Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sensitivity Enhancement in Photoconductive Light Field Sampling

Abstract The emerging field of lightwave electronics is driving optoelectronic information processing beyond current classical limitations and has the potential to eventually reach petahertz frequencies. One of the major obstacles in reaching not only higher switching frequencies but also higher repetition rates with low‐power light sources is the efficiency of related devices. A device is presented based on a multilayered material that shows a 13‐fold enhancement in terms of converting light to electric current compared to bulk solids. Furthermore, the device exhibits an almost flat intensity response within its working range. The outstanding properties of engineered multilayered devices promise to push technology for lightwave electronics applications.

47 OTHER INSTRUMENTATION↗

Direct Visualization and Manipulation of Tunable Quantum Well State in Semiconducting Nb 2 SiTe 4

We report quantum well states (QWSs) can form at the surface or interfaces of materials with confinement potential. They have broad applications in electronic and optical devices such as high mobility electron transistor, photodetector, and quantum well laser. The properties of the QWSs are usually the key factors for the performance of the devices. However, direct visualization and manipulation of such states are, in general, challenging. In this work, by using angle-resolved photoemission spectroscopy (ARPES) and scanning tunneling microscopy/spectroscopy (STM/STS), we directly probe the QWSs generated on the vacuum interface of a narrow band gap semiconductor Nb 2 SiTe 4 . Interestingly, the position and splitting of QWSs could be easily manipulated via potassium (K) dosage onto the sample surface. Our results suggest Nb 2 SiTe 4 to be an intriguing semiconductor system to study and engineer the QWSs, which has great potential in device applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled removal of hydrogen atoms from H-terminated silicon surfaces

The controlled formation of dangling bond structures on a H-terminated silicon surface is the first step in an atomically precise method of fabrication of silicon quantum electronic devices. An ultrahigh vacuum scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from a Si(100)-2x1:H surface by injecting electrons with the sample held at a positive bias voltage. The authors propose a lithography method that allows the STM to operate under negative bias imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative bias voltage to deliver the required energy for hydrogen removal. The resulting current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM’s feedback control loop. The authors show that the chance of tip-sample crash during the lithography process is reduced by employing this method. They also demonstrate that this approach offers a significant potential for controlled and precise removal of H atoms from a H-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

42 ENGINEERING↗

Quantum advantages for Pauli channel estimation

We show that entangled measurements provide an exponential advantage in sample complexity for Pauli channel estimation, which is both a fundamental problem and a practically important subroutine for benchmarking near-term quantum devices. The specific task we consider is to simultaneously learn all the eigenvalues of an n-qubit Pauli channel to ±ε precision. We give an estimation protocol with an n-qubit ancilla that succeeds with high probability using only O(n/ε 2 ) copies of the Pauli channel, while proving that any ancilla-free protocol (possibly with adaptive control and channel concatenation) would need at least Ω(2 n/3 ) rounds of measurement. We further study the advantages provided by a small number of ancillas. For the case that a k-qubit ancilla (k≤n) is available, we obtain a sample complexity lower bound of Ω(2 (n-k)/3 ) for any nonconcatenating protocol, and a stronger lower bound of Ω(n 2n-k ) for any nonadaptive, nonconcatenating protocol, which is shown to be tight. We also show how to apply the ancilla-assisted estimation protocol to a practical quantum benchmarking task in a noise-resilient and sample-efficient manner, given reasonable noise assumptions. Our results provide a practically interesting example for quantum advantages in learning and also bring insights for quantum benchmarking.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sequential Bayesian inference of transition rates in the hidden Markov model for multi-state system degradation

The more easily available system performance data and advances in data analytics have provided us with opportunities to optimize maintenance programs for engineered systems, for example nuclear power plants. One key task in maintenance optimization is to obtain an accurate model for system degradation. Here, in this research, we propose a Bayesian method to address this problem. Noting that systems usually exhibit multiple states and that the actual state of a system usually is not directly observable, in the method we first model the system degradation process and the observation process based on a hidden Markov model. Then we develop a sequential Bayesian inference algorithm based on importance sampling and the forward algorithm to infer the posterior distributions of the transition rates in the hidden Markov model based on available observations. The proposed Bayesian method allows us to take advantage of evidence from multiple sources, and also allows us to perform Bayesian inference sequentially, without the need to use the entire history of observations every time new observations are collected. We demonstrate the proposed method using both synthetic data for a nuclear power plant feedwater pump and realistic data for a nuclear power plant chemistry analytical device.

42 ENGINEERING↗

A Generic Sacrificial Layer for Wide-Range Freestanding Oxides with Modulated Magnetic Anisotropy

Freestanding oxide nanomembranes have promising applications because of their novel electronic states and flexible crystalline structures. Several materials have been developed as sacrificial layers to exfoliate thin films from substrates via wet-etching. However, these materials face great challenges in terms of either complicated crystalline structures or corrosive solutions. Herein, a new sacrificial material, SrCoO 2.5 , is presented, which can be coherently grown with wide-range strains and crystalline orientations and is also soluble in eco-friendly solutions such as acetic acid, vinegar, and even carbonated drinks. With SrCoO 2.5 as the sacrificial layer, high-quality freestanding ferromagnetic SrRuO 3 membranes are achieved from wide-range epitaxial strains and different crystalline orientations. By investigating the evolution of the magnetic properties of these samples, it is discovered that epitaxial strain causes a distinct modification of the magnetic anisotropy of (001) pc -oriented SrRuO 3 samples, while its influence on the (110) pc and (111) pc samples is insignificant. This study not only demonstrates the freestanding SrRuO 3 as a promising material for flexible spintronic devices, but also offers a great opportunity to engineer a wide range of strained and oriented complex oxides for novel freestanding electronics using this newly developed sacrificial material.

36 MATERIALS SCIENCE↗

Detection of a multi–disease biomarker in saliva with graphene field effect transistors

Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes, and Sjogren’s syndrome. However, the lack of a rapid, cheap, accurate, and easy-to-use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label-free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G-FETs) as a transducer and specific RNA aptamers as a probe. The binding of CA1 with aptamers resulted in a positive shift in Dirac voltage V D of the G-FETs, the magnitude of which depended on target concentration. These aptameric G-FET biosensors showed the binding affinity (K D ) of ~2.3 ng/ml (70 pM), which is four orders lower than that reported using a gel shift assay. This lower value of K D enabled us to achieve a detection range (10 pg/ml - 100 ng/ml) which is well in line with the clinically relevant range. These highly sensitive devices allowed us to further prove their clinical relevance by successfully detecting the presence of CA1 in human saliva samples. In conclusion, the utilization of this label-free biosensor could facilitate the early stage identification of various diseases associated with changes in concentration of CAs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deposition-Dependent Coverage and Performance of Phosphonic Acid Interface Modifiers in Halide Perovskite Optoelectronics

In this work, we study the effect of various deposition methods for phosphonic acid interface modifiers commonly pursued as self-assembled monolayers in high-performance metal halide perovskite photovoltaics and light-emitting diodes. We compare the deposition of (2-(3,6-diiodo-9H-carbazol-9-yl)ethyl)phosphonic acid onto indium tin oxide (ITO) bottom contacts by varying three parameters: the method of deposition, specifically spin coating or prolonged dip coating; ITO surface treatment via HCl/FeCl3 etching; and use in combination with a second modifier, 1,6-hexylenediphosphonic acid. We demonstrate that varying these modification protocols can impact time-resolved photoluminescence carrier lifetimes and quasi-Fermi level splitting of perovskite films deposited onto the phosphonic acid-modified ITO. Ultraviolet photoelectron spectroscopy shows an increase in the effective work function after phosphonic acid modification and clear evidence for photoemission from carbazole functional groups at the ITO surface. We used X-ray photoelectron spectroscopy to probe differences in phosphonic acid coverage on the metal oxide contact and show that perovskite samples grown on ITO with the highest phosphonic acid coverage exhibit the longest carrier lifetimes. Finally, we establish that device performance follows these same trends. These results indicate that the reactivity, heterogeneity, and composition of the bottom contact help to control recombination rates and therefore power conversion efficiencies. ITO etching, prolonged deposition times for phosphonic acids via dip coating, and the use of a secondary, more hydrophilic bisphosphonic acid all contribute to improvements in surface coverage, carrier lifetime, and device efficiency. Furthermore, these improvements each have a positive impact, and we achieve the best results when all three strategies are implemented.

contact engineering↗

Measurement of phonon angular momentum

In condensed matter, angular momentum is intimately related to the emergence of topological quantum states, including chiral superconductivity, quantum spin liquids and various chiral quasiparticles. Recently, it has been predicted that microscopic lattice excitations, known as phonons, can carry finite angular momentum, leading to specific physical properties of materials. However, phonon angular momentum has not yet been observed directly. Here, in this study, we demonstrate that angular momentum conservation results in a macroscopic mechanical torque when applying a time-reversal symmetry-breaking thermal gradient along the chiral axis of single-crystal tellurium. We probe this torque using a cantilever-based device and establish that it changes sign by flipping the chirality or thermal gradient. This behavior disappears in polycrystalline samples that lack a preferred chirality. Our experimental results align well with theoretical calculations. We provide compelling evidence for phonon angular momentum, which might enable quantum states with potential applications in microelectronics.

