Microstructure Clones

Background: A material’s microstructure drives its material performance. Contemporary crystal plasticity experiments compare full-field strain measurements of polycrystal specimens to models. Because each specimen is unique, it is impossible to know which features of the observed deformation are deterministic vs statistical; thus, differences between model and experiment may or may not be significant. Objective: This paper introduces the invention of microstructure clones. Microstructure clones are 2D oligocrystal specimens that have nearly identical microstructures to remedy the aforementioned experimental limitations. Having specimens with nearly identical microstructures will allow for multiple destructive tests of a microstructure (either as repeats or intentionally different experiments), an ability to “see the future” by providing insight into how a specimen will deform, variability quantification, and experimental investigations of response to small microstructural changes. Methods: This work introduces microstructure clones. Repeatability of these clones is demonstrated in tensile bars of pure nickel. Local strain measurements from digital image correlation are compared between clone specimens and compared to results from a crystal plasticity finite element model. Results: Two sets of microstructure clones were tested in this study and displayed very consistent deformation responses within each clone set. Small observed differences in deformation invite investigation into microstructure stochasticity and the effect of small microstructural and loading differences. Conclusions: Microstructure clones represent a significant shift in understanding structure–property relationships. This work reshapes experimental crystal plasticity to allow for experiments that control for specific variables, quantification of microstructural stochasticity (and other sources of stochasticity), and opportunities for replicating experiments.

Crystal Plasticity↗

Microstructure Clones

Microstructure drives component behavior. Contemporary crystal plasticity studies compare strain measurements of polycrystal specimens to models. Because each specimen is unique, it is impossible to know which differences are significant. In this project, we invented microstructure clones and explored their use in understanding crystal plasticity. Microstructure clones are specimens with nearly identical microstructures, which allows for multiple destructive tests of a microstructure, insight into how a specimen will deform, variability quantification, and the ability to measure the effects of microstructural changes. Several sets of microstructure clones, pure nickel tensile bars, were tested. The techniques of digital image correlation, crystal plasticity finite element analysis, high resolution electron backscatter diffraction, transmission electron microscopy, and dislocation dynamics were used to understand the structural behavior of these microstructures. This work reshapes the fields of crystal plasticity and structure-property relationships by providing a technique to control for specific variables, quantify microstructural stochasticity, and replicate experiments.

36 MATERIALS SCIENCE↗

Methods development towards automated, physics-informed, quantitative quality control of TRISO-SiC

Tristructural-isotropic (TRISO) fuel particles have been developed as a high-performance fuel for use in high-temperature gas-cooled reactor (HTGR) systems due to their high efficiency and stability under both normal and off-normal conditions. Broader deployment of this technology in advanced nuclear applications may benefit from quantitative quality assurance and quality control (QA/QC) methods that directly link TRISO properties to downstream performance. A key TRISO property is the SiC layer microstructure, which influences fission product retention during irradiation. However, existing QA/QC for the TRISO-SiC microstructure comprises only a qualitative visual inspection; therefore, there is a clear opportunity for the development of quantitative methods for TRISO QA/QC. Here, to this end, previous work has demonstrated an image processing approach to grain boundary (GB) identification and subsequent extraction of microstructural metrics; however, extensive twinning within the SiC layer complicates such analyses because twin GBs significantly influence microstructural metrics but are not expected to contribute to fission product transport. This study presents the initial development, training, and testing of an ML-based image segmentation algorithm designed to identify and remove twin GBs from standard backscattered electron micrographs, providing an industrially applicable, quantitative, and physically meaningful QA/QC approach for the TRISO-SiC microstructure. Although pixel-wise performance metrics for the twin predictions are low, the change in grain area and the number of GB pixels after twin removal predicted by the ML workflow are within 1% of the true values calculated using crystallographic data. This suggests that the model is well capable of predicting overall twin boundary structures and grain morphology, and continued advancement of this approach could enable automated, scalable, and physics-informed QA/QC for TRISO-SiC microstructures, supporting the reliable qualification of coated particle fuels for next-generation reactor systems.

