Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear safeguards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nuclear Safeguards and Nondestructive Assay

What can we do? Encourage/ensure peaceful nuclear uses; Secure, safeguard, and/or dispose of dangerous nuclear and radiological material; Detect and control the proliferation of related WMD technology and expertise.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

AI for Nuclear Safeguards Verification

The International Atomic Energy Agency (IAEA) utilizes AI/ML to analyze open-source information, including satellite imagery and scientific publications, to verify the completeness of State declarations regarding nuclear activities. AI/ML already assist the IAEA with automating processes and analysis of large datasets, including satellite imagery and unstructured data, improving efficiency and effectiveness of safeguards implementation. AI/ML in nuclear safeguards come with its own challenges that include the need for large, unbiased datasets, the risk of AI-generated fake information, including the potential for manipulation of satellite imagery.

97 MATHEMATICS AND COMPUTING↗

Nuclear Safeguards: Feature Extraction for Machine Learning Enrichment Analysis of UF 6 Cylinders

With the increasing international interest in using nuclear material as sources of energy, comes the growing concern that we may see an increase in proliferation threats. Uranium hexafluoride (UF 6 ) is used in the nuclear fuel cycle for uranium enrichment. Inspectors from the International Atomic Energy Agency (IAEA) monitor the enrichment levels of UF 6 stored in transportation cylinders, to ensure the enrichments match that of a facility operator’s declarations. However, only a characteristic subset of UF 6 cylinders can be measured by inspectors from the IAEA during these inspections. In turn, the inspector may not identify a cylinder whose enrichment levels do not match the facility declarations. Therefore, our team attempts to develop a machine learning network that could determine the enrichment percentage of cylinders as they enter and exit facilities. The machine learning model must be robust against spectral variations due to factors that are internal and external to the UF 6 cylinder. Such factors include but are not limited to the speed and distance of the moving vehicle, cylinder type, cylinder orientation, and fill level. Many features in the spectral continuum can be used to identify and correct for some of these variations. As a consequence, the model must extract numerous features in the continuum. We investigate new approaches in continuum subtraction to verify enrichment percentage: interpolation and extrapolation of lines at the notable characteristic spectral peaks. It was determined that there was no clear answer on which method proved superior, therefore the decision was made to implement both new methods into the current codebase. We currently rely on synthetic training and testing data to analyze the results and fine tune our models but hope to test the system on measured data soon.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Design Considerations for the Field Use of International Nuclear Safeguards Technology

The process of developing and deploying safeguards technology should be carried out in such a way that it supports the International Atomic Energy Agency’s (IAEA’s) international safeguards verification mission, while also being efficient in terms of both cost and time. This process, however, may be hindered by a general lack of nuclear facility operating experience among the scientists or engineers designing safeguards technology, or the inability to interact with the IAEA inspector end user. As a result, equipment designers may have difficulty understanding inspector needs and the limitations of using safeguards technology in the field, often leading to inefficiencies (in the form of increased cost and time spent) in the safeguards technology design process. Here, to mitigate this knowledge gap, the Y-12 National Security Complex in Oak Ridge, Tennessee, has developed design considerations that should be incorporated into safeguards technologies, focusing on non-destructive assay equipment. Timelines for integration of these considerations into the design process are also discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nondestructive Assay for Nuclear Safeguards [Slides]

The objective of safeguards is the timely detection of diversion of significant quantities of nuclear material from peaceful nuclear activities to the manufacture of nuclear weapons. Currently, the IAEA is working to achieve universal acceptance of the AP, safeguards-by-design, unattended monitoring & data integration, and state-level concept/approach. We are trying to verify special nuclear material (SNM) is where it should be, and in the proper amount.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV) and verification of spent nuclear fuel while in a cooling pool. EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage. Determination of whether or not spent fuel was present in a fuel rod, as well as the presence/absence of a fuel rod from an assembly using EPV, proved unsuccessful with the sensitivity of instrumentation used in this study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electropotential Verification for Nuclear Safeguards

The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV). EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For large scale infrastructure such as a nuclear facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