DOE OSTI · 2431886
Electropotential Verification for Nuclear Safeguards
Abstract
The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV) and verification of spent nuclear fuel while in a cooling pool. EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage. Determination of whether or not spent fuel was present in a fuel rod, as well as the presence/absence of a fuel rod from an assembly using EPV, proved unsuccessful with the sensitivity of instrumentation used in this study.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Hamel, Michael C., Baldez, Phoenix, Downs, Christine, Weiss, Chester J., Helguero, Rachel Rae, Bland, Jesse John. 2023-03-01. Electropotential Verification for Nuclear Safeguards. https://doi.org/10.2172/2431886
Cite the original work for its findings. Save a collection to share your selection of sources.