Computer vision↗

The Measurement of Grain Size by Electron Beam Backscattered Diffraction

The method of electron back-scatter diffraction provides an analytic means to identify crystalline phase and the grain size of structural materials. The need to utilize imaging parameters consistent with revealing the contributing microstructural scale is often overlooked through packaged imaging scripts. It is shown that imaging parameters consistent with a post processing assessment of low misorientation angles between boundaries are achievable as using pixel sizes on the order of 10 1 nm.

36 MATERIALS SCIENCE↗

Bulk-scale stress–strain hysteresis in layered crystalline solids: A study of graphite and Ti 3 SiC 2

Polycrystalline graphite and the MAX phase Ti 3 SiC 2 are layered crystalline solids with similar deformation mechanisms, including basal slip, ripplocation boundaries (RBs), kink boundaries (KBs), and cracking. The interplay of these mechanisms, notably in energy dissipation, has been much discussed in the past twenty-five years. This study builds upon previous work, investigating deformation with a renewed emphasis on the bulk-scale and given recent findings concerning RBs. Our investigation compares the evolution of energy dissipation, nonlinear recoverable and irrecoverable strain, and damage upon increasing stress for graphite and Ti 3 SiC 2 . Benitez et al.’s (2016) methodology of compressive cyclic loading and post-mortem electron backscatter diffraction (EBSD) to assess the prevalence of kinking based on low-angle grain boundaries (LAGBs) was used. Strains were measured with digital image correlation and EBSD was conducted on Ti 3 SiC 2 leveraging dictionary indexing, which was necessary herein to identify LAGBs accurately. The stress–strain stages of Ti 3 SiC 2 agree with literature on Ti 2 AlC. Damage and energy dissipation were more accelerated in graphite. No significant difference was observed in the fraction of LAGBs between pristine and unloaded Ti 3 SiC 2 . Trends observed and EBSD evidence that KBs were not dominant suggest that RBs are the primary dissipator of energy in both materials.

36 MATERIALS SCIENCE↗

Effects of Strain and Strain Rate on Dynamic Grain Growth and Subgrain Evolution During Plastic Deformation of an Interstitial-Free Steel at 850 ° C

Here, the effects of strain and strain rate on dynamic grain growth (DGG) and subgrain evolution are reported for an interstitial-free steel deformed at 850 ° C. Microstructures produced during tension tests at true-strain rates of 10 -4 and to 10 -3 s -1 true strains ranging from 0.02 to 0.2 were preserved following deformation. These were characterized using electron backscatter diffraction (EBSD), including the application of spherical harmonic transform indexing to produce high-angular-resolution EBSD (HR-EBSD) data. HR-EBSD data resolved the small misorientation angles of subgrain boundaries while imaging much larger data fields than possible with previously available techniques. The resulting data confirmed that steady-state flow stress is inversely proportional to the average subgrain size and that subgrain boundary misorientation angle increases with strain. The following new observations are reported. The rate of DGG increased with respect to time but decreased with respect to strain as strain rate increased. This behavior is rationalized through a simple model using separate rate parameters for the effects of time and strain. Subgrain size was not constant during steady-state deformation, but decreased slowly with increasing strain. Subgrain size distributions and subgrain boundary misorientation angle distributions were measured, and both remained approximately log-normal during steady-state deformation. Subgrain evolution demonstrated no dependence on parent grain size, crystallographic orientation, or Taylor factor. These new data suggest that steady-state flow stress is more likely controlled by the dislocation density internal to subgrains than by the spacing between subgrain boundaries.

dynamic grain growth↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Emergence of complex-regular eutectic patterns in Al–Ge: Observations from correlative nano-imaging

