Search NASASearch

SEARCH · Search NASA

Results for “Thermal Control System Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,171 records · Page 2

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Fuel Heating System Design and Thermal Modeling for Aviation Combustion Research

Aviation fuels offer substantial heat-sink capability that can be applied to aircraft thermal-management strategies and advanced propulsion-system concepts. Accurate control of fuel temperature is critical for understanding combustion behavior and supporting high temperature fuel experimental studies. This work describes the modeling and experimental validation of a portable, high temperature fuel-conditioning system designed for multiple NASA Glenn Research Center’s combustion facilities. The system utilizes a circulating-oil heating unit and modular tube-in-tube heat exchangers capable of conditioning Jet-A to temperatures approaching 600 K. A Thermal Desktop model was created to analyze heat exchanger configurations and predict performance across a range of operating conditions. Model predictions were compared with measurements collected in the CE-13C test facility, showing good agreement across the tested flow range except at low fuel flow rate around 2 kg/hr. Results provide guidance for sizing future fuel heating system for combustion research applications.

Jet fuel heating system

Simulated Lunar Gravity Testing of VIPER Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) mission consists of a rover designed to explore the lunar south pole. One of the main challenges faced by the rover during the lunar polar exploration is the adverse thermal environment. Temperatures can fluctuate more than a 100°C between day and night; potentially dropping to −246°C in permanent shadow regions. To maintain the rover components within temperature limits, VIPER’s Thermal Management System (TMS) relies heavily on Loop Heat Pipes (LHPs). To assist the design of the thermal management system, an Engineering Design Unit (EDU) LHP has been tested in several opportunities under thermal vacuum (TVAC) environment. Of particular interest was the LHP performance in lunar gravity. To that end, the EDU LHP was tested at the nominal orientation within the rover assembly, vertical, and inclined such that the gravitational component acting on the LHP evaporator and condenser was 1/6g (lunar gravity is 1/6 of Earth gravity) when compared to the vertical configuration. This paper will examine the LHP conductance as one the key parameters to assess the effect of the gravity on the LHP performance.

Loop Heat Pipe

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY

NASA Systems Autonomy Demonstration Project: Advanced Automation Demonstration of Space Station Freedom Thermal Control System

The NASA Systems Autonomy Demonstration Project (SADP) was initiated in response to Congressional interest in Space station automation technology demonstration. The SADP is a joint cooperative effort between Ames Research Center (ARC) and Johnson Space Center (JSC) to demonstrate advanced automation technology feasibility using the Space Station Freedom Thermal Control System (TCS) test bed. A model-based expert system and its operator interface were developed by knowledge engineers, AI researchers, and human factors researchers at ARC working with the domain experts and system integration engineers at JSC. Its target application is a prototype heat acquisition and transport subsystem of a space station TCS. The demonstration is scheduled to be conducted at JSC in August, 1989. The demonstration will consist of a detailed test of the ability of the Thermal Expert System to conduct real time normal operations (start-up, set point changes, shut-down) and to conduct fault detection, isolation, and recovery (FDIR) on the test article. The FDIR will be conducted by injecting ten component level failures that will manifest themselves as seven different system level faults. Here, the SADP goals, are described as well as the Thermal Control Expert System that has been developed for demonstration.

Jeffrey Dominick

Artemis II Mission Performance of the Orion Active Thermal Control System

The Orion spacecraft has recently completed Artemis II, the first crewed mission around the moon in 54 years. This test flight demonstrated vehicle capability as the foundation for all future missions under the Artemis program. As a major system of Orion, the Active Thermal Control System (ATCS) successfully managed crew and vehicle heat loads to provide adequate cooling and thermal comfort for the duration of the Artemis II mission. Thermal control on the Orion vehicle is managed through two redundant cooling loops in the Crew Module (CM) that absorb heat loads from the cabin and Air Revitalization System (ARS) heat exchangers, the Liquid Cooling Garment (LCG) heat exchanger, and the avionics cold plates, and then transfer those heat loads to the Service Module (SM) radiator loops and/or the Phase Change Material (PCM) and ammonia boilers when required through thermal configuration or mission phase. During Artemis II, Orion did not necessitate any supplemental cooling from ammonia boilers until service module separation, allowing the maximum availability of ammonia cooling prior to entry. This presentation will provide an overview of the Orion ATCS major subsystems, highlight the performance during key mission phases, and comment on the applicability of the observed thermal response to future Artemis missions.

