Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A short pulse of mechanical force induces gene expression and growth in MC3T3-E1 osteoblasts via an ERK 1/2 pathway

Physiological mechanical loading is crucial for maintenance of bone integrity and architecture. We have calculated the strain caused by gravity stress on osteoblasts and found that 4-30g corresponds to physiological levels of 40-300 microstrain. Short-term gravity loading (15 minutes) induced a 15-fold increase in expression of growth-related immediate early gene c-fos, a 5-fold increase in egr-1, and a 3-fold increase in autocrine bFGF. The non-growth-related genes EP-1, TGF-beta, and 18s were unaffected by gravity loading. Short-term physiological loading induced extracellular signal-regulated kinase (ERK 1/2) phosphorylation in a dose-dependent manner with maximum phosphorylation saturating at mechanical loading levels of 12g (p < 0.001) with no effect on total ERK. The phosphorylation of focal adhesion kinase (FAK) was unaffected by mechanical force. g-Loading did not activate P38 MAPK or c-jun N-terminal kinase (JNK). Additionally, a gravity pulse resulted in the localization of phosphorylated ERK 1/2 to the nucleus; this did not occur in unloaded cells. The induction of c-fos was inhibited 74% by the MEK1/2 inhibitor U0126 (p < 0.001) but was not affected by MEK1 or p38 MAPK-specific inhibitors. The long-term consequence of a single 15-minute gravity pulse was a 64% increase in cell growth (p < 0.001). U0126 significantly inhibited gravity-induced growth by 50% (p < 0.001). These studies suggest that short periods of physiological mechanical stress induce immediate early gene expression and growth in MC3T3-E1 osteoblasts primarily through an ERK 1/2-mediated pathway.

NASA Discipline Cell Biology↗

The impact of hydrogen contamination on the Total Dose Response of Linear Bipolar Microcircuits

Recent enhanced low dose rate sensitivity (ELDRS) investigations carried out by RLP Research, Crane, Arizona State University (ASU), and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar microcircuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunity to improve device performance. The objectives of this program are 1) to investigate and confirm the causal relationship between packaging recipes, hydrogen contamination, and total dose response of linear bipolar microcircuits; and 2) to develop a guideline that will take into account these effects at the radiation level for future NASA space missions. This program is geared to benefit all future NASA space missions using bipolar or BiCMOS linear devices.

McClure, Steve S.↗

Space Radiation Environments Overview for MSFC Programs

Provide overview of Space Radiation Sources, Environments, Interactions with Electronic Devices - Radiation Sources - Solar Energetic Particles (SEP) and Solar Particle Events (SPE) - Galactic Cosmic Rays (GCR) - Radiation Environments - Van Allen belts - Beyond the belts - Reference SLS-SPEC-159 Rev G: Design Specification for Natural Environment (DSNE) - Interactions with Electronic Devices - Ionizing - Nonionizing - Internal Charging

Radiation Sources↗

Radiation environment of Spacelab-1

The results of passive and active radiation measurements on Spacelab-1 are reported. Spacelab-1 was flown on the STS-9 mission, orbited at an altitude of 241 km, with an inclination of 57 deg and 240 hours of flight time. Approximately thirty passive detectors deployed inside the module, in the access tunnel, and outside on the pallet made possible the radiation measurements. The various forms of radiation measured were a low linear energy transfer component ranging from 94 to 133 mrads inside the module (average dose rate of 10.0 mrads/day; about twice the rate of earlier shuttle flights), an average mission dose-equivalent rate of about 18.5 mrem/day (six times higher than earlier flights), accumulated doses of 125 and 128 mrads and a yield of 17 and 12 mrads for passages through the South Atlantic Anomaly. Spacelab-1, because of its low altitude and short duration, was relatively benign in terms of total radiation dose. Some of the measurements such as high-LET particles and neutrons have biological significance and potential effects on future experiments.

Benton, E. V.↗

Radiation Hardness Study on SiC Power MOSFETs

As an emerging technology, silicon carbide (SiC) power MOSFETs are showing great potential for higher temperature/power rating, higher efficiency, and reduction in size and weight, which makes this technology ideal for high temperature, harsh environment applications such as downhole, medical, avionic, or even space applications. Radiation tolerance therefore becomes a critical aspect of the device performance in such environments. In this work, we explored radiation hardness of SiC devices to total ionizing dose (TID), neutron-induced single-event burnout (SEB), and heavy-ion induced single-event effects (SEE).

