At least 343 records · Page 19

Influence of the air-cooled supercritical carbon dioxide recompression cycle design-point on molten salt power tower techno-economic performance

Here, this paper investigates the techno-economic performance of a molten salt power tower integrated with an air-cooled supercritical carbon dioxide recompression cycle. Prior research into the cycle design point showed trade-offs between efficiency, cost, and temperature difference across the heat input, resulting in trade-offs between the design-point generation of the molten salt power tower system and the cost of sensible-heat thermal energy storage. Prior research into cycle off-design showed that colder ambient temperature designs have higher efficiencies on cold days but lower efficiency and capacity degradation on hot days. We present a framework to evaluate how cycle design, cost, and corresponding off-design performance affect the techno-economic performance of the molten salt power tower system. We use a steady-state off-design cycle model assuming fixed shaft speeds, inventory control, and air-cooler fan power control and integrate the cycle model with the molten salt power tower model from the National Renewable Energy Laboratory's System Advisor Model. First, we present a surrogate model that uses a heuristic approach to correct the interpolation when the cycle reaches capacity limitations at ambient temperatures hotter than design. Next, we evaluate how the recompression cycle design-point ambient temperature, air-cooler approach temperature, air-cooler fan power, and recuperator conductance influence cycle and system design metrics. Finally, we complete annual simulations using an hourly "duck curve" pricing schedule and present annual performance metrics to evaluate the cumulative effects of the cycle design parameters and corresponding off-design performance on molten salt power tower techno-economics.

14 SOLAR ENERGY↗

Energy Efficient Large-Scale Storage of Liquid Hydrogen

The world’s largest liquid hydrogen storage tanks were constructed in the mid-1960sat the NASA Kennedy Space Center. These two vacuum-jacketed, perlite powder insulated tanks, still in service today, have 3,200 m3 of useable capacity. In 2018, construction began on an additional storage tank at Launch Complex 39B. This new tank will give an additional storage capacity of 4,700 m3 for a total on-site storage capacity of roughly 8,000 m3. NASA’s new Space Launch System (SLS) heavy lift rocket for the Artemis program includes an LH2tank that makes up the bulk of the vehicle, holding 2,033 m3 of LH2 in its 8.4-m diameter by40-m height. The new storage tank includes two new energy-efficient technologies: a glass bubbles insulation system in lieu of perlite, and an Integrated Refrigeration and Storage (IRAS)heat exchanger for controlled storage capability. The evacuated glass bubbles insulation system is based on the prior two decades of research to prove the thermal performance benefits as well as the mechanical and vacuum integrity; and has been shown to reduce LH2 boiloff by 46%versus perlite in field demonstrations. The IRAS capability is centered on a heat exchanger system that is built within the inner vessel to reject heat from the bulk liquid through the future implementation of an external helium refrigerator. Controlled storage via IRAS, when fully implemented, will provide full control of the ullage pressure, zero boiloff, and even production of densified LH2 pending its adoption on future launch vehicles. The design basics are described along with main construction and testing processes involved. The key features of the new technology items and implications on simplified operations and long-term energy savings are addressed

cryogenics↗

Pumped-Thermal Electricity Storage Based on Brayton Cycles

Pumped-thermal electricity storage (PTES) based on a reversible (Joule-)Brayton cycle is a promising grid-scale energy storage technology, whose working principle is to store electricity in the form of high-grade thermal energy. This chapter provides an overview of the inner workings, operating principle and current development status of the many PTES variants, as proposed to date in the scientific literature or by manufacturers. The potential and competitiveness of the various candidate designs is quantified by - and discussed thanks to the definition of - specific techno-economic indicators. Investment cost and thermodynamic performance estimates are reported and used to assess the value of this technology as a potential large-scale, long-duration and long-lifetime energy storage option with unique sector-coupling features and low geographical constraints.

electricity storage↗

Estimated performance and future potential of solar dynamic and photovoltaic power systems for selected LEO and HEO missions

Solar photovoltaic and thermal dynamic power systems for application to selected low-earth-orbit (LEO) and high-earth-orbit (HEO) missions are characterized in the regime 7 to 35 kWe. Input parameters to the characterization are varied to correspond to anticipated introduction of improved or new technologies. A comparative assessment is made of the two power system types for emerging technologies in cells and arrays, energy storage, optical surfaces, heat engines, thermal energy storage and thermal management. The assessment is made to common ground rules and assumptions. The four missions (Space Station, sun-synchronous, Van Allen belt, and GEO) are representative of the anticipated range of multikilowatt earth-orbit missions. The results give the expected performance, mass and drag of multikilowatt earth-orbiting solar power systems and show how the overall system figure of merit will improve as new component technologies are incorporated.

