Search NASASearch

SEARCH · Search NASA

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

EUV FEL light source based on energy recovery linac with on-orbit laser plasma injection

We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.

43 PARTICLE ACCELERATORS

Performance Improvement of LTS Undulators for Synchrotron Light Sources

The joint expertise of ANL and FNAL has led to the production of $\text{Nb}_{3}\text{Sn}$ undulator magnets in operation in the ANL Advanced Photon Source (APS). These magnets showed performance reproducibility close to the short sample limit, and a design field increase of 20% at 820 A. However, the long training did not allow obtaining the expected 50% increase of the on-axis magnetic field with respect to the ∼1 T produced at 450 A current in the ANL NbTi undulator. To address this, 10-pole long undulator prototypes were fabricated, and CTD-101K was replaced as impregnation material with TELENE, an organic olefin-based thermosetting dicyclopentadiene resin produced by RIMTEC Corporation, Japan. Training and magnet retraining after a thermal cycle were nearly eliminated, with only a couple of quenches needed before reaching short sample limit at over 1,100 A. TELENE will enable operation of $\text{Nb}_{3}\text{Sn}$ undulators much closer to their short sample limit, expanding the energy range and brightness intensity of light sources. TELENE is Co-60 gamma radiation resistant up to 7–8 MGy, and therefore already applicable to impregnate planar, helical and universal devices operating in lower radiation environments than high energy colliders.

43 PARTICLE ACCELERATORS

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication

Results of an interlaboratory study on the working curve in vat photopolymerization II: Towards a standardized method

The working curve measurement in photopolymer additive manufacturing is a ubiquitous measure of the cure depth of a printing resin as a function of radiant exposure of light. The fit parameters from this measurement (the depth of light penetration D p and the critical exposure E c ) are used to evaluate and report a resin’s printability, optimize processing parameters, and inform print and resin quality control. Despite its widespread use, the working curve lacks a standard measurement method. Here, following up on our paper “Results of an Interlaboratory Study on the Working Curve in Vat Photopolymerization” from last year, an interlaboratory study on the working curve was performed using calibrated, reproducible, bandpass filtered light sources. With these light sources, the variability between labs in measured working curves was dramatically reduced from the initial interlaboratory study. Aggregate data from this experiment produced reliable D p and E c measurements at 385 nm of 39.2 ± 3.7 µm and 12.3 ± 3.0 mJ cm −2 , respectively. At 405 nm the values of D p and E c are 69.3 ± 3.8 µm and 17.9 ± 2.3 mJ cm −2 , respectively. The results are agnostic to the thickness measurement tool utilized by participants, ensuring broad applicability across laboratories. We also tested the generalizability of the proposed method of using a filtered light source by filtering a commercial 405 nm light source and obtaining a working curve in agreement with the aggregate data from the interlaboratory study. This interlaboratory study provides a basis for a documentary standard for the working curve, so that the entire photopolymer additive manufacturing industry can share reproducible and interoperable working curve data.

36 MATERIALS SCIENCE

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE

Broadband coherent XUV light from e − / e + microbunching in an intense laser pulse

Attosecond pulses of coherent extreme ultraviolet (XUV) light are instrumental for investigating subatomic dynamics and can be produced using a free-electron laser (FEL). It has been suggested that an optical FEL, which employs a laser pulse in place of a conventional undulator, could enable a dramatically more compact implementation of such a light source. Yet, the high electron density and subsequent high emittance implied by an optical FEL makes this concept challenging to realize with an electron beam. There has been impressive progress in recent years producing collimated dense and relativistic beams of electrons and positrons in the laboratory. As we demonstrate here, the inherent stability of a quasi-neutral electron-positron beam mitigates Coulomb expansion, and renders it a promising alternative source of coherent light. Specifically, we show via computer simulations that broadband coherent light in the XUV domain, which takes the form of 8-as pulses at 92-as intervals, can be generated by microbunching of relativistic electrons and positrons in a laser pulse. This process occurs over a sub-millimeter length scale, enabling the development of light sources which are orders-of-magnitude more compact than existing sources, with potential applications in physics, chemistry, biology, and industry.

47 OTHER INSTRUMENTATION

Characterizing novel Indium Phosphide pad detectors with focused X-ray beams and laboratory tests

Future tracking systems in High Energy Physics experiments will require large instrumented areas with low radiation length. Crystalline silicon sensors have been used in tracking systems for decades, but are difficult to manufacture and costly to produce for large areas. We are exploring alternative sensor materials that are amenable to fast fabrication techniques used for thin film devices. Indium Phosphide pad sensors were fabricated at Argonne National Lab using commercially available InP:Fe 2-inch mono-crystal substrates. Current-voltage and capacitance-voltage characterizations were performed to study the basic operating characteristics of a group of sensors. Micro-focused X-ray beams at Canadian Light Source and Diamond Light Source were used to study the response to ionizing radiation, and characterize the uniformity of the response for several devices. Electrical test results showed a high degree of performance uniformity between the 48 tested devices. X-ray test beam results showed good performance uniformity within tested devices after accounting for spatially-local defects and edge fields. As a result, this motivates further studies into thin film devices for future tracking detectors.

47 OTHER INSTRUMENTATION

Open-source simulation program for extreme ultraviolet and soft x-ray sources based on high-harmonic generation

Light sources based on high-harmonic generation (HHG) underpin ultrafast spectroscopy experiments across a large range of photon energies, spanning from the extreme ultraviolet to the soft x-ray. To this day, their design, implementation, and improvement presens unique challenges, but can be aided by numerical tools. Here we present a new simulation program designed for this purpose, which takes both macroscopic and microscopic aspects of high-harmonic generation into account and is therefore applicable across the broad range of parameters which HHG based light sources are today utilized. The program is validated by comparison with published experimental results and by calculating harmonic emission in four common experimental configurations.

Femtosecond lasers

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION