Fast Track in support of future climate assessment

The Coupled Model Intercomparison Project (CMIP) coordinates community-based efforts to answer key and timely climate science questions, facilitate delivery of relevant multi-model simulations through shared infrastructure, and support national and international climate assessments. Generations of CMIP have evolved through extensive community engagement from punctuated phasing into more continuous support for the design of experimental protocols, infrastructure for data publication and access, and public delivery of climate information. We identify four fundamental research questions motivating a seventh phase of coupled model intercomparison relating to patterns of sea surface temperature change, changing weather, the water–carbon–climate nexus, and tipping points. Key CMIP7 advances include an expansion of baseline experiments, a focus on CO 2 -emissions-driven experiments, sustained support for community MIPs, periodic updating of historical forcings and diagnostics requests, and a collection of prioritized experiments, or the “Assessment Fast Track”, drawn from community MIPs to support climate research, assessment, and service goals across prediction and projection, characterization, attribution, and process understanding.

Environmental sciences↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

42 ENGINEERING↗

High command fidelity electromagnetically driven calorimeter

An example apparatus can comprise an emitter to emit radio frequency radiation, an absorber that changes temperature based on emissions from the emitter, and one or more sensors to measure a temperature difference between a sample and a reference coupled to the absorber.

42 ENGINEERING↗

Neutron generation using pyroelectric crystals

According to one embodiment, a method for producing a directed neutron beam includes producing a voltage of negative polarity of at least −100 keV on a surface of a deuterated or tritiated target in response to a temperature change of a pyroelectric crystal of less than about 40° C., the pyroelectric crystal having the deuterated or tritiated target coupled thereto, pulsing a deuterium ion source to produce a deuterium ion beam, accelerating the deuterium ion beam to the deuterated or tritiated target to produce a neutron beam, and directing the ion beam onto the deuterated or tritiated target to make neutrons using at least one of a voltage of the pyroelectric crystal, and a high gradient insulator (HGI) surrounding the pyroelectric crystal. The directionality of the neutron beam is controlled by changing the accelerating voltage of the system. Other methods are presented as well.

Tang, Vincent↗

Effectiveness-weighted control of cooling system components

Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.

Campbell, Levi A.↗

Thermally-Induced Breakouts: Insights from True-Triaxial Tests with Acoustic Emission Monitoring

Borehole breakouts are used to constrain the magnitude of maximum horizontal stress. However, when the borehole wall strength is higher than the in situ tangential stress, borehole wall failure does not develop. Additional compressive stress can be induced by heating borehole walls. To validate this concept experimentally, we conducted room-temperature and elevated temperature true-triaxial tests on Berea sandstone and Niagaran dolomite samples. We used acoustic emission sensors to capture the onset of breakout development, and we measured the temperature close to borehole wall to assess the magnitude of induced thermal hoop stress. The test results show that within a specific rock type, the breakouts develop in similar manner in room-temperature and elevated-temperature tests. Therefore, the maximum horizontal stress can be constrained from the following dataset: critical tangential stress at which breakout develops, minimum horizontal stress, elastic and thermal properties, and temperature change at the borehole wall.

Trzeciak, Maciej↗

Mapping Post-Climate Change Biogeographical Regions with Deep Latent Variable Models

Forecasting future changes to biodiversity due to shifts in climate is challenging due to nonlinear interactions between species as recorded in their presence/absence data. This work proposes using variational autoencoders with environmental covariates to identify low-dimensional structure in species’ joint co-occurrence patterns and leveraging this simplified representation to provide multivariate predictions of their habitat extent under future climate scenarios. We pursue a latent space clustering approach to map biogeographical regions of frequently co-occurring species and apply this methodology to a dataset from northern Belgium, generating predictive maps illustrating how these regions may expand or contract with changing temperature under a future climate scenario.

