Search NASASearch

SEARCH · Search NASA

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a key limitation to achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. Addressing this challenge requires a detailed understanding of the generation and transport of FE-induced radiation; however, the absence of standardized measurement protocols complicates comparisons across different testing stages and facilities. This work presents initial steps toward a quantitative, systematic framework for analyzing FE-induced radiation using Geant4 simulations. We model four cavity types to be deployed in Fermilab’s Proton Improvement Plan-II (PIP-II) linac - HB650, LB650, SSR2, and SSR1 - to investigate radiation signatures and their dependence on emission conditions. By integrating simulation results with radiation diagnostics, our goal is to identify probable emission sites, enhance diagnostic accuracy, and optimize detector placement. Ultimately, this approach seeks to inform cavity preparation, assembly, and testing procedures, enabling the delivery of FE-free SRF cryomodules for PIP-II.

Wijethunga, Sajini [Fermilab] (ORCID:0000000287659

Fast and High-Fidelity SNAP Gate Enabled by Optimal Control on Floquet-Engineered Systems

Superconducting cavities with high quality factors, coupled to nonlinear ancilla, provide a promising platform for quantum information storage and manipulation. However, the commonly used selective number-dependent arbitrary phase (SNAP) gate faces significant challenges in ultra-high-coherence cavities, where weak dispersive shifts result in prolonged gate times. Here, we propose a protocol to achieve high-fidelity SNAP gates that are orders of magnitude faster than the standard implementation, breaking the speed limit set by the bare dispersive shift. This enhancement is achieved by dynamically amplifying dispersive coupling via sideband interactions, followed by quantum optimal control on Floquet-engineered systems. Additionally, we present a unified perturbation theory that explains both the gate acceleration and associated benign drive-induced decoherence, corroborated by Floquet\textendash Markov simulations. These results pave the way for the experimental realization of high-fidelity control of weakly coupled, high-coherence cavities, and expanding the scope of optimal control techniques in Floquet quantum systems.

You, Xinyuan [Fermilab]

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Extreme Longitudinal Compression of Optimized Beams for MEV Ultrafast Electron Diffraction (Final Technical Report)

We worked out the design of a high repetition rate MeV energy ultrafast electron diffraction instrument based on the existing Cornell photoinjector, which can readily be applied to the presented findings. This example is a blueprint of other similarly arranged UED setups. Using particle tracking simulations in conjunction with multiobjective genetic algorithm optimization, we explored the smallest bunch lengths, emittance, and probe spot sizes achievable. As two limits, we defined stroboscopic conditions (with single electrons per pulse) and operation with 10 5 electrons per bunch which may be suitable for single-shot diffraction images. In the stroboscopic case, the flexibility provided by the many cavity bunching and acceleration allows for longitudinal phase space linearization without a higher harmonic field, providing sub-fs bunch lengths at the sample. Given low emittance photoemission conditions, these small bunch lengths can be maintained with probe transverse sizes at the single micron (1 μm) scale and below. In the case of 10 5 electrons per pulse, we simulated state-of-the-art 5D brightness conditions: rms bunch lengths of 10 fs with 3-nm normalized emittances, while permitting repetition rates as high as 1.3 GHz. We showed that in conjunction with collimating apertures, a novel focusing scheme achieves very high-quality emittance compensation for the central core of the beam composing 40% of particles, for a resulting beam size of 5 μm (rms). Finally, to aid in the design of new SRF-based ultrafast electron diffraction machines, we simulated the trade-off between the number of cavities used and achievable bunch length and emittance. In the longitudinal dimension, we made use of the fact that MeV UED requires much lower energy than the 15-MeV maxi mum energy of Cornell’s CBETA injector, and we may therefore use several of the SRF cavities for bunch length compression. In practice, we used a genetic optimization algorithm to choose the phases and amplitudes of the cavities appropriately for optimal bunching. In the zero space charge case, we found that bunching and acceleration are distributed across the six cavities in a way that produces a linearizing effect. And we showed that the ultimate bunch length can be limited by time-of-flight differences arising from transverse size and transverse momentum spread. The space charge code developed and used for this development is now permanent part of the Bmad accelerator simulation code and has already contributed to other developments, e.g., for the EIC electron cooler design.

