Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wolter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strategy and calculations for the design of baffles for Wolter Type II telescopes

Spaceflight, stellar pointing telescopes require baffle systems to define the field of view and protect this observational area from stray and scattered light. In the case of near normal incidence telescope systems, the problem consists in controlling the stray/scattered radiation reaching the image plane when circular plates, the primary and secondary mirrors, are the imaging elements. The case addressed in this paper is quite different in that it involves baffling two conical surfaces, i.e., the primary and secondary mirrors of a Wolter Type II telescope. A strategy is described for systematically moving through the telescope system and establishing criteria for placement of baffles. Calculations are given which determine the size and number of permitted baffles as a function of practical physical parameters. Clear options are given for the design of minimum baffle lengths to meet packaging constraints.

Mangus, John D.↗

Replicate Wolter-I x-ray mirrors

Cylindrical (hyperbolic - parabolic Wolter I) mirrors have been electroformed from nickel over an electroless nickel-phosphorous (NiP) plated aluminum mandrel in support of the NASA AXAF-S x-ray spectrometer program. The electroless nickel was diamond turned and polished to achieve a surface finish of 10 angstroms rms or better. Gold was then plated on the nickel alloy after an electrochemical passivation step. Next a heavy layer of pure nickel was plated one millimeter thick with controlled stress at zero using a commercial PID program to form the actual mirror. This shell was removed from the NiP alloy coated mandrel by cryogenic cooling and contraction of the aluminum to release the mirror. It is required that the gold not adhere well to the NiP but all other plated coatings must exhibit good adherence. Four mirrors were fabricated from two mandrels prepared by this method. The area of each part is 0.7 square meters (7.5 square feet).

Engelhaupt, D. E.↗

Grazing-Incidence Neutron Optics based on Wolter Geometries

The feasibility of grazing-incidence neutron imaging optics based on the Wolter geometries have been successfully demonstrated. Biological microscopy, neutron radiography, medical imaging, neutron crystallography and boron neutron capture therapy would benefit from high resolution focusing neutron optics. Two bounce optics can also be used to focus neutrons in SANS experiments. Here, the use of the optics would result in lower values of obtainable scattering angles. The high efficiency of the optics permits a decrease in the minimum scattering vector without lowering the neutron intensity on sample. In this application, a significant advantage of the reflective optics over refractive optics is that the focus is independent of wavelength, so that the technique can be applied to polychromatic beams at pulsed neutron sources.

Gubarev, M. V.↗

Design of Neutron Microscopes Equipped with Wolter Mirror Condenser and Objective Optics for High-Fidelity Imaging and Beam Transport

We present and compare the designs of three types of neutron microscopes for high-resolution neutron imaging. Like optical microscopes, and unlike standard neutron imaging instruments, these microscopes have both condenser and image-forming objective optics. The optics are glancing-incidence axisymmetric mirrors and therefore suitable for polychromatic neutron beams. The mirrors are designed to provide a magnification of 10 to achieve a spatial resolution of better than 10 μm. The resolution of the microscopes is determined by the mirrors rather than by the L/Dratio as in conventional pinhole imaging, leading to possible dramatic improvements in the signal rate. We predict the increase in the signal rate by at least two orders of magnitude for very high-resolution imaging, which is always flux limited. Furthermore, in contrast to pinhole imaging, in the microscope, the samples are placed far from the detector to allow for a bulky sample environment without sacrificing spatial resolution.

47 OTHER INSTRUMENTATION↗

Sputter metalization of Wolter type optical elements

An analytical task showed that the coating thickness distribution for both internal and external optical elements coated using either electron beam or sputter sources can be made uniform and will not affect the surface figure of coated elements. Also, sputtered samples of nickel, molybdenum, iridium and ruthenium deposited onto both hot and cold substrates showed excellent adhesion.

Ledger, A. M.↗

Aberrations for Grazing Incidence Optics

Large number of grazing incidence telescope configurations have been designed and studied. Wolte1 telescopes are commonly used in astronomical applications. Wolter telescopes consist of a paraboloidal primary mirror and a hyperboloidal or an ellipsoidal secondary mirror. There are 8 possible combinations of Wolter telescopes. Out of these possible designs only type 1 and type 2 telescopes are widely used. Type 1 telescope is typically used for x-ray applications and type 2 telescopes are used for EUV applications. Wolter-Schwarzshild (WS) telescopes offer improved image quality over a small field of view. The WS designs are stigmatic and free of third order coma and, therefore, the PSF is significantly better over a small field of view. Typically the image is more symmetric about its centroid. As for the Wolter telescopes there are 8 possible combinations of WS telescopes. These designs have not been widely used because the surface equations are complex parametric equations complicating the analysis and typically the resolution requirements are too low to take full advantage of the WS designs. There are several other design options. Most notable are wide field x-ray telescope designs. Polynomial designs were originally suggested by Burrows4 and hyperboloid-hyperboloid designs for solar physics applications were designed by Harvey5. No general aberration theory exists for grazing incidence telescopes that would cover all the design options. Several authors have studied the aberrations of grazing incidence telescopes. A comprehensive theory of Wolter type 1 and 2 telescopes has been developed. Later this theory was expanded to include all possible combinations of grazing incidence and also normal incidence paraboloid-hyperboloid and paraboloid-ellipsoid telescopes. In this article the aberration theory of Wolter type telescopes is briefly reviewed.

