Search NASASearch

SEARCH · Search NASA

Results for “charge and discharge heat loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,673 records · Page 2

Catalytic disproportionation on carbon superstructures enables long-life, high-loading Li–S batteries

Electrocatalysis has been widely explored as an effective strategy to accelerate polysulfide (PS) conversion and suppress the shuttle effect in lithium–sulfur (Li–S) batteries. However, the underlying mechanisms remain elusive, and electrocatalytic reactions are inactive during cell resting. In this work, we reveal and quantitatively analyze a previously unrecognized sulfur reduction route (SRR) driven by catalytic disproportionation at the carbon cathode surface—fundamentally distinct from conventional electrocatalysis. Unlike conventional stepwise pathways, this SRR enables high-order polysulfides (Sₓ²⁻, x = 5–8) to directly convert into S₈ and Li₂S₂, bypassing low-order intermediates. This sulfur-reduction shortcut is systematically elucidated through high-performance liquid chromatography, revealing the intrinsic catalytic contribution of carbon frameworks and the dynamic evolution of PS species. We demonstrate that carbon superstructures (CSS-0.5), assembled from nanosheet subunits with abundant N/O functionalities and interconnected charge-migration channels, synergistically promote this catalytic process. Benefiting from these features, CSS-0.5 delivers superior electrochemical performance under practical conditions, enabling high sulfur loading (6.0 mg cm⁻²) pouch cells with 80.5% capacity retention over 210 cycles. This study provides the first quantitative evidence of electrocatalytic disproportionation in Li–S batteries, offering mechanistic insights and design principles for advanced sulfur cathodes.

25 ENERGY STORAGE

Interfacial Adhesion Mechanism of Anionic Polyelectrolyte Brushes Induced by Oppositely Charged Macromolecular Counterions

Abstract Polyelectrolyte brushes are widely used as model systems for investigating electrostatic interactions at soft interfaces and to achieve exceptional lubrication properties. Previous studies have primarily focused on their behavior in the presence of multivalent counterions, which induce brush collapse, ionic crosslinking, and pronounced changes in interfacial structures. However, interactions between polyelectrolyte brushes and oppositely charged macromolecular counterions, such as polycations, remain poorly understood. Here, we prepare well-defined polystyrene sulfonate (PSS) brushes fabricated via surface-initiated grafting and employ surface forces apparatus measurements to investigate their interactions with oppositely charged polycations. In contrast to multivalent ions, polycations do not induce noticeable brush collapse, but instead generate significant adhesion between symmetric PSS brush layers. This adhesion increases with both contact time and applied load, eventually reaching a steady plateau, indicating that the interaction is governed not simply by electrostatic screening but by the gradual formation of polycation-mediated bridging under confinement. Furthermore, the introduction of monovalent Na+ ions disrupts the adhesive interaction even at very low concentrations, suggesting that the bridging function of the adsorbed polycation is highly sensitive to competitive ionic screening. In comparison, measurements with trivalent counterions reveal the expected brush collapse behavior but minimal dependence of adhesion on contact time, highlighting a clear mechanistic distinction from the polymeric counterion case. Collectively, these results demonstrate that molecular size, configurational restriction, and confinement-induced rearrangement, rather than charge valency alone, govern the interaction behavior of macromolecular counterions at brush interfaces. This work provides new insight into the molecular origins of adhesion and the regulation of interfacial interactions in charged polymer brush systems.

Park, Jinwoo [Argonne National Laboratory , , , ,;

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY

Research and Development on Advanced Electrochemical Energy Storage Devices Enabling a Spectrum of Electrified Vehicles

The USABC Advanced Battery development plan had the following three focus areas: 1. Existing technology validation, implementation, and cost reduction 2. Identification of the next viable technology with emphasis on the potential to meet USABC cost and energy density goals. 3. Support high-risk, high-reward battery technology R&D The primary aim of this project was focused on the barriers that most impede wider public adoption of electrification in vehicles-cost, energy density, low-temp performance, calendar life, and improvements in abuse tolerance. The specific objectives are as follows: Cost Reduction: drive to significantly reduce battery cost to be in-line with the $\$$100/kWh or less (by the end of calendar year 2020) DOE cost goals. Additionally, goals of $\$$75/KWh were set for 2023 aligned with fast charge and some offset of energy density. Energy Density Increase: focus on improving the cell-level specific energy and energy densities to >350 watt hours per kilogram (Wh/kg) and >750Wh/L. Low Temperature Performance Increase: strive toward developments that improve the discharge power and eliminate or dramatically reduce the life limiting lithium plating associated with regenerative braking at low temperatures, during the program. Calendar Life Increase: drive to achieve a 15-year calendar life. Abuse Tolerance Improvement: strive to develop improvements in Li-ion abuse tolerance and/or development of electrochemical energy storage technologies with inherently better response to abuse circumstances. Emerging Areas: initiate new programs that address emerging technologies that arise during the contract period.