43 PARTICLE ACCELERATORS

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765

Study on Electropolishing of N-Doped Niobium Surfaces and 650 MHz Cavity for High-Gradient Performance

This presentation provides an overview of the latest studies on electropolishing (EP) of nitrogen-doped niobium surfaces and 650 MHz cavities. The first study focuses on optimizing EP parameters to achieve a pit-free surface on N-doped niobium, highlighting the effects of process conditions on surface pitting and suggesting strategies for mitigation. The second study investigates the EP of 650 MHz cavities to achieve high-gradient performance comparable to that of 1.3 GHz niobium SRF cavities. Additionally, an example of a 650 MHz single-cell cavity is presented, demonstrating its record-high gradient achieved through optimized EP conditions.

43 PARTICLE ACCELERATORS

Nb 3 Sn coating of SRF cavity by cosputtering from a composite target

Here, we deposited an Nb 3 Sn film on the inner surface of a 2.6 GHz Nb superconducting radio frequency cavity by cosputtering using a composite of Nb and Sn tube targets in a DC cylindrical magnetron sputtering system, followed by the thermal annealing of the coated cavity. An aluminum mockup cavity, replicating a 2.6 GHz Nb SRF cavity geometry, was utilized to optimize deposition parameters, resulting in cosputtered Nb–Sn films with an Sn content of 32–42 at. % on the beam tubes and equator positions. Several annealing conditions were investigated to improve the surface homogeneity of the Nb 3 Sn film. The best cosputtered Nb–Sn film was achieved after annealing at 600 °C for 6 h, followed by annealing at 950 °C for 1 h. The best process was applied to a Nb cavity, which was RF tested in a cryogenic dewar. RF testing of the Nb 3 Sn-coated cavity demonstrated a superconducting transition temperature of 17.78 K. The Nb 3 Sn cavity underwent light Sn recoating, followed by additional RF testing, resulting in the enhancement of the RF performance, primarily due to the improved surface homogeneity of the Nb 3 Sn coating.

Nb3Sn film

IOTA Experiment for Proton Pulse Compression at Extreme Space-Charge

The longitudinal compression of high-intensity, space-charge-dominated proton bunches is a critical requirement for future proton-driven muon colliders. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to investigate optimal radio-frequency (RF) cavity parameters and lattice configurations. IOTA is a compact, fixed-energy storage ring dedicated to beam physics Research and Development and capable of circulating a 2.5 MeV proton beam under extreme space-charge conditions. Using the ImpactX code with its 3D space-charge solver, simulations indicate that the bunch length can be rapidly reduced by at least a factor of two without appreciable degradation of transverse beam quality--even in the strong space-charge regime. However, longitudinal defocusing due to the space-charge remains a significant challenge in short-pulsed intense proton bunches, and the optimization of compression under these conditions is discussed.

Simons, B. D. [Northern Illinois U.]

VSR SRF HOM load and waveguide

Under the expired ICRADA JSA2012S015 mod 5, JLab collaborated with HZB to design and prototype the high power HOM load for HZB VSR upgrade 1.5GHz cavities and bERLinpro cavities, as well as the optimization of the HOM waveguide thermal design. The scope of work to be contracted with this ICRADA includes: finalize the HZB VSR HOM load design for production; fabricate, test and deliver 30 HOM loads to HZB; design and prototype the HZB VSR HOM waveguide assembly.

43 PARTICLE ACCELERATORS

LLRF System Analysis for the Fermilab PIP-II LINAC

Developing long-lived quantum processing units (QPUs) capable of supporting high-fidelity quantum operations is a crucial challenge on the path toward fault-tolerant quantum computing. TESLA-shaped superconducting RF (SRF) cavities, known for photon relaxation times on the order of seconds, provide an excellent foundation for 3D QPUs and quantum memory. This talk presents a novel design that leverages TESLA cavity modes coupled to ancillary transmon qubits, optimized to preserve coherence and control. By carefully engineering the package geometry, optimizing Hamiltonian parameters, and minimizing lossy participation ratios, we achieve photon relaxation times of over 16 ms and 20 ms for the two cavity modes, representing a significant improvement over previous multimode quantum memories. Despite the reduced coupling between the qubit and cavity modes, which is necessary to preserve long lifetimes, the platform supports robust and universal control schemes that are not limited by low coupling strength. We will also discuss how this architecture can lead to scalable, modular quantum computing systems.

