Search NASA⌕ Search

SEARCH · Search NASA

Results for “CMOS technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Multifunctional Logic Gate Controlled by Temperature

A complementary metal oxide/semiconductor (CMOS) electronic circuit has been designed to function as a NAND gate at a temperature between 0 and 80 deg C and as a NOR gate at temperatures from 120 to 200 C. In the intermediate temperature range of 80 to 120 C, this circuit is expected to perform a function intermediate between NAND and NOR with degraded noise margin. The process of designing the circuit and the planned fabrication and testing of the circuit are parts of demonstration of polymorphic electronics a technological discipline that emphasizes designing the same circuit to perform different analog and/or digital functions under different conditions. In this case, the different conditions are different temperatures.

Stoica, Adrian↗

Direct electron beam patterning of electro-optically active PEDOT:PSS

The optical and electronic tunability of the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has enabled emerging applications as diverse as bioelectronics, flexible electronics, and micro- and nano-photonics. High-resolution spatial patterning of PEDOT:PSS opens up opportunities for novel active devices in a range of fields. However, typical lithographic processes require tedious indirect patterning and dry etch processes, while solution-processing methods such as ink-jet printing have limited spatial resolution. Here, we report a method for direct write nano-patterning of commercially available PEDOT:PSS through electron-beam induced solubility modulation. The written structures are water stable and maintain the conductivity as well as electrochemical and optical properties of PEDOT:PSS, highlighting the broad utility of our method. We demonstrate the potential of our strategy by preparing prototypical nano-wire structures with feature sizes down to 250 nm, an order of magnitude finer than previously reported direct write methods, opening the possibility of writing chip-scale microelectronic and optical devices. We finally use the high-resolution writing capabilities to fabricate electrically-switchable optical diffraction gratings. We show active switching in this archetypal system with >95 % contrast at CMOS-compatible voltages of +2 V and -3 V, offering a route towards highly-miniaturized dynamic optoelectronic devices.

42 ENGINEERING↗

Cryogenic Electronics development for High Energy Physics

In the quest to study the fundamental nature of matterand the universe, High Energy Physics (HEP) experimentsoften operate in extreme conditions that lie well outside thestandard operating range of integrated circuits. Two prominentexamples of such extreme environments are the irradiationlevels experienced at high luminosity colliders, as well asoperation at cryogenic temperatures. Cryogenic electronicsis a broad term that encompasses circuits operating at temperatures below the standard operating limit (-55°C in the caseof military grade electronics), all the way down to millikelvin,as in the case of superconducting circuits. Cryogenic circuitshave a long history and have found applications in abroad spectrum of applications, such as infrared focal planearrays, PET, quantum science. While CMOS circuits have beenreliably operated at deep cryogenic temperatures (<4.2K),this article focuses on applications down to liquid Nitrogen(77K), and provides an overview on the design considerations,benefits, and unique challenges pertaining to cryogenic CMOSICs for large HEP experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A secure measurement unit for an inspection system used in nuclear arms-control verification

Verification of arms control treaties may require information barriers to protect sensitive data acquired during the verification process. These information barriers are commonly implemented in software, but must store and operate on data that are vulnerable to attack and tampering. Here, we present a new Secure Measurement Unit based on a modified pipeline SAR ADC architecture. The idea is to move the information barrier back into the digitization process so that prohibited data is never created. A prototype 65nm CMOS Secure Measurement Unit (SMU) was tested using U-235, U-238, Co-60, Cs-137 and Am-241 sources. Here, the prototype accurately digitized allowable signals while being immune to side-channel attacks on signals within preset forbidden regions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of imaging methods for use in an array biosensor

An array biosensor has been developed which uses an actively-cooled, charge-coupled device (CCD) imager. In an effort to save money and space, a complementary metal-oxide semiconductor (CMOS) camera and photodiode were tested as replacements for the cooled CCD imager. Different concentrations of CY5 fluorescent dye in glycerol were imaged using the three different detection systems with the same imaging optics. Signal discrimination above noise was compared for each of the three systems.

Evaluation Studies↗

DARPA beyond CMOS RFI

The Lawrence Livermore National Laboratory Center for Micro and Nanotechnology (CMNT) is located on the LLNL campus in Livermore, CA. LLNL employs over 7000 employees with a broad range of science and engineering backgrounds with an administrative structure that encourages multidisciplinary teaming, a key ingredient in our ability to address diverse technical problems. Our CMNT facility houses a 6,400 ft 2 class 100 cleanroom (class 10 capable) with an additional 1,000 ft 2 Class 1000 space, and 6000 ft 2 of other laboratories. Most equipment can accommodate 6” wafers, although some is limited to 4”. The CMNT is a multi-user, multi-programmatic facility that offers a broad set of instruments for microfabrication to invent, develop, and apply microscale and nanoscale technologies to support national security missions in Stockpile Stewardship, Homeland Security, Directed Energy, Nonproliferation, biomedical research, and more. The research and capabilities of the Center cover materials, devices, instruments, and systems that require microfabricated components, including microelectromechanical systems (MEMS), electronics, photonics, micro- and nanostructures, bio-implantable devices, and micro- and nanoactuators.

42 ENGINEERING↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of a Point-Like Transmission Target for Reducing Computed Tomography Imaging Artifacts

In this study, we address the challenge of enhancing image quality and spatial resolution in computed tomography (CT) imaging by introducing simulation and fabrication of high aspect ratio, point-like transmission targets. Utilizing advanced electroplating techniques, traditionally employed in the fabrication of Through Substrate Via (TSV) interconnects for CMOS circuitry, we successfully embed copper targets within silicon substrates. This method allows us to create high-aspect-ratio features specifically designed for X-ray transmission targets, resulting in micro targets that exhibit a volume increase compared to conventional evaporated surface targets. Furthermore, we present simulation results of the X-ray spectrum generated by these targets, demonstrating their potential to significantly improve both image quality and spatial resolution in CT applications. Our findings suggest that leveraging advanced fabrication techniques can open new avenues for the development of enhanced imaging technologies in medical diagnostics and beyond.

47 OTHER INSTRUMENTATION↗

NSC 800, 8-bit CMOS microprocessor

The NSC 800 is an 8-bit CMOS microprocessor manufactured by National Semiconductor Corp., Santa Clara, California. The 8-bit microprocessor chip with 40-pad pin-terminals has eight address buffers (A8-A15), eight data address -- I/O buffers (AD(sub 0)-AD(sub 7)), six interrupt controls and sixteen timing controls with a chip clock generator and an 8-bit dynamic RAM refresh circuit. The 22 internal registers have the capability of addressing 64K bytes of memory and 256 I/O devices. The chip is fabricated on N-type (100) silicon using self-aligned polysilicon gates and local oxidation process technology. The chip interconnect consists of four levels: Aluminum, Polysi 2, Polysi 1, and P(+) and N(+) diffusions. The four levels, except for contact interface, are isolated by interlevel oxide. The chip is packaged in a 40-pin dual-in-line (DIP), side brazed, hermetically sealed, ceramic package with a metal lid. The operating voltage for the device is 5 V. It is available in three operating temperature ranges: 0 to +70 C, -40 to +85 C, and -55 to +125 C. Two devices were submitted for product evaluation by F. Stott, MTS, JPL Microprocessor Specialist. The devices were pencil-marked and photographed for identification.

Suszko, S. F.↗

An optical processor for object recognition and tracking

The design and development of a miniaturized optical processor that performs real time image correlation are described. The optical correlator utilizes the Vander Lugt matched spatial filter technique. The correlation output, a focused beam of light, is imaged onto a CMOS photodetector array. In addition to performing target recognition, the device also tracks the target. The hardware, composed of optical and electro-optical components, occupies only 590 cu cm of volume. A complete correlator system would also include an input imaging lens. This optical processing system is compact, rugged, requires only 3.5 watts of operating power, and weighs less than 3 kg. It represents a major achievement in miniaturizing optical processors. When considered as a special-purpose processing unit, it is an attractive alternative to conventional digital image recognition processing. It is conceivable that the combined technology of both optical and ditital processing could result in a very advanced robot vision system.

Sloan, J.↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

focal plane arrays (FPAs)↗

Development of UItra-Low Temperature Motor Controllers: Ultra Low Temperatures Evaluation and Characterization of Semiconductor Technologies For The Next Generation Space Telescope

Electronics designed for low temperature operation will result in more efficient systems than room temperature. This improvement is a result of better electronic, electrical, and thermal properties of materials at low temperatures. In particular, the performance of certain semiconductor devices improves with decreasing temperature down to ultra-low temperature (-273 'C). The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical components and systems suitable for applications in deep space missions. Research is being conducted on devices and systems for use down to liquid helium temperatures (-273 'C). Some of the components that are being characterized include semiconductor switching devices, resistors, magnetics, and capacitors. The work performed this summer has focused on the evaluation of silicon-, silicon-germanium- and gallium-Arsenide-based (GaAs) bipolar, MOS and CMOS discrete components and integrated circuits (ICs), from room temperature (23 'C) down to ultra low temperatures (-263 'C).

Elbuluk, Malik E.↗

Human Factors in Training - Space Medicine Proficiency Training

The early Constellation space missions are expected to have medical capabilities very similar to those currently on the Space Shuttle and International Space Station (ISS). For Crew Exploration Vehicle (CEV) missions to ISS, medical equipment will be located on ISS, and carried into CEV in the event of an emergency. Flight Surgeons (FS) on the ground in Mission Control will be expected to direct the Crew Medical Officer (CMO) during medical situations. If there is a loss of signal and the crew is unable to communicate with the ground, a CMO would be expected to carry out medical procedures without the aid of a FS. In these situations, performance support tools can be used to reduce errors and time to perform emergency medical tasks. Work on medical training has been conducted in collaboration with the Medical Training Group at the Space Life Sciences Directorate and with Wyle Lab which provides medical training to crew members, Biomedical Engineers (BMEs), and to flight surgeons under the JSC Space Life Sciences Directorate s Bioastronautics contract. The space medical training work is part of the Human Factors in Training Directed Research Project (DRP) of the Space Human Factors Engineering (SHFE) Project under the Space Human Factors and Habitability (SHFH) Element of the Human Research Program (HRP). Human factors researchers at Johnson Space Center have recently investigated medical performance support tools for CMOs on-orbit, and FSs on the ground, and researchers at the Ames Research Center performed a literature review on medical errors. The work proposed for FY10 continues to build on this strong collaboration with the Space Medical Training Group and previous research. This abstract focuses on two areas of work involving Performance Support Tools for Space Medical Operations. One area of research building on activities from FY08, involved the feasibility of just-in-time (JIT) training techniques and concepts for real-time medical procedures. In Phase 1, preliminary feasibility data was gathered for two types of prototype display technologies: a hand-held PDA, and a Head Mounted Display (HMD). The PDA and HMD were compared while performing a simulated medical procedure using ISS flight-like medical equipment. Based on the outcome of Phase 1, including data on user preferences, further testing was completed using the PDA only. Phase 2 explored a wrist-mounted PDA, and compared it to a paper cue card. For each phase, time to complete procedures, errors, and user satisfaction ratings were captured.

Connell, Erin↗

A review of quantum imaging methods and enabling technologies

The field of quantum imaging has recently seen an explosion of new methods and techniques. At the heart of most quantum imaging approaches are three enabling technologies: the source of the quantum light, the detectors that turn sensing into imaging, and the method by which the quantum nature of light is leveraged to improve the desired measurement. This review addresses the dominant and emerging technologies in each of these components as well as details concerning the implementations of various quantum imaging methods.

36 MATERIALS SCIENCE↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas puff imaging on the TCV tokamak

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