Ellie Thurston

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Development of the METMAN Thermal Desktop Human Model for System Integration

Human thermal analysis and model development inform NASA’s space suit development, vehicle/habitat design, and survivability studies. Historically, human thermal models such as the 41-node metabolic man (METMAN) and the Wissler model have been standalone software tools developed with FORTRAN, a programming language known for its high performance in computationally intensive applications. Though efficient, these standalone programs pose challenges to coupled human-system analysis with detailed life support and thermal control subsystem models in other commercial software. This paper describes the conversion of the METMAN human thermal model from a standalone FORTRAN program to a model in Thermal Desktop (Ansys), a commonly used CAD-based simulation software for engineering that specializes in heat transfer, thermal radiation, and fluid flow analysis. This format was chosen to best facilitate model sharing and compatibility, enabling the direct integration of METMAN human thermal analysis with subsystem models across NASA programs and commercial partners.

Elizabeth Thurston

Microbiological Characterization and Concerns of the International Space Station Internal Active Thermal Control System

Since January 1999, the chemical the International Space Station Thermal Control System (IATCS) and microbial state of (ISS) Internal Active fluid has been monitored by analysis of samples returned to Earth. Key chemical parameters have changed over time, including a drop in pH from the specified 9.5 +/- 0.5 ta = 58.4, an increase in the level of total inorganic carbon (TIC), total organic carbon (TOC) and dissolved nickel (Ni) in the fluid, and a decrease in the phosphate (PO,) level. In addition, silver (AS) ion levels in the fluid decreased rapidly as Ag deposited on internal metallic surfaces of the system. The lack of available Ag ions coupled with changes in the fluid chemistry has resulted in a favorable environment for microbial growth. Counts of heterotrophic bacteria have increased from less than 10 colony-forming units (CFUs)/l00 mL to l0(exp 6) to l0(exp 7) CFUs/100 mL. The increase of the microbial population is of concern because uncontrolled microbiological growth in the IATCS can contribute to deterioration in the performance of critical components within the system and potentially impact human health if opportunistic pathogens become established and escape into the cabin atmosphere. Micro-organisms can potentially degrade the coolant chemistry; attach to surfaces and form biofilms; lead to biofouling of filters, tubing, and pumps; decrease flow rates; reduce heat transfer; initiate and accelerate corrosion; and enhance mineral scale formation. The micro- biological data from the ISS IATCS fluid, and approaches to addressing the concerns, are summarized in this paper.

Monsi C Roman

Design Criteria for Integrated Flight/Propulsion Control Systems for STOVL Fighter Aircraft

As part of NASA's program to develop technology for short takeoff and vertical landing (STOVL) fighter aircraft, control system designs have been developed for a conceptual STOVL aircraft. This aircraft is representative of the class of mixed-flow remote-lift concepts that was identified as the preferred design approach by the US/UK STOVL Joint Assessment and Ranking Team. The control system designs have been evaluated throughout the powered-lift flight envelope on Ames Research Center's Vertical Motion Simulator. Items assessed in the control system evaluation were: maximum control power used in transition and vertical flight, control system dynamic response associated with thrust transfer for attitude control, thrust margin in the presence of ground effect and hot gas ingestion, and dynamic thrust response for the engine core. Effects of wind, turbulence, and ship airwake disturbances are incorporated in the evaluation. Results provide the basis for a reassessment of existing flying qualities design criteria applied to STOVL aircraft.

James A Franklin

The Hubble Space Telescope nickel-hydrogen battery design

Details are presented of the HST (Hubble Space Telescope) battery cell, battery package, and module mechanical and electrical designs. Also included are a summary of acceptance, qualification, and vibration tests and thermal vacuum testing. Unique details of battery cell charge retention performance characteristics associated with prelaunch hold conditions are discussed. Special charge control methods to minimize thermal dissipation during pad charging operations are summarized. This module design meets all NASA fracture control requirements for manned missions.

Nawrocki, D. E.

MSFC Thermal Testing Lessons Learned Course. Section 3: Lessons Learned from Protoflight StarBurst Instrument Thermal Vacuum Test

MSFC thermal engineers will be presenting lessons learned while preparing and conducting thermal tests. This course will cover practical real world examples of thermal chamber and vacuum chamber testing from engineering development units to system level testing on flight hardware. Special topics include large scale testing preparation, requirement tailoring from parent documents, and cryogenic development testing.

thermal discipline

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

Mariner Mars 1971 battery design, test, and flight performance

The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

Bogner, R. S.