Varghese, P. [Fermilab]

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Correlating Nb-SRF Surface Processing with Evolution of Surface Electronic States

The few nanometers of the surface exposed to RF field plays a major role in defining the RF performance of superconducting cavities. Over the past two decades, several pioneering surface treatment and processing methods have emerged, enabling remarkable improvements in cavity performance by simultaneously achieving high Q with increasing Eacc. These processing methods include: thermal treatment under ultra-high vacuum (UHV) conditions across lo¬¬¬¬¬¬¬w-, mid-, and high-temperature ranges and high temperature treatments under controlled N2 atmosphere. These processes also produce distinct surface oxide configurations with different valence states, thicknesses, and uniformity, as well as different oxygen concentration profiles in bulk Nb. In this work, we are trying to understand how do surface-processing methods and the resulting oxide/oxygen profiles affect the electronic structure of surface and the mechanism of superconductivity? With the help of Fermilab’s in-house X-ray photoemission facility and, in collaboration with the synchrotron-based angle-resolved photoemission (ARPES) facility at Argonne National Laboratory, we are investigating how the valence band structure and density of states (DoS) near the Fermi level modify with different surface treatments. Our observations show that different surface-processing methods lead to distinct evolutions of the valence-band states near the Fermi level during the superconducting transition. This behavior suggests variations in Nb-O orbital hybridizations and points towards the possibility of different underlying mechanisms of superconductivity governed by the surface chemistry and oxide configuration. We also correlate these distinct superconducting mechanisms with RF cavity performance, specifically focusing on measured surface resistance, the nature of the Q-slope, and quench fields observed in SRF measurements. These results will enable us to identify the potential limiting factors and relevant controllable parameters that can be further optimized to improve the performance of SRF cavities.

Tripathi, Malvika [Fermilab]

Predicting multiphase flow and tracer transport for an underground chemical explosive test

Detecting radionuclide gas seepage from clandestine underground nuclear tests is central to nonproliferation explosion monitoring research. Yet, early-time (<6 day) gas transport driven by the explosive pressure wave remains poorly constrained due to scarcity of field data. We simulate multi-phase gas transport in the vadose zone using pre-shot data from a recent chemical explosion in P-Tunnel at the Nevada National Security Site, USA. Despite using a simplified 2D-radial model, predictions of tracer arrival matched observations within one order-of-magnitude. Our results show how transient blast forcing rapidly mobilizes gases from the cavity into surrounding rock – critical for optimizing sensor placement and test planning. This unique integration of field data and modeling represents a significant improvement in our ability to predict gas migration from underground explosions. More broadly, it offers insights into the coupled dynamics of pressure waves and contaminant transport in the vadose zone, with implications for monitoring and hazard assessment.

54 ENVIRONMENTAL SCIENCES

Thermal Stability of the Dot-in-Well Gain Medium for Photonic Crystal Surface Emitting Lasers

Self-assembled quantum dots (QDs) embedded in InGaAs quantum wells (QWs) are used as active regions for photonic-crystal surface-emitting lasers (PCSELs). An epitaxial regrowth method is developed to fabricate the dot-in-well (DWELL) PCSELs. Here, the epitaxial regrowth starts with the growth of a partial laser structure containing bottom cladding, waveguide, active region, and the photonic crystal (PC) layer. The PC layer is patterned to realize the cavity. Subsequently a top cladding layer is regrown to complete the laser structure. During the regrowth of the top cladding layer, the partial laser structure is subjected to high growth temperatures in excess of 600 °C resulting in an unintentional annealing of the active region. This annealing of the active region can alter the QDs by changing their size resulting in a blue shift in photoluminescence (PL) and narrowing PL emission. This effect results in the misaligning of the gain peak and the cavity resonance, resulting in sub-optimal lasing performance. DWELL active regions are known to have better thermal stability compared to both QDs and QWs and could be an ideal candidate for regrown PCSELs. We successfully demonstrate an optically-pumped epitaxially-regrown DWELL PCSEL with an emission wavelength of 1230 nm operating at room temperature. Furthermore, the DWELL active region shows excellent emission wavelength stability and intensity despite the high temperature regrowth process.

77 NANOSCIENCE AND NANOTECHNOLOGY

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION