Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shutter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Focal Plane Array Shutter Mechanism of the JWST NIRSpec Detector System

This viewgraph presentation reviews the requirements, chamber location, shutter system design, stepper motor specifications, dry lubrication, control system, the environmental cryogenic function testing and the test results of the Focal Plane Array Shutter mechanism for the James Webb Space Telescope Near Infrared Spectrum Detector system. Included are design views of the location for the Shutter Mechanism, lubricant (lubricated with Molybdenum Di Sulfide) thickness, and information gained from the cryogenic testing.

Hale, Kathleen↗

Technological Developments of NexGen Micro-Shutter Array (NGMSA) for the Future Habitable Worlds Observatory (HWO) Flagship Mission

We present the most up to date advancements in production, design, and performance of the NexGen Micro-Shutter Array (NGMSA) for Multi-object Spectroscopy (MOS), intended for the future Habitable Worlds Observatory (HWO) Flagship. A microshutter array functions as a programmable slit mask, to generate slits corresponding to sparsely distributed sources in the field of view of a telescope. In contrast to the magnetic/electrostatic microshutter arrays used in the James Webb Space Telescope (JWST), the NGMSA is fully operated by electrostatics, simplifying overall system. Our small pilot array proved its capability from FORTIS sounding rocket mission in 2019. As we are switching to a larger HWO flight size array process, we encounter multiple processing related issues. Also, there has been individual shutter level issue that impairs operation and performance. We will discuss those problems and strategies to overcome the challenges to achieve an on/off contrast of >1e5 with near 100% shutter operability.

Microshutter↗

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

Ray-Tracing Simulations Characterizing the Performance of the Proposed 2028 HFIR HB4 Main Shutter

The Main Shutter at HB4 will serve two purposes after the HFIR Beryllium Reflector Replacement, planned to take place in 2028. First as the primary certified safety control permitting the passage of neutrons from the cold source in the HFIR pressure vessel into the cold guide hall, and second as the first set of reflecting surfaces used to guide neutrons from the source and into the individual guide starts for each instrument in the cold guide hall. This report outlines a the simulations and analyses used to conclude that the HB4 Main Shutter Insert alignment is critical to associated instrument performance. In general, the alignment of these surfaces to within +/-0.25 millimeters and +/-0.05° across all dimensions will ensure losses are no worse than 1% for any of the guide starts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Camera shutter is actuated by electric signal

Rotary solenoid energized by an electric signal opens a camera shutter, and when the solenoid is de-energized a spring closes it. By the use of a microswitch, the shutter may be opened and closed in one continuous, rapid operation when the solenoid is actuated.

Neff, J. E.↗

Use of color-coded sleeve shutters accelerates oscillograph channel selection

Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

Bouchlas, T.↗

Multiple shutters for a stereoscopic camera

Focal plane shutter assembly composed of three mechanically separate rotary shutters permits exposure of three separated photographic films simultaneously with exposure time of 0.08 second. Exposure time is repeatable within 2 percent, uniformity of exposure over all three films is within 5 percent.

Marxer, L. W.↗

Rotary shutter mechanism contains optical elements

Two cylindrical shutter mechanisms having fixed outer sleeves and rotating inner sleeves use single stepping motor and Geneva mechanism to sequentially move optical components into path of ultraviolet monochromator for output control to photomultiplier. Photometric and wavelength calibration sources insure shutter positions according to operational phases.

Weilbach, A. O.↗

Shutter mechanism for spacecraft spectrophotometer

A shutter mechanism is described for the backscatter ultraviolet spectrophotometer experiment on the Nimbus D satellite. The purpose of the experiment is to determine spatial distribution of atmospheric ozone from measurements of ultraviolet radiation backscattered by the earth's atmosphere. The system consists of two independent, rotary cylinder shutters, controlled by a dual star Geneva mechanism, and driven by a single stepper motor. A single driver controls a combination of two independently driven Geneva stars. Design considerations involved the use of low friction, nonmetallic materials.

