Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electromagnetic pulse (EMP)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Computational prediction of dielectric breakdown strength of a transformer paper in oil with uncertainty quantification

The determination of the dielectric breakdown strengths of microstructurally heterogeneous materials has been a primarily experimental endeavor. We report the development of a microstructure-level model for computationally predicting the breakdown strength and analyzing the interactions between electromagnetic pulses (EMP) and the constituents in a composite of cellulose-based paper and mineral oil found in electrical transformers. The model allows explicit simulation of the material breakdown process by tracking the transition of dielectric constituents from non-conductive to conductive states. The focus is on the electric fields induced in the materials and the overall conditions for dielectric breakdown (defined as the onset of avalanche) caused by the electric field induced in the composite. Responses to three distinct pulse shapes, i.e., Steep Front (SF), Lightning (L), and AC with spectra spanning 60–9 × 105 Hz are considered. It is found that the breakdown strength of the material is significantly affected by microstructure heterogeneities, the spatial variations of the constituent properties, and the pulse shapes. A probabilistic characterization of the breakdown strength is computationally obtained and compared with experimental measurements. Although one particular material is analyzed, the model and approach are applicable to other heterogeneous materials as well.

breakdowns↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

High-Altitude Burst Observed at Large Ground Ranges

The rise times computed by the author’s three-dimensional geomagnetic electromagnetic pulse (EMP) code MACSYNC for a high-altitude nuclear burst increase from a fraction of a shake under the burst to tens of shakes at a 1,000 km ground range (one shake equals 10 nanoseconds). Computations for similar geometries with the frequently used one-dimensional spherical EMP codes CHAP and HEMP show similar rise times under the burst, but rise times that are an order-of-magnitude shorter at large ground ranges. This difference is likely due to the inability of these codes to treat the three-dimensional aspect of the slanted EMP incidence on the atmosphere.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Operation Fishbowl

Fishbowl’s primary objective was to generate data on electromagnetic pulses (EMP), the creation and behavior of auroras, and the impact of a high altitude nuclear burst on radio communications. Previous high altitude tests (Teak, Orange, and Yucca) were not instrumented to provide such data, which was deemed critical to countering any Soviet high altitude bursts. The first test of Fishbowl, Starfish Prime, exploded on July 9th with a yield of 1.4 megatons. Standing on Christmas Island, Austin McGuire witnessed the effects of the event.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Industry Requirements for Geomagnetic Disturbance Models

This research project will address the most pressing uncertainties in modeling and measuring the electric power grid effects of geomagnetic disturbances (GMDs) and the E3 portion of nuclear electromagnetic pulse (EMP). The primary goal is to help decision-makers in the electric power sector have the knowledge and tools they need to most effectively mitigate GMD effects on our nation’s electric grid, with a secondary focus on EMP. Comprehensive modeling, model assessment through sensitivity analysis, and validation with field measurement data will be the primary tasks undertaken. The goal will be a more widespread adoption of these modeling approaches, namely characterizing the uncertainty associated with these models and how that uncertainty will affect decision-making by industry. This document summarizes industry requirements for better decision-making tools, informed by feedback from an industry advisory board. These requirements help guide planning and execution of the project's remaining tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Impact Assessment and Software Tool Requirements

This research project will address the most pressing uncertainties in modeling and measuring the electric power grid effects of geomagnetic disturbances (GMDs) and the E3 portion of nuclear electromagnetic pulse (EMP). The primary goal is to help decision-makers in the electric power sector have the knowledge and tools they need to most effectively mitigate GMD effects on the North American electric grid, with a secondary focus on EMP response. Primary tasks will involve comprehensive modeling,

24 POWER TRANSMISSION AND DISTRIBUTION↗

A section 110 evaluation of the huron king test chamber, area 3, nevada national security site, nye county, nevada