SiC↗

Proton radiation effects on multi-pinned-phased CCDs

Three Tektronix 1024 x 1024 multi-pinned-phased (MPP) charge coupled devices were irradiated with protons to obtain data on CCD performance degradation in a proton radiation environment. The devices were irradiated with a spectrum of energies up to 120 MeV, simulating the total radiation dose of a long-term space experiment. Basic parameters such as charge transfer efficiency, dark current, noise, and full well were measured before and after irradiation. A test was also performed to determine the effectiveness of various thicknesses of tantalum shielding in protecting the CCD from damage. Dark current increase and CTE degradation were the most noticeable effects of proton radiation. This paper will present the objectives, test data, and conclusions of the proton testing, and will identify future testing to be performed.

Murata-Seawalt, D.↗

The Effects of Low Dose-Rate Ionizing Radiation on the Shapes of Transients in the LM124 Operational Amplifier

Shapes of single event transients (SETs) in a linear bipolar circuit (LM124) change with exposure to total ionizing dose (TID) radiation. SETs shape changes are a direct consequence of TID-induced degradation of bipolar transistor gain. A reduction in transistor gain causes a reduction in the drive current of the current sources in the circuit, and it is the lower drive current that most affects the shapes of large amplitude SETs.

Buchner, Stephen↗

Advanced p-MOSFET Ionizing-Radiation Dosimeter

Circuit measures total dose of ionizing radiation in terms of shift in threshold gate voltage of doped-channel metal oxide/semiconductor field-effect transistor (p-MOSFET). Drain current set at temperature-independent point to increase accuracy in determination of radiation dose.

Buehler, Martin G.↗

Evaluation of SPE and GCR Radiation Effects in Inflatable, Space Suit and Composite Habitat Materials Project

The radiation resistance of polymeric and composite materials to space radiation is currently based on irradiating materials with Co-60 gamma-radiation to the equivalent total ionizing dose (TID) expected during mission. This is an approximation since gamma-radiation is not truly representative of the particle species; namely, Solar Particle Event (SPE) protons and Galactic Cosmic Ray (GCR) nucleons, encountered in space. In general, the SPE and GCR particle energies are much higher than Co-60 gamma-ray photons, and since the particles have mass, there is a displacement effect due to nuclear collisions between the particle species and the target material. This effort specifically bridges the gap between estimated service lifetimes based on decades old Co-60 gamma-radiation data, and newer assessments of what the service lifetimes actually are based on irradiation with particle species that are more representative of the space radiation environment.

Waller, Jess M.↗

Kinetic Monte Carlo simulations of aging in δ -Pu

We have developed a first-passage kinetic Monte Carlo approach for materials aging to investigate the sensitivity of void swelling to model parameters, including helium bubble density and size distribution. In addition to explicitly accounting for the spatial distribution of individual point defects, bubbles, and voids, our approach can simulate total doses equivalent to 100 years of natural aging on statistically representative volumes of materials. This technique enables us to study the effects on swelling and radiation damage evolution due to temperature and dose rate (as altered in artificially aged experiments), differences in effective interaction radii between vacancies and interstitials, and varying defect diffusion activation energies, while providing more detailed information than previous rate-equation based approaches. In conclusion, our results indicate that spatial effects that are not modeled in mean-field rate theories could play a significant role in void swelling initiation and growth for certain regimes of model parameters.

Actinides↗

Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics

We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. We also present data on the susceptibility of parts to functional degradation resulting from total ionizing dose at low dose rates (0.003-0.33 Rads(Si)/s). Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog to Digital Converters (ADCs), Digital to Analog Converters (DACs), and DC-DC converters, among others.

OBryan, Martha V.↗

Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage Measured in Metaphase and Interphase Human Lymphocytes

Chromosome aberrations were investigated in human lymphocytes after in vitro exposure to 1H-, 3He-, 12C-, 40Ar-, 28Si-, 56Fe-, or 197Au-ion beams, with LET ranging from approximately 0.4-1393 keV/microm in the dose range of 0.075-3 Gy. Dose-response curves for chromosome exchanges, measured at the first mitosis postirradiation using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosomal damage with respect to low- or high-dose-rate gamma rays. Estimates of RBEmax values for mitotic spreads, which ranged from near 0.7 to 11.1 for total exchanges, increased with LET, reaching a maximum at about 150 keV/microm, and decreased with further increase in LET. RBEs for complex aberrations are undefined due to the lack of an initial slope for gamma rays. Additionally, the effect of mitotic delay on RBE values was investigated by measuring chromosome aberrations in interphase after chemically induced premature chromosome condensation (PCC), and values were up to threefold higher than for metaphase analysis.