Eutectic solidification exemplifies nonequilibrium pattern formation, making it a well-studied moving boundary problem. Yet the mechanisms behind the formation of complex-regular microstructures – particularly in highly anisotropic systems with a significant volume fraction of a faceted phase – remain poorly understood. Our understanding of such systems is made complicated by the nonlinear interface kinetics and unique growth dynamics characteristic of faceted phases. To address these challenges, we investigate a model Al–Ge eutectic system, where the faceted Ge phase constitutes a substantial volume fraction (~0.35) and where the two solid phases arrange into so-called “fishbone” or “feather” complex-regular patterns. Using synchrotron-based x-ray nano-imaging and nanotomography with high spatial resolution (22 nm per pixel), we capture in real-time the evolution of the solid–liquid interfaces and the resulting three-dimensional microstructures in this faceted/non-faceted eutectic system. By integrating these observations with electron backscattered diffraction, we elucidate the crystallographic biases on the solidification process and the mechanisms driving the formation of such complex-regular microstructures. These findings inform a new growth model for irregular eutectics in (near-)symmetrical phase diagrams, offering insight on advanced microstructural design and processing strategies. More broadly, we demonstrate how interfacial curvature is generated in irregular eutectic alloys and how it depends on the volume fraction of the faceted phase.

36 MATERIALS SCIENCE↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗

Direct observation of strain-enhanced hydrogen segregation and failure at high-angle grain boundaries in nickel

Understanding the mechanisms underlying hydrogen embrittlement remains difficult, even in single-element metals. Both microstructure and stress state influence hydrogen distribution in metals and alloys, which impacts deformation and failure. Here, in this work, we use in-situ Kelvin probe force microscopy (KPFM) to monitor the hydrogen distribution in pure nickel over time at 1.1 % and 3.5 % strain. The sample strained to 3.5 % results in preferential hydrogen segregation to high-angle grain boundaries whereas the sample strained to 1.1 % does not exhibit preferential hydrogen segregation. Optical digital image correlation (DIC) shows that hydrogen charging results in both localized and reduced strains during tensile testing of a notched sample. Later stages of deformation and failure (e.g. microcracking) are studied by using in-situ transmission X-ray microscopy (TXM). TXM reveals nanoscale structural changes to a propagating crack in a hydrogen environment. Localized void growth and secondary cracking occur at grain boundaries near the primary crack front. Correlative electron backscattering diffraction (EBSD) is used to relate the cracking at grain boundaries to the hydrogen segregation observed in KPFM. These findings are unified in a proposed hydrogen embrittlement mechanism that describes the interaction of hydrogen with grain boundaries, and the role of grain boundaries in hydrogen embrittlement.

Grain boundary fracture↗

Strength-ductility synergy through microstructural and compositional heterogeneity in directed energy deposition additive manufacturing of face-centered cubic materials

Directed energy deposition (DED) is an additive manufacturing (AM) process based on welding technology and offers the advantages of large build volume, high deposition rate, and ability to fabricate multi-material parts. Epitaxial continuous columnar grain growth is a characteristic microstructural feature of DED processed alloys. In this study, a bamboo-like microstructure (periodic alternation of equiaxed and columnar structure) was produced by adopting an intermittent deposition strategy in 316L stainless steel and Inconel 625. The formation of a bamboo-like alternating microstructure was confirmed through electron backscattered diffraction (EBSD) analysis. Hardness mapping showed that the columnar to equiaxed transition (CET) occurred at the region right below the fusion line. A finite element (FE) model was used to investigate the relationship between the temperature gradient (G) and the solidification rate (R). The FE model showed a low G/R ratio at the region right below the interface promoting the CET. The grain size and material-dependent deformation behaviors are analyzed using digital image correlation (DIC). The lower deformation on the fine-grain regions observed in DIC analysis is attributed to a higher strain hardening rate, which is confirmed through dislocation density analysis on a tensile-interrupted specimen. The periodically alternating grain size coupled with the microstructural changes caused by intermittent deposition strategy result in a better strength-ductility synergy in both single-material and bimetallic specimens.