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office tasked Desert Research Institute (DRI) with the identification and evaluation of the Huron King Test Chamber as part of their cultural resources program obligations under Section 110 of the National Historic Preservation Act. The Huron King nuclear test was a vertical line-of-sight weapons effects test that took place in Area 3 on June 24, 1980. Unique to this event was a specially designed aboveground test chamber that held a model defense communications satellite in a vacuum tank meant to replicate the space environment. Sponsored by the Defense Nuclear Agency, the purpose of the experiment was to understand the response of the satellite and its materials and equipment to an electromagnetic pulse and attendant radiation. Between July and August 2022, DRI conducted an archival review on the Huron King experiment and its associated test chamber. Subsequently, pedestrian fieldwork was undertaken at the Huron King Test Chamber by DRI on September 29, 2022. During fieldwork, the outside of the test chamber was documented using a Nevada State Historic Preservation Office Architectural Resource Assessment form. This effort included verifying the substructures that compose the test chamber as determined by the archival review, as well as obtaining a detailed photographic recordation of the exterior and assessing its current condition. Notably, the site where the Huron King test took place has been abandoned and almost entirely naturalized. All of the portable instrumentation trailers, communications and data cabling, and winch systems used to retract the test chamber following the detonation were removed after completion of the experiment in 1980. Only the subsidence crater and the test chamber remain as physical evidence of this experiment. Based on these findings, DRI recommends that the Huron King Test Chamber is eligible for listing in the National Register of Historic Places (NRHP) at the local level under Significance Criteria A and C and that it meets Criteria Consideration G for properties less than 50 years old.

54 ENVIRONMENTAL SCIENCES↗

Gallium nitride electromagnetic pulse arrestor

A GaN diode EMP arrestor exhibits breakdown in <10 ns at reverse-bias voltage >20 kV. Additionally, the arrestor exhibits avalanche ruggedness at 1 kA/cm 2 in a 1 mm 2 device (i.e. 10 A absolute current) over a period of 500 ns following the onset of breakdown. Finally, the specific on-resistance in the forward direction is <20 mΩ cm 2 .

Kaplar, Robert↗

Electromagnetic Pulse in Wide-Angle Gamma Shadows

Unavoidable masses external to the warhead, associated with collateral EMP scenarios of current interest, produce a gamma shadow which changes the EMP seen in the shadowed region compared to that in the absence of a shadow. Calculations with the author’s three-dimensional MACSYNC code for a ground observer under the burst show shadowed field rise times ranging from many tens to hundreds of microseconds, durations approaching a millisecond, and magnitudes similar to those of the unshadowed field, depending on gamma shadow angle. These fields are likely to be smaller for larger observer ground ranges because the source region will shift to higher altitudes with associated higher conductivity that will attenuate the field.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Substation Cable Layouts for EMP Coupling Analysis

Direct coupling of early-time high-altitude electromagnetic pulse (HEMP) to substation control cables is simulated for cable layouts based on surveys of seven electrical substations in the United States. An analytic transmission line modeling code is used to estimate worst-case coupled current at the terminations of cable segments in or near the control shack. Where applicable, an induced voltage due to cable shield grounding is also estimated. Various configurations are simulated, including cables with different elevations, lengths, radii, and terminations. Plots of the coupled HEMP effects are given, and general relationships between these effects and the substations geometric and material parameters are highlighted and discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMP Testing of UL489 Circuit Breakers

Sandia National Laboratories (SNL) is performing a test campaign for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) to address high-altitude electromagnetic pulse (HEMP) vulnerability of critical components of generation stations, with focus on early-time (E1) HEMP. The campaign seeks to establish response and damage thresholds for these critical elements in response to reasonable HEMP threat levels as a means for determining where vulnerabilities may exist or where mitigations may be needed. This report provides component vulnerability test results that will help to inform site vulnerability assessments and HEMP mitigation planning.

42 ENGINEERING↗

Human umbilical cord mesenchymal stem cells regulate CD54 and CD105 in vascular endothelial cells and suppress inflammation in Kawasaki disease

Highlights: • CD31{sup +}CD54{sup +} and CD31{sup +}CD105{sup +} EMPs change inconsistently at different stages of KD, potentially reflect endothelial function. • HucMSCs suppress inflammation and regulate the expression levels of CD54 and CD105 in vascular endothelial cells in KD. • HucMSCs inhibit coronary artery inflammation while also promoting the repair of damaged tissues in KD mice. The objective was to evaluate the expression levels of CD31{sup +}CD54{sup +} and CD31{sup +}CD105{sup +} endothelial microparticles (EMPs) before and after intravenous immunoglobulin (IVIG) treatment of Kawasaki disease (KD). To explore the role of human umbilical cord mesenchymal stem cells (hucMSCs) in inhibiting endothelial inflammation in KD, the effects of hucMSCs on the expression of CD54 and CD105 in endothelial cells in KD were analyzed in vivo and in vitro.

60 APPLIED LIFE SCIENCES↗