36 MATERIALS SCIENCE↗

Optimizing Charge-coupled Device Readout Enabled by the Floating-gate Amplifier

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future space-based imaging of extremely faint objects on missions such as the Habitable Worlds Observatory. Building upon the capability of the Skipper CCD to achieve deeply sub-electron noise floors, MAS CCDs utilize multiple floating-gate amplifiers along the serial register to increase the readout speed by a factor of the number of output nodes compared to a Skipper CCD. We introduce and experimentally demonstrate on a 16-channel prototype device new readout techniques that exploit the MAS CCD’s floating-gate amplifiers to optimize the correlated double sampling by resetting once per line instead of once per pixel. With this new mode, we find an optimal filter to subtract the noise from the signal during read out. We also take advantage of the MAS CCD’s structure to tune the read time by independently changing integration times for the signal and reference level. Together with optimal weighted averaging of the 16 outputs, these approaches enable us to reach a sub-electron noise of 0.9 e − rms pix −1 at 19 μs pix −1 for a single charge measurement per pixel—simultaneously giving a 30% faster readout time and 10% lower read noise compared to performance previously evaluated without these techniques.

Lin, Kenneth W. (ORCID:0000000189672281)↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

Ultrafast Dynamics of Molecules on Surfaces Studied with Time-Resolved XUV Photoelectron Spectroscopy (Final Report)

In this project we set out to make technical advances in time-resolved photoemission from surfaces and study molecule-surface charge transfer processes. Combining a novel light source developed at Stony Brook with a new type of time-of-flight photoemission electron microscope (TOF k-mic) developed in Mainz, Germany, we achieved the former goal. Our light source, based on cavity-enhanced high harmonic generation at 61 MHz repetition rate, enables ultrafast time-resolved photoemission experiments to be conducted with orders of magnitude higher photocurrents than otherwise possible. Critically, this provides the high dynamic range necessary to study perturbatively excited samples, such that one can study the intrinsic dynamics of electrons and holes as they would occur in a device. Combining our light source with the TOF k-mic, we’ve achieved an overall improvement in data rate of time- and angle-resolved photoemission (tr-ARPES) of approximately four orders of magnitude over the previous state-of-the-art using kHz-repetition rate sources and conventional hemispherical electron analyzers. This new instrument is now being used in experiments on 2D materials and organic semiconductors.

74 ATOMIC AND MOLECULAR PHYSICS↗

NLR HPC Eagle Node Power Data

Power time series captured from all Eagle nodes using iLO (Integrated Lights Out) The Eagle HPC operated at NLR from 2019 through 2024. Eagle was a 2,000-node, 8-petaflop system. This dataset is a comprehensive time series of instantaneous snapshots of power usage at 1 minute intervals from all nodes at the node level. Data provided in compressed Hive dataset/Parquet format. iLO Power Time Series Fields ts: Timestamp dv: Device / Node - Rack and Unit - r103u17 == r(ack)103u(nit)17 vl: Value - Value in watts (instantaneous value at sampling time) day month year

97 MATHEMATICS AND COMPUTING↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Thermal Transport and Mechanical Stress Mapping of a Compression Bonded GaN/Diamond Interface for Vertical Power Devices

Bonding diamond to the back side of gallium nitride (GaN) electronics has been shown to improve thermal management in lateral devices; however, engineering challenges remain with the bonding process and characterizing the bond quality for vertical device architectures. Here, in this study, integration of these two materials is achieved by room-temperature compression bonding centimeter-scale GaN and a diamond die via an intermetallic bonding layer of Ti/Au. Recent attempts at GaN/diamond bonding have utilized a modified surface activation bonding (SAB) method, which requires Ar fast atom bombardment immediately followed by bonding within the same tool under ultrahigh vacuum (UHV) conditions. The method presented here does not require a dedicated SAB tool yet still achieves bonding via a room-temperature metal–metal compression process. Imaging of the buried interface and the total bonding area is achieved via transmission electron microscopy (TEM) and confocal acoustic scanning microscopy (C-SAM), respectively. The thermal transport quality of the bond is extracted from spatially resolved frequency-domain thermoreflectance (FDTR) with the bonded areas boasting a thermal boundary conductance of >100 MW/m 2 ·K. Additionally, Raman maps of GaN near the GaN–diamond interface reveal a low level of compressive stress, <80 MPa, in well-bonded regions. FDTR and Raman were coutilized to map these buried interfaces and revealed some poor thermally bonded areas bordered by high-stress regions, highlighting the importance of spatial sampling for a complete picture of bond quality. Overall, this work demonstrates a novel method for thermal management in vertical GaN devices that maintains low intrinsic stresses while boasting high thermal boundary conductances.

Raman↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