NASA Discipline Radiation Health↗

Late ophthalmological complications after total body irradiation in non-human primates

PURPOSE: To investigate the long-term effects of total body irradiation (TBI) on the incidence and time course of ocular complications. MATERIALS AND METHODS: Rhesus monkeys treated with TBI photon doses up to 8.5 Gy and proton doses up to 7.5 Gy were studied at intervals up to 25 years post-irradiation. They were compared with control groups with a similar age distribution. Cataract formation and ocular fundus lesions were scored according to a standardized protocol. Fluorescein angiography and histopathology was performed in selected animals. RESULTS: Cataract formation occurred after a latent period of 3-5 years. Significant cataract induction was observed for photon-doses of 8 and 8.5 Gy and beyond 20 years after proton irradiation. The severity of the lesions represents significant impairment of vision and would require cataract surgery if similar results occurred in human bone marrow transplant patients. Fluorescein angiography demonstrated a normal pattern of retinal vessels in 13 out of 14 animals (93%) from the irradiated group and in eight out of nine animals (89%) from the control group. No additional lesions apart from age-related degenerative changes could be demonstrated. Histological evaluation revealed no radiation-associated vasculopathy. CONCLUSIONS: Radiation alone for doses up to 8.5 Gy of photons does not carry a potential risk for fundus pathology, whereas clinically important cataract induction should be anticipated within 5 years after photon doses of 8.0 and 8.5 Gy and proton doses in excess of 2.5 Gy.

NASA Discipline Radiation Health↗

On the Radiation Effects of Strontium Ions on Satellite Solar Cells in Low Earth Orbits

This study focuses on the radiation effects 19 of Sr + ions—generated from high-altitude nuclear explosions (HANE)—on satellite solar cells in low-Earth orbits (LEO). Along four selected satellite orbits, ion fluences are sampled inside the evolving Sr + distributions for days, determined from our newly developed HANE environment model. These fluences, along with the help of radiation transport codes including the MULASSIS and SRIM models, enable us to quantify the radiation damages by determining the values of total ionizing doses and the equivalent 1 MeV electron fluences for displacement damages. Comparing the dose values to existing experimental data, we conclude that HANE-generated Sr + ions have limited darkening effects to quartz solar cell coverglasses in LEO with apogees of 100s to 1000 km. In addition, with the extremely high equivalent fluences, we also conclude that these Sr+ ions may cause severe or even fatal displacement damage to exposed solar photovoltaic (PV) cells on satellites in LEO. The radiation effects of Sr + ions are much less significant for the orbits with high apogees beyond ten thousand km. We also conducted model parameter sensitivity studies on the charge exchange cross-sections, neutral atmosphere density profiles and explosion local time positions, and the above conclusions stay unchanged. The methodology developed in this study can be extended to other HANE-generated heavy ion species in the future.

14 SOLAR ENERGY↗

Radiation effects on atherosclerosis in atomic bomb survivors: a cross-sectional study using structural equation modeling

Past reports indicated that total-body irradiation at low to moderate doses could be responsible for cardiovascular disease risks, but the mechanism remains unclear. The purpose of this study was to investigate the association between radiation exposure and atherosclerosis, an underlying pathology of cardiovascular diseases, in the Japanese atomic bomb survivors. We performed a cross-sectional study measuring 14 clinical-physiological atherosclerosis indicators during clinical exams from 2010 to 2014 in 3274 participants of the Adult Health Study cohort. Multivariable analyses were performed by using a structural equation model with latent factors representing underlying atherosclerotic pathologies: (1) arterial stiffness, (2) calcification, and (3) plaque as measured with indicators chosen a priori on the basis of clinical-physiological knowledge. Radiation was linearly associated with calcification (standardized coefficient per Gy 0.15, 95 % confidence interval: CI [0.070, 0.23]) and plaque (0.11, 95 % CI [0.029, 0.20]), small associations that were comparable to about 2 years of aging per Gy of radiation exposure, but not with arterial stiffness (0.036, 95 % CI [-0.025, 0.095]). The model fitted better and had narrower confidence intervals than separate ordinary regression models explaining individual indicators independently. The associations were less evident when the dose range was restricted to a maximum of 2 or 1 Gy. By combining individual clinical-physiological indicators that are correlated because of common, underlying atherosclerotic pathologies, we found a small, but significant association of radiation with atherosclerosis.

59 BASIC BIOLOGICAL SCIENCES↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