August Weilbach↗

Rotary solenoid shutter drive assembly and rotary inertia damper and stop plate assembly

A camera shutter assembly composed of a pair of superposed opaque planar shutter blades, each having an aperture and being arranged for reciprocal linear movement is disclosed. A pair of rotary solenoids, each connected to one of the blades by a linkage and arranged to be actuated separately at a predetermined interval is provided. An inertia damper and stop plate is built into each solenoid to prevent rebound.

Cable, W. L.↗

Electronic system for optical shutter control

The paper describes a precise and versatile electronic system for shutter control in light beam experiments. Digital and analog circuitry is used to provide automatic timing, exposure control, manual operation, and remote programmability. A block diagram of the system is presented and the individual circuits - the timer control circuit, the clock control circuit, the comparator circuit, the exposure (integrator) circuit, and the shutter drive circuit are discussed in detail and diagrams are provided.

Viljoen, H. C.↗

Cryogenic Shutter Mechanism

Electromagnetic shutter mechanism operates at ambient and cryogenic temperatures to shield optical element, such as mirror, filter, polarizer, beam splitter, or detector, from external light and radiation in cryogenic Dewar equipped with window for optical evaluation. Shutter mechanism in Dewar container alternately shields and exposes optical element as paddle rotates between mechanical stops. Mounted on cold plate of liquid-helium reservoir. Paddle, shaft, and magnet constitutes assembly rotated by electromagnetic field on coil.

Barney, Richard D.↗

Shutter For VPPA-Welding Vision System

Conceptual electro-optical shutter subsystem regulates intensity of light entering video camera from variable-plasma-pulse-arc weld in process. Camera part of video system that enables welding technician to obtain better view of weld bead and puddle in light of arc. Electro-optical shutter opened during low-illumination viewing intervals near zero crossings of welding current, preventing overloading of video camera.

Lirette, Murray J.↗

Shutters and slats for the integral sunshade of an optical reception antenna

Optical reception antennas used at a small Sun-Earth-probe angle (small solar elongation E) require sunshading to prevent intolerable scattering of light from the surface of the primary mirror. An integral sunshade consisting of hexagonal tubes aligned with the segmentation of a large mirror was proposed for use down to E = 12 degrees. For smaller angles, asterisk-shaped vanes inserted into the length of the hexagonal tubes would allow operation down to about 6 degrees with a fixed obscuration of 3.6 percent. Two alternative methods are investigated to extend the usefulness of the integral sunshade to smaller angles by adding either variable-area shutters to block the tube corners that admit off-axis sunlight or by inserting slats (partial vanes) down the full length of some tubes. Slats are effective for most operations down to 6 degrees, and obscure only 1.2 percent. For E between 10.75 and 12 degrees, shutters cause even less obscuration.

Kerr, E. L.↗

A Low Power Cryogenic Shutter Mechanism for Use in Infrared Imagers

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗

A Low Power Cryogenic Shutter Mechanism for use in Infrared Images

This paper discusses the requirements, design, operation, and testing of the shutter mechanism for the Infrared Array Camera (IRAC). The shutter moves a mirror panel into or out of the incoming light path transitioning IRAC between data acquisition and calibration modes. The mechanism features a torsion flexure suspension system, two low-power rotary actuators, a balanced shaft, and a variable reluctance position sensor. Each of these items is discussed along with problems encountered during development and the implemented solutions.

Schwinger, D. Scott↗

Structural Analysis of a Magnetically Actuated Silicon Nitride Micro-Shutter for Space Applications

Finite element models have been created to simulate the electrostatic and electromagnetic actuation of a 0.5 micrometers silicon nitride micro-shutter for use in a spacebased Multi-object Spectrometer (MOS). The microshutter uses a torsion hinge to go from the closed, 0 degree, position, to the open, 90 degree position. Stresses in the torsion hinge are determined with a large deformation nonlinear finite element model. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.

Loughlin, James P.↗