Saha, Timo T.↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Glancing incidence EUV telescopes - Analysis and comparison

Steps in the derivation of generalized surface equations describing either a Wolter or Wolter-Schwarzschild type II extreme ultraviolet telescope are outlined. These surface equations are incorporated in an optical design program where first-order design parameters are varied to produce a number of different series of type II telescopes. These series are then ray traced to compare and analyze the geometric image quality for different designs in terms of minimum rms angular blur and field curvature. Results of an analysis illustrating the dependence of effective area on first-order design parameters are also presented. The differences and similarities between equivalent Wolter and Wolter-Schwarzschild designs are discussed.

Davila, P. M.↗

Theoretical analysis of segmented Wolter/LSM X-ray telescope systems

The Segmented Wolter I/LSM X-ray Telescope, which consists of a Wolter I Telescope with a tilted, off-axis convex spherical Layered Synthetic Microstructure (LSM) optics placed near the primary focus to accommodate multiple off-axis detectors, has been analyzed. The Skylab ATM Experiment S056 Wolter I telescope and the Stanford/MSFC nested Wolter-Schwarzschild x-ray telescope have been considered as the primary optics. A ray trace analysis has been performed to calculate the RMS blur circle radius, point spread function (PSF), the meridional and sagittal line functions (LST), and the full width half maximum (PWHM) of the PSF to study the spatial resolution of the system. The effects on resolution of defocussing the image plane, tilting and decentrating of the multilayer (LSM) optics have also been investigated to give the mounting and alignment tolerances of the LSM optic. Comparison has been made between the performance of the segmented Wolter/LSM optical system and that of the Spectral Slicing X-ray Telescope (SSXRT) systems.

Shealy, D. L.↗

Design Optimization for X-Ray Telescopes

The capability of future X-ray telescopes depends on the quality of their Point Spread Function (PSF) and the size of their field of view. Traditional designs, such as Wolter, and Wolter-Schwarzschild telescopes are stigmatic on the optical axis but their PSF degrades rapidly off-axis. At the optimal focal surface, their PSFs can be significantly improved. We present a simple optimization process for Wolter (W), Wolter-Schwarzschild (WS) and Hyperboloid-Hyperboloid (HH) telescopes that substantially improves the off-axis PSF for either narrow or wide field of view applications. In this paper, we will compare the optical performance of conventional and optimized W-, WS-, and HH-telescopes for a wide range of telescope diameters that can be used to build up future x-ray telescopes.

Saha, Timo T.↗

Design Optimization for X-Ray Telescopes

The capability of future X-ray telescopes depends on the quality of their Point Spread Function (PSF) and the size of their field of view. Traditional designs, such as Wolter, and Wolter-Schwarzschild telescopes are stigmatic on the optical axis but their PSF degrades rapidly off-axis. At the optimal focal surface, their PSFs can be significantly improved. We present a simple optimization process for Wolter (W), Wolter-Schwarzschild (WS) and Hyperboloid-Hyperboloid (HH) telescopes that substantially improves the off-axis PSF for either narrow or wide field of view applications. In this paper, we will compare the optical performance of conventional and optimized W-, WS-, and HH-telescopes for a wide range of telescope diameters that can be used to build up future x-ray telescopes.

Saha, Timo T.↗

Design Optimization for X-ray Telescopes

The capability of future X-ray telescopes depends on the quality of their Point Spread Function (PSF) and the size of their field of view. Traditional designs, such as Wolter, and Wolter-Schwarzschild telescopes are stigmatic on the optical axis but their PSF degrades rapidly off-axis. At the optimal focal surface, their PSFs can be significantly improved. We present a simple optimization process for Wolter (W), Wolter-Schwarzschild (WS) and Hyperboloid-Hyperboloid (HH) telescopes that substantially improves the off-axis PSF for either narrow or wide field of view applications. In this paper, we will compare the optical performance of conventional and optimized W-, WS-, and HH-telescopes for a wide range of telescope diameters that can be used to build up future x-ray telescopes.

Timo T Saha↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

SAO is working with LLNL to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above at NNSA facilities. Our work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter-I multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The mandrels for the custom optics are fabricated at MSFC. In previous contracts, SAO delivered several optics to LLNL with response at various energies. During this present contract period two tasks were carried out. Task1: the coating, replication and characterization of a custom optic with peak response at 22.8 keV, using the custom-designed SANZ mandrels. Task2: carrying out modifications to the coating chamber at SAO to accommodate new, longer, custom-designed mandrels (SANZlong) that will be fabricated at NASA MSFC in FY2020. The longer mandrels are necessary to mitigate end effects observed in the replication process for the small optics currently being fabricated.

36 MATERIALS SCIENCE↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

The Smithsonian Astrophysical Observatory (SAO) is working with Lawrence Livermore National Laboratory (LLNL) to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above for National Nuclear Security Administration (NNSA) facilities. SAO work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The optics are fabricated using an electroform nickel replication technique which has been used to fabricate optics for X-ray astronomy satellites over the past two decades. This technique starts with a figured, polished mandrel from which the optics are replicated. To carry this technique over to fabricate optics for NNSA facilities, several additional barriers had to be overcome to deposit multilayer coatings on integral optics with radii as small as 25 mm. These breakthroughs allow fabrication of optics which meet the spatial and spectral specifications required by NNSA facilities. During this present contract period SAO delivered four custom optics to LLNL with spectral response at or near the Kα line of silver, 22.16 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