36 MATERIALS SCIENCE↗

Nondestructive ultrasonic characterization of a triple-weld-bead wire arc additively manufactured ER70S-6 S-curved wall

Understanding build-scale microstructural variation in wire arc additive manufacturing (WAAM) of low-carbon steels is essential for ensuring consistent structure–property relationships throughout large components. Conventional destructive characterization techniques, such as scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), are time-intensive and limited to localized regions, making comprehensive evaluation of large WAAM structures challenging. In this study, a nondestructive ultrasonic approach was employed to characterize a 252 mm tall ER70S-6 S-curved WAAM wall produced using a triple-bead deposition strategy. Optical and SEM analysis revealed a repeating dual-region microstructure consisting of uniform polygonal ferrite at melt pool centers and heterogeneous ferrite with coarse and fine grains near melt pool boundaries, attributed to cyclic thermal conditions. Longitudinal ultrasonic backscatter imaging was used to evaluate the continuity of this periodicity along the full build height. The ultrasonic response exhibited a consistent repeating pattern that correlated with the observed layer-wise microstructural variation. X-ray computed tomography confirmed the absence of detectable porosity, indicating that ultrasonic contrast is primarily governed by grain morphology. Overall, the results indicate that longitudinal backscatter ultrasound is a promising nondestructive characterization technique for validating microstructural variations along the s-curved WAAM wall, with significant potential for microstructure optimization and process control.

36 MATERIALS SCIENCE↗

Effect of Heat Treatment on Microstructure and Mechanical Property of 316L Stainless Steel Produced by Laser Powder Bed Fusion

The advanced non-light water reactor designs (Gen IV reactors), including molten salt/ very high temperature/ sodium-cooled and lead-cooled fast reactors, typically operate at higher temperatures and more extreme radiation conditions than light water reactors. An intrinsic part of the deployment and progress of Gen IV reactor designs is selecting the most suitable structural material for a specific application. Additive manufacturing (AM), a fairly new process of making physical, three-dimensional objects from a computer design file, is going to completely change the way of design, build and certify nuclear systems. It offers a range of opportunities to produce complex geometries from existing materials, offers new routes for processing of previously difficult to process materials, allows for design of new high-performance materials, and finally facilitates hybridization of dissimilar materials. This emerging technology has successfully produced cars, wind turbine blade molds and even live cells. It could also open up big opportunities for the nuclear industry to quickly deploy technologies at a fraction of the cost. So far, AM techniques have been preliminarily applied in the field of nuclear reactors, including the classical parts such as the pressure vessel of a small reactor with 508-III steel, the bottom nozzle of a fuel assembly with 304L steel, the fuel cladding with zirconium alloy and the integrated impeller of a pump and the multi-channel valve body with 316L steel [6,7]. The AM applications for operating nuclear reactors started in auxiliary plant components and have slowly migrated to metallic reactors and core components, but many of these are not safety critical components. Although many parts used for nuclear reactors have been fabricated by AM techniques, practical applications in engineering are still a long way off due to the uncertainty factors focused on the processing, material properties, analysis methods and application standards, which feeds the safety and life-cycle of the nuclear reactor. Due to rapid, repeated heating and cooling during production, a high dislocation density was present in the AM material. This microstructure feature is unstable at elevated temperature while high temperature is one of the typical operation environments for nuclear reactors. Thus, it is important to understand the thermal effect on the microstructure of AM material. The objectives of this study are to investigate the effect of heat treatment on the microstructure and mechanical properties of 316L stainless steel produced by laser powder bed fusion additive manufacturing, and to determine an appropriate heat treatment practice that will be applied to the lightweight AM lattice-structured material with the same chemistry. The heat treatment study consisted of annealing the samples at a temperature range of 800 to 1200 oC with a 50 oC increment for different times (1-24 hours), followed by vacuum or air cooling. Microstructural characterization was carried out by Scanning Electron Microscope (SEM). Grain size and crystallographic orientation were investigated by Electron Backscatter Diffraction (EBSD). Vickers hardness tests with a 0.5 kg load were employed to determine the hardness of samples after different heat treatments. After heat treatment, the random crystallographic orientation was preserved, and the volume fraction of high-angle grain boundaries (grain boundary misorientation =15 oC) remained the same. The dislocation density decreased with annealing temperature due to recovery. The fine subgrain structures in the as-printed specimen were quite stable up to 1200 oC. Minimal recrystallization was observed up to 1200 oC. Recrystallization initiated only after 8.5 hours at 1200 oC. The SEM images did not show obvious dependence of microstructure on cooling rate. The hardness of the specimens decreased with increasing annealing temperature as a result of the decrease in dislocation density. It is interesting to note that the AM material showed very similar hardness to the wrought material when annealing at similar temperature, although the microstructures are very different. Annealing at 1050 oC for 1 hour followed by air cooling was selected as the heat treatment procedure for the lattice designed lightweight AM 316L material.

