Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

High-harmonic generation from artificially stacked 2D crystals

Here, we report a coherent layer-by-layer build-up of high-order harmonic generation (HHG) in artificially stacked transition metal dichalcogenides (TMDC) crystals in their various stacking configurations. In the experiments, millimeter-sized single crystalline monolayers are synthesized using the gold foil-exfoliation method, followed by artificially stacking on a transparent substrate. High-order harmonics up to the 19th order are generated by the interaction with a mid-infrared (MIR) driving laser. We find that the generation is sensitive to both the number of layers and their relative orientation. For AAAA stacking configuration, both odd- and even-orders exhibit a quadratic increase in intensity as a function of the number of layers, which is a signature of constructive interference of high-harmonic emission from successive layers. Particularly, we observe some deviations from this scaling at photon energies above the bandgap, which is explained by self-absorption effects. For AB and ABAB stacking, even-order harmonics remain below the detection level, consistent with the presence of inversion symmetry. Our study confirms our capability of producing nonperturbative high-order harmonics from stacked layered materials subjected to intense MIR fields without damaging samples. Our results have implications for optimizing solid-state HHG sources at the nanoscale and developing high-harmonics as an ultrafast probe of artificially stacked layered materials. Because the HHG process is a strong-field driven process, it has the potential to probe high-momentum and energy states in the bandstructure combined with atomic-scale sensitivity in real space, making it an attractive probe of novel material structures such as the Moiré pattern.

2D materials↗

Asymmetries in ionization of atomic superposition states by ultrashort laser pulses

Abstract Progress in ultrafast science allows for probing quantum superposition states with ultrashort laser pulses in the new regime where several linear and nonlinear ionization pathways compete. Interferences of pathways can be observed in the photoelectron angular distribution and in the past they have been analyzed for atoms and molecules in a single quantum state via anisotropy and asymmetry parameters. Those conventional parameters, however, do not provide comprehensive tools for probing superposition states in the emerging research area of bright and ultrashort light sources, such as free-electron lasers and high-order harmonic generation. We propose a new set of generalized asymmetry parameters which are sensitive to interference effects in the photoionization and the interplay of competing pathways as the laser pulse duration is shortened and the laser intensity is increased. The relevance of the parameters is demonstrated using results of state-of-the-art numerical solutions of the time-dependent Schrödinger equation for ionization of helium atom and neon atom.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous on-chip generation of violet, blue, cyan, green, yellow, orange, and red light from an octave-spanning infrared frequency comb

An integrated, multi-spectral visible-light source could significantly benefit technologies such as displays, medical imaging, spectroscopy, visible-light communications, and astrophysics. However, despite recent advances in chip-scale visible lasers, simultaneously generating light of all colors in a single chip has been challenging. Existing solutions are either not suitable for full chip-scale integration, or are fundamentally difficult to scale. Here we demonstrate the simultaneous on-chip generation of infrared, red, orange, yellow, green, cyan, blue, and violet light. Leveraging the low loss, low dispersion, and high density of modes of an adiabatic multimode silicon nitride (SiN) microresonator, we use a single infrared pump of moderate power (~130 mW) to produce an octave-spanning infrared frequency comb that is then converted to different portions of the visible spectrum. We measure non-mode-locked combs and soliton steps corresponding to mode-locked states, making our comb generator suitable for applications that demand either low or high coherence. Since the required pump power is compatible with high-power lasers demonstrated in the same SiN platform, our multi-octave light generator can be fully integrated in a chip-scale form factor. We envision that such a light source will be a catalyst for the development and deployment of miniaturized multi-spectral technologies for quantum systems, medical imaging, displays, and spectroscopy.

47 OTHER INSTRUMENTATION↗

Laser Wavelength Shift from Splitters and Switches

The Detonation Science and Technology Group (Q-6) operates several photon Doppler velocimetry (PDV) systems as a diagnostic tool for measuring velocities in the 1–10 km/s range during high explosive (HE) detonation experiments. Q-6 uses “heterodyne” PDV systems that are produced by Traverse Solutions and Instrumentation, LLC (TS&I). These heterodyne systems combine wavelength (WL) tunable source and “reference” lasers with a WL offset of 10–100 pm from each other. Properly setting the source and reference WLs for an experiment can be critical for collecting the desired experimental data. The tunable lasers report WL readings in their control software, but these readings are based on a lookup table from a temperature reading and are not able to be calibrated. Therefore, recent test fire programs that require PDV as a diagnostic have also implemented requirements for monitoring the WL of the tunable lasers using a precision WL meter. To monitor the WL of several PDV lasers without disconnecting any patch fibers form the experimental setup, Q-6 developed a system splitters with a coupling ratio (%) of 99:1 and an optical switch with the switch output going to a single WL meter. A brief experiment was developed to determine if the splitters and/or switch introduced any WL bias into the readings. The purpose of this report is to document the system, the experiment, and its results.

42 ENGINEERING↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronic Population Transfer via Impulsive Stimulated X-Ray Raman Scattering with Attosecond Soft-X-Ray Pulses

Free electron lasers provide a source of X-ray pulses short enough and intense enough to drive nonlinearities in molecular systems. Impulsive interactions driven by these X-ray pulses provide a way to create and probe valence electron motions with high temporal and spatial resolution. Observing these electronic motions is crucial to understand the role of electronic coherence in chemical processes. A simple nonlinear technique for probing electronic motion, impulsive stimulated X-ray Raman scattering (ISXRS), involves a single impulsive interaction to produce a coherent superposition of electronic states. In this work, we demonstrate electronic population transfer via ISXRS using broad bandwidth (5.5 eV full width at half maximum) attosecond X-ray pulses produced by the Linac Coherent Light Source (LCLS). The impulsive excitation is resonantly enhanced by the oxygen 1s → 2π* resonance of nitric oxide (NO), and excited state neutral molecules are probed with a time-delayed UV laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

Bio‐Inspired Cascade Photocatalysis on Fe Single‐Atom Carbon Nitride Upcycles Plastic Wastes for Effective Acetic Acid Production

Plastic imposes a critical threat to the environment, ecosystems, and human health because of the low utilization efficiency of plastics. Here, we demonstrate a sustainable, highly efficient cascade photocatalysis for upcycle plastics to value-added acetic acid using Fe single-atom catalysts (Fe@C 3 N 4 SAC) at ambient conditions. Inspired by Phanerochaete chrysosporium microbial, the defective Fe@C 3 N 4 SAC acts as a bifunctional cascade photocatalyst for both Fenton-like and CO 2 reduction reactions. During the reaction, hydroxyl radicals (*OH) form and subsequently oxidize plastics into CO 2 intermediates. These CO 2 intermediates are then photo-reduced to CH 3 COOH on the same catalyst via cascade photocatalysis. The mechanism is confirmed by in situ multimodal microscopy and spectroscopies, with density functional theory calculations. A state-of-art CH 3 COOH yield of 63.8 mg h −1 gcat −1 from PVC, 12.7 mg h −1 gcat −1 from PE, 5.4 mg h −1 gcat −1 from PET, and 5.3 mg h −1 gcat −1 from PP are directly obtained under AM1.5G solar irradiation and further validated under real sunlight (≈0.6 sun), achieving 5.6 mg h −1 gcat −1 from PET, using low-cost Fe@C 3 N 4 SAC in a sealed reactor by enhancing the photon transport and utilization efficiency. The techno-economic analysis shows it is promising to practically mitigate plastic based on broader social welfare assessments.

cascade photocatalysis↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

Supercontinuum generation in oxide and semiconductor materials (InP, Si, GaN, GaAs, PbMoO 4 , YVO 4 , ZGP, TiO 2 , diamond) pumped by radiation of the Cr:ZnS fs-MOPA system

Ultrashort light sources in the middle-infrared range are highly beneficial for applications such as gas molecular spectroscopy, remote sensing, atmospheric science, medical treatments, and light–matter interaction studies. Ultrafast lasers utilizing chromium-doped ZnS/Se (Cr:ZnS/Se) have proven to be robust and stable solutions within this spectral region. Nonlinear spectral broadening is fundamentally important, as it pushes the pulse duration limits imposed by the bandwidth of laser media. In this study, we demonstrate the spectral broadening and supercontinuum generation in several bulk materials, including InP, Si, GaN, GaAs, PbMoO 4 , YVO 4 , diamond, and TiO 2 , using pump radiation with up to 4 W average power centered at 2.35 µm from a Cr:ZnS femtosecond MOPA system. Some of the investigated materials have excellent potential as effective media for middle-infrared supercontinuum generation, demonstrating the feasibility of developing a single-cycle pulse middle-infrared laser system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging Wavepackets in Real-Space & Disentangling Ultrafast Solvation Dynamics with High-Energy Ultrafast X-ray Scattering

The microscopic information of solute and solute-solvent motions can be measured using ultrafast diffuse x-ray scattering, and compared to molecular dynamics simulations, as demonstrated in studies of solvated molecular systems done in X-ray free-electron lasers. However, for the typical photon energies used in these experiments, the photon momentum transfer range was limited to lower Q values where the signals arising from different parts of the studied system overlap significantly. Recently, this limitation was greatly alleviated by extending the photon energy at the Linac Coherent Light-Source (LCLS), significantly increasing the accessible momentum transfer range. This improvement is transformative for ultrafast diffuse x-ray scattering measurements, enabling for the first time to disentangle the solute scattering difference signal, that persists to higher Q values, from the bulk solvent and solute-solvent cross-terms difference signals. In addition, it enhances the prediction ability of modeling and simulation methods such as the hybrid QM/MM approach. The extended Q range also opens the way to resolve in real-space details regarding coherent wavepackets motions beyond their center-of-mass positions. Here, we present the first results on high-energy (18keV) diffuse x-ray scattering in solution, demonstrating high fidelity time-resolved scattering and analysis of the photoexcited model photocatalysts PtPOP ([Pt2(POP)4]4-), and IrDimen ([Ir2(dimen)4]2+) in several solvents. These complexes provide ideal systems for demonstrating the ability of high-Q ultrafast scattering and QM/MM simulations to decompose ultrafast solvation dynamics into specific changes in the solute-solvent pair distribution function with a particular focus on how electronically excited states change the interaction between the solvent and photo-catalytically active metal sites. We introduce an approach to further utilize the high-energy capability and demonstrate a single-shot ultra-wide-angle X-ray Scattering modality using two perpendicular detectors, spanning a scattering angle range of more than 100 degrees, allowing to extend the accessible momentum transfer range up to Q~14 Å-1. We develop a model-free method to invert the x-ray scattering signals and enable the recovery of multiple pair-density motions that happen simultaneously, allowing us to directly measure in real-space nuclear wavepacket motions. . [1] Natan, Adi. "Real-Space Inversion and Super-Resolution of Ultrafast X-ray Scattering using Natural Scattering Kernels." arXiv preprint arXiv:2107.05576 (2021)

Natan, Adi↗

Graviton detection and the quantization of gravity

We revisit a question asked by Dyson: “Is a graviton detectable?” We demonstrate that in both Dyson’s original sense and in a more modern measurement-theoretic sense, it is possible to construct a detector sensitive to single gravitons, and in fact a variety of existing and near-term gravitational wave detectors can achieve this. However, while such a signal would be consistent with the quantization of the gravitational field, we draw on results from quantum optics to show how the same signal could just as well be explained via classical gravitational waves. We outline the kind of measurements that would be needed to demonstrate quantization of gravitational radiation and explain why these are substantially more difficult than simply counting graviton clicks or observing gravitational noise in an interferometer, and likely impossible to perform in practice. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrostatic Superlattices Beyond 1:1 Stoichiometry

ABSTRACT Exotic nanoparticle superstructures can be accessed by harnessing nanoparticle softness and charge regulation, features often viewed as obstacles to structural control. Here, we show that regulated charge mismatch in polymer‐grafted nanoparticles enables the assembly of high‐stoichiometry cubic superlattices. By co‐tuning grafting density, particle size, and bulk composition, we realize ionic‐lattice analogues, such as and , as well as single‐component and superlattices without atomic counterparts. The superlattice has recently been identified theoretically as a photonic band‐gap lattice. These phases emerge from a 1:1 “parent” lattice when local charge neutrality cannot be satisfied, driving either progressive interstitial filling or reorganization into a larger basis. For instance, the systematic occupation of ZnS tetrahedral sites yields , while ligand‐swapping symmetry breaking converts CsCl into . Upon heating, the assemblies exhibit reversible lattice contraction and pronounced negative thermal expansion. Furthermore, the energetic penalty for defects increases with nanoparticle size, facilitating the scalable production of high‐quality, open superlattices for photonic applications.

36 MATERIALS SCIENCE↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

Diffuse scattering from correlated electron systems

The role of inhomegeneity in determining the properties of correlated electron systems is poorly understood because of the dearth of structural probes of disorder at the nanoscale. Advances in both neutron and x-ray scattering instrumentation now allow comprehensive measurements of diffuse scattering in single crystals over large volumes of reciprocal space, enabling structural correlations to be characterized over a range of length scales from 5 to 200 angstroms or more. When combined with new analysis tools, such as three-dimensional difference pair-distribution functions, these advanced capabilities have produced fresh insights into the interplay of structural fluctuations and electronic properties in a broad range of correlated electron materials. This review describes recent investigations that have demonstrated the importance of understanding structural inhomogeneity pertaining to phenomena as diverse as superconductivity, charge density wave modulations, metal-insulator transitions, and multipolar interactions.

36 MATERIALS SCIENCE↗