The international safeguards regime desires methods to efficiently verify that facilities are only performing declared activities. Electropotential verification (EPV) is a newly proposed technique that was tested for its feasibility to perform facility design information verification (DIV). EPV works by passing a constant, low voltage current through a conductive system (facility infrastructure of nuclear fuel assembly) and measuring the resulting voltage at various places throughout the infrastructure in order to establish a baseline. Changes made to the system affect these voltage readings, which will deviate from the baseline and indicate that a change to the system was made. For large scale infrastructure such as a nuclear facility DIV, it appears feasible that changes in configuration of the system’s grounding can be detected in real-time, and the location of the change can be inferred from the measured intensity of the change in voltage.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Baldez, Phoenix, Downs, Christine, Hamel, Michael C., Weiss, Chester J., Helguero, Rachel Rae, Bland, Jesse John. 2021-11-01. Electropotential Verification for Nuclear Safeguards. https://doi.org/10.2172/2430139. https://searchnasa.com/record/osti%3A2430139/electropotential-verification-for-nuclear-safeguards
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.