36 MATERIALS SCIENCE↗

Dynamic and quasi-static strength of additively repaired aluminum

Additive manufacturing has the potential to repair high value components, saving significant time and resources; however, the level of reliability and performance of additive repairs is still relatively unknown. In this work, the structure–property and performance of laser wire additive manufacturing repairs in 1100 aluminum are investigated. Two types of intentional damage are inflicted on the samples and subsequently repaired with pulsed laser deposition additive manufacturing. Quasi-static (10 –3 s –1 ) and high strain-rate (10 –3 s –1 ) mechanical testing is carried out with in situ diagnostics and post-mortem imaging. The results show that while the quasi-static strength and ductility of samples with a repaired region are lower than a pristine sample, the dynamic strength under shock loading is comparable. This work highlights both the potential utility of additive manufacturing for repair purposes, the significant risk of compromised performance of additive parts under specific conditions, and the need to test at varying strain rates to fully characterize material performance.

36 MATERIALS SCIENCE↗

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE↗

Real-time steerable frequency-stepped Doppler backscattering (DBS) system for local helicon wave electric field measurements on the DIII-D tokamak

A new frequency-stepped Doppler backscattering (DBS) system has been integrated into a real-time steerable electron cyclotron heating launcher system to simultaneously probe local background turbulence (f < 10 MHz) and high-frequency (20–550 MHz) density fluctuations in the DIII-D tokamak. The launcher allows for 2D steering (horizontally and vertically) over wide angular ranges to optimize probe location and wavenumber response. The vertical steering can be optimized during a discharge in real time. The new DBS system employs a programmable frequency synthesizer with adjustable dwell time as a source to launch either O or X-mode polarized millimeter waves. This system can step in real-time over the entire E-band frequency range (60–90 GHz). This combination of capabilities allows for the diagnosis of the complex internal spatial structure of high power (>200 kW) helicon waves (476 MHz) injected from an external antenna during helicon current drive experiments in DIII-D. Broadband density fluctuations around the helicon frequency are observed during real-time scans of measurement location and wavenumber during these experiments. Analysis indicates that these broadband high-frequency fluctuations are a result of backscattering of the DBS millimeter-wave probe beam from plasma turbulence modulated by the helicon wave. It is observed that background turbulence is effectively locally “tagged” with the helicon wave electric field, forming images of the turbulent spectrum in the overall density fluctuation spectrum that appear as high-frequency sidebands of the turbulence. These observations of background turbulence and high-frequency fluctuations open up the possibility of monitoring local helicon wave amplitude by comparing the high-frequency signal amplitude to the simultaneously measured background turbulence. In combination with the real-time measurement location and wavenumber scanning capabilities (offered by real-time frequency-stepping and steering), this allows rapid determination of the spatial distribution of the helicon wave power during steady-state plasma operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