Bents, David J.↗

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics↗

Investigation of storage system designs and techniques for optimizing energy conservation in integrated utility systems. Volume 1: (Executive summary)

Integrated Utility Systems (IUS) have been suggested as a means of reducing the cost and conserving the nonrenewable energy resources required to supply utility services (energy, water, and waste disposal) to developments of limited size. The potential for further improving the performance and reducing the cost of IUS installations through the use of energy storage devices is examined and the results are summarized. Candidate energy storage concepts in the general areas of thermal, inertial, superconducting magnetic, electrochemical, chemical, and compressed air energy storage are assessed and the storage of thermal energy as the sensible heat of water is selected as the primary candidate for near term application to IUS.

Source record↗

Addressing Data Center Cooling Needs through the Use of Subsurface Thermal Energy Storage Systems

This study aims to evaluate the feasibility of addressing the cooling needs for information technology (IT) equipment in data centers by using reservoir thermal energy storage (RTES) to provide reliable and sustainable low-temperature fluid. This project focuses on the technical viability of operating such a system in Houston, Texas, which is a representative location for crypto mining data centers. An analysis has been performed to investigate the technical feasibility with climate data for Houston. Results show that data centers on the scale of 30 MW, and operating at a temperature of 27 degrees C, can be reliably cooled by a combined RTES and dry coolers setup. A techno-economic analysis will be performed and energy/water saving benefits will be quantified in the future. In addition, the study will be extended to other representative data center locations with different climates and geographical locations.

cooling↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Solar White Thermal Coating for Cryogenic Propulsion Systems

NASA is currently conducting research into the potential of storing cryogenic fluid in low Earth orbit (LEO). Having cryogenic propellant readily available for high-performance propulsion systems can be very beneficial for deep space missions in the near future. One of the key challenges to storing cryogenic fluid in LEO is minimizing boil-off. To address the challenge, NASA is evaluating new concepts in thermal insulation. One recent experimental study evaluated the feasibility of using Yttrium Oxide (Y2O3), formed into tiles or spray coating that can potentially be used as a thermal coating for cryogenic propellant storage applications in deep space. Due to its temperature and wavelength dependent optical properties, this “solar white” material can reflect a vast majority of the Sun’s radiative energy while having a very high infrared emissivity for rejecting heat to deep space. As a part of the material development and proof of concept testing, multiple tests have been run at KSC and GRC to demonstrate the performance of the material. At GRC, the tests were run using the Deep Space Solar Simulator (DS3) which contains a thermal vacuum chamber in which the solar white sample was exposed to a deep space environment (< 10 K, optically dense walls) while under full illumination via solar lamp. In order to improve the use of the test results and apply them to spacecraft, there is a need to be able to model the material properties within NASA’s standard thermal modeling tools. As such, it was set out to verify a thermal model of one of the experiments using Thermal Desktop with Sinda. The thermal model of the DS3 test setup includes the solar white sample along with a solar lamp simulator capable of outputting heat at varying wavelengths. The model was developed in order to validate the test results and also to help predict results that will be obtained in future tests. This paper will review the modeling methods and thermal analysis results for various test cases that were run within the DS3 facility.

Cryogenic↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An HPC-Based Hydrothermal Finite Element Simulator for Modeling Underground Response to Community-Scale Geothermal Energy Production

Geothermal heat, as renewable energy, shows great advantage with respect to its environmental impact due to its significantly lower CO2 emissions than conventional fossil fuel. Open and closed-loop geothermal heat pumps, which utilize shallow geothermal systems, are an efficient technology for cooling and heating buildings, especially in urban areas. Integrated use of geothermal energy technologies for district heating, cooling, and thermal energy storage can be applied to optimize the subsurface for communities to provide them with multiple sustainable energy and community resilience benefits. The utilization of the subsurface resources may lead to a variation in the underground environment, which might further impact local environmental conditions. However, very few simulators can handle such a highly complex set of coupled computations on a regional or city scale. We have developed high-performance computing (HPC) based hydrothermal finite element (FE) simulator that can simulate the subsurface and its hydrothermal conditions at a scale of tens of km. The HPC simulator enables us to investigate the subsurface thermal and hydrologic response to the built underground environment (such as basements and subways) at the community scale. In this study, a coupled hydrothermal simulator is developed based on the open-source finite element library deal.II. The HPC simulator was validated by comparing the results of a benchmark case study against COMSOL Multiphysics, in which Aquifer Thermal Energy Storage (ATES) is modeled and a process of heat injection into ATES is simulated. The use of an energy pile system at the Treasure Island redevelopment site (San Francisco, CA, USA) was selected as a case study to demonstrate the HPC capability of the developed simulator. The simulator is capable of modeling multiple city-scale geothermal scenarios in a reasonable amount of time.

Sun, Xiang↗

Dual-function lignin monomers enable high-performance graphene electrodes via interface confinement and proton transfer enhancement

Graphene oxide (GO)-based energy storage faces dual bottlenecks: unsustainable reduction methods and sluggish proton transfer kinetics. Here, we introduce a groundbreaking green strategy using lignin-derived vanillyl alcohol (VA) as a dual-function monomer to simultaneously address these challenges. By thermally annealing GO/VA films at mild temperatures (<100 °C), VA triggers an interface-confined reduction of GO while self-polymerizing into redox-active oligomers (P-VA) that intercalate between graphene layers. This dual role-reducing agent and proton highway enables a 3D conductive network with minimized graphene restacking, abundant redox sites, and rapid H + transport pathways. Density Functional Theory (DFT) reveals how P-VA optimizes proton dynamics, while the resulting rGO-P-VA4-T90 electrode achieves a record volumetric capacitance of 311.1F/cm 3 (777.8F/cm 2 ) and retains 87.8 % capacity after 10,000 cycles. Flexible solid-state supercapacitors deliver 94.2 μWh/cm 2 energy density at 63.8 μW/cm 2 , rivaling state-of-the-art devices. Furthermore, this work redefines sustainable graphene engineering, merging biomass valorization with high-performance energy storage in a scalable, eco-friendly paradigm.

Graphene oxide reduction↗

Chapter 4: Vibrational Spectroscopy for Batteries

Dr. Sang-Don Han and Dr. Bertrand Tremolet de Villers describe infrared (IR) and Raman spectroscopy studies. Not only are the fundamental principles and measurement methods or FTIR and Raman presented, but also in situ spectroscopic analysis during battery cycling. The advantage of the in situ method is the additional insight into the chemical, thermal, and electrical mechanisms underlying the battery performance that are largely inaccessible with traditional ex situ measurements. The future perspectives on the continuing evolution of IR spectroscopy in electrochemical energy storage research are also presented.

battery↗

Development of a thermal storage module using modified anhydrous sodium hydroxide

The laboratory scale testing of a modified anhydrous NaOH latent heat storage concept for small solar thermal power systems such as total energy systems utilizing organic Rankine systems is discussed. A diagnostic test on the thermal energy storage module and an investigation of alternative heat transfer fluids and heat exchange concepts are specifically addressed. A previously developed computer simulation model is modified to predict the performance of the module in a solar total energy system environment. In addition, the computer model is expanded to investigate parametrically the incorporation of a second heat exchange inside the module which will vaporize and superheat the Rankine cycle power fluid.

Rice, R. E.↗

Extended development of a sodium hydroxide thermal energy storage module

The post-test evaluation of a single heat exchanger sodium hydroxide thermal energy storage module for use in solar electric generation is reported. Chemical analyses of the storage medium used in the experimental model are presented. The experimental verification of the module performance using an alternate heat transfer fluid, Caloria HT-43, is described. Based on these results, a design analysis of a dual heat exchanger concept within the storage module is presented. A computer model and a reference design for the dual system (storage working fluid/power cycle working fluid) were completed. The dual system is estimated to have a capital cost of approximately one half that of the single heat exchanger concept.

Rice, R. E.↗

High temperature electrolyzer/fuel cell power cycle: Preliminary design considerations

A model of a high temperature electrolyzer/fuel cell, hydrogen/oxygen, thermally regenerative power cycle is developed and used to simulate system performance for varying system parameters. Initial estimates of system efficiency, weight, and volume are provided for a one KWe module assuming specific electrolyzer and fuel cell characteristics, both current and future. Specific interest is placed on examining the system responses to changes in device voltage versus current density operating curves, and the associated optimum operating ranges. The performance of a solar-powered, space based system in low earth orbit is examined in terms of the light-dark periods requiring storage. The storage design tradeoffs between thermal energy, electrical energy, and hydrogen/oxygen mass storage are examined. The current technology module is based on the 1000 C solid oxide electrolyzer cell and the alkaline fuel cell. The Future Technology system examines benefits involved with developing a 1800K electrolyzer operating with an advanced fuel cell.

Morehouse, Jeffrey H.↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