Krapu, Chris↗

Development and Validation of Resistance-Capacitance Model (RCM) for Phase Change Material (PCM) Embedded in 3D Periodic Structures

The low thermal conductivity of Phase Change Materials (PCM) can be improved with extended surfaces such as additively manufactured 3D periodic lattice structures. Three different aluminum alloy-based lattices (base sizes 10, 20, and 40 mm) with average porosity of 0.95 filled with paraffin wax, with a nominal phase change temperature of 55°C, were experimentally investigated. In this work, a computationally efficient 2D Resistance Capacitance-based model (RCM) was developed for predicting the thermal characteristics of these geometries. Non-uniform porosity in the PCM-metal domain was estimated using image processing and served as model input. The solver does not solve for higher-order physics as in CFD but still can provide a good prediction of thermal resistance and energy storage at a very low computational cost. The simulation-to-real-time factor for this geometry is of the order of 10-4, while CFD simulations typically have a real-time factor greater than 1. The model was validated against the experimental data for melting under three different heat fluxes (6250 W/m2, 12500 W/m2, and 18750 W/m2). The mean deviation of the predicted average PCM temperature was between 1.34 K-2.81 K for different cases. The maximum average temperature deviation of 5.45 K was observed for the 20 mm geometry at the highest heat flux test condition. The effects of natural convection were neglected in the model, but the predicted PCM temperature and energy storage still showed good agreement with the experimental data.

25 ENERGY STORAGE↗

Coated fiber optic chemical and radiation sensors

Distributed fiber optic chemical and radiation sensors formed by coating the fibers with certain types of response materials are provided. For distributed chemical sensors, the coatings are reactive with the targets; the heat absorbed or released during a reaction will cause a local temperature change on the fiber. For distributed radiation sensors, coating a fiber with a scintillator enhances sensitivity toward thermal neutrons, for example, by injecting light into the fiber. The luminescent components in these materials are taken from conjugated polymeric and oligomeric dyes, metal organic frameworks with sorbed dyes, and two-photon-absorbing semiconductors. The compositions may exhibit strong gamma rejection. Other scintillators combining luminescent materials with neutron converters are available. With a multiple-layer coating, it may be possible to identify the presence of both neutrons and gamma rays, for example. Coatings may be applied during manufacture or in the field.

Lamberti, Vincent E.↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Temporal variabilities of soil carbon dioxide fluxes from cornfield impacted by temperature and precipitation changes through high-frequent measurement and DAYCENT modelling

Soil carbon dioxide (CO 2 ) emissions from the field of corn (Zea mays L.) play an important role in global warming. This study investigated temporal variability of soil CO 2 fluxes (R s ) with soil temperature (T s ) and moisture (θ) and built DAYCENT models for predicting future impacts of climate changes on R s using the measured high-frequency data. R s trend was tested by Mann–Kendall and Sen Estimator. Predicted R s s under different climate scenarios were compared using Parallel-line Analysis. Herein, the findings indicated that daily R s exponentially increased with T s constrained by θ. During the θ of 27–31%, there was a strong exponential relationship between R s and T s , but the relationship was weaker for the θ of 38–41% and 22–26%. Soil environmental index (SEI, T s × θ) significantly impacted R s with linear regression R s 0.5 = 0.4599 + 0.002059 × SEI in 2008, 2009 and 2011. At the diurnal scale, there were different trends in R s s and relationships among R s and T s and θ in different years. Predicted yearly R s s, root R s s and corn yield in 2014–2049 increased with an increase in temperature scenarios, but the R s s significantly increased as temperature rose by 1°C or higher. Predicted yearly R s s, root R s s and yield reduced with precipitation scenario increase, and the root R s s and yield significantly diminished as precipitation increased by 15 and 30%. Predicted yearly R s from cornfields had a significantly increasing trend. Future research is needed to explore methods for mitigating cornfield R s and evaluating sensitivities of different cropland R s s to temperature changes.

54 ENVIRONMENTAL SCIENCES↗