25 ENERGY STORAGE

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili

Review on Preprocessing Strategies, Deactivation, Thermal Safety, and Future Perspectives in Lithium-Ion Battery Recycling

The rapid growth in the use of lithium-ion batteries (LIBs) in electric vehicles, consumer electronics, and renewable energy storage has made effective end-of-life management essential. Recycling LIBs is critical not only for resource recovery and environmental protection but also for ensuring safety and economic viability. This review focuses on the preprocessing technologies that precede typical recovery processes, including disassembly, sorting, discharging, electrolyte removal, dismantling, thermal treatment, separation, and flotation. These steps play a foundational role in determining the efficiency, safety, and environmental impact of LIB recycling. LIBs pose substantial fire and explosion risks due to residual charge, flammable electrolytes, and reactive materials. The conditions and successive progression of the exothermic reactions which lead to thermal runaway has been discussed. It also explores secure deactivation techniques such as external circuit discharge, saline immersion, and thermomechanical methods, alongside fire prevention strategies including the use of flame retardants, elimination of oxidants, and reduction of heat generation and accumulation. Challenges and future directions are outlined, highlighting the need for standardized designs, automation, and safer, more sustainable recycling infrastructure. Furthermore, this review is distinguished by its focused analysis of preprocessing and deactivation steps, with particular attention to the thermal safety engineering aspects of LIB recycling.

Battery deactivation

Modeling a generic TRISO-fueled heat pipe microreactor using SCALE: Depletion, transportation criticality, and shielding

This paper demonstrates the applicability of the SCALE code system to tristructural-isotropic (TRISO)-fueled heat pipe microreactors through depletion, transportation criticality, and shielding analyses of a generic reference design. The study conducted supports US Nuclear Regulatory Commission code readiness efforts for advanced non–light-water reactor technologies and is intended as a code capability demonstration rather than as an optimization of a specific microreactor design. The modeled reactor employs high-assay low-enriched uranium (HALEU) uranium oxycarbide (UCO) TRISO fuel and beryllium oxide (BeO) reflectors and operates at 7.5 MWth with a nominal lifetime of about 3 effective full power years. Representative cases for fresh and irradiated cores were selected to exercise SCALE methods relevant to reactor operation and post-irradiation transport. The discharged-core decay heat is approximately 6% of operating power immediately after shutdown. Transportation criticality calculations show that internal water ingress is the dominant reactivity effect, with fully flooded fresh core and irradiated core configurations remain above the subcriticality criterion, even with the available control mechanisms. Shielding calculations for a simplified transportation package indicate that normal-condition dose rates are governed mainly by shielding thickness and cooling time, whereas the breached hypothetical accident case is governed primarily by cooling time. Overall, the study shows that SCALE supports depletion, transportation criticality, and shielding evaluations efficiently for TRISO-fueled heat pipe microreactors within a single code system.

Criticality

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Optimization of the FRIB beam dump: a hybrid genetic algorithm and reinforcement learning approach

The operational envelope of high-power-density systems, such as particle accelerators and advanced nuclear energy systems, is critically constrained by the need to manage extreme thermal loads. To address this, we present a novel hybrid optimization framework combining a genetic algorithm (GA) with a soft actor-critic (SAC) deep reinforcement learning agent. This framework was applied to a practical high-heat-flux problem: redesigning the beam dump at the Facility for Rare Isotope Beams (FRIB) for a power upgrade from 20 kW to 50 kW. The resulting design, validated by three-dimensional conjugate heat transfer simulations, suppresses hazardous hot spots and yields a markedly more uniform temperature distribution. This provides a robust operating margin, increasing the average power-handling capability by 72% relative to the current design, demonstrating the framework’s potential to solve complex thermal management challenges in both accelerator technology and advanced nuclear systems.

Accelerator

From Pollutant Removal to Renewable Energy: MoS2-Enhanced P25-Graphene Photocatalysts for Malathion Degradation and H2 Evolution

The widespread presence of pesticides—especially malathion—in aquatic environments presents a major obstacle to conventional remediation strategies, while the ongoing global energy crisis underscores the urgency of developing renewable energy sources such as hydrogen. In this context, photocatalytic water splitting emerges as a promising approach, though its practical application remains limited by poor charge carrier dynamics and insufficient visible-light utilization. Herein, we report the design and evaluation of a series of TiO2-based ternary nanocomposites comprising commercial P25 TiO2, reduced graphene oxide (rGO), and molybdenum disulfide (MoS2), with MoS2 loadings ranging from 1% to 10% by weight. The photocatalysts were fabricated via a two-step method: hydrothermal integration of rGO into P25 followed by solution-phase self-assembly of exfoliated MoS2 nanosheets. The composites were systematically characterized using X-ray diffraction (XRD), Raman spectroscopy, transmission electron microscopy (TEM), UV-Vis diffuse reflectance spectroscopy (DRS), and photoluminescence (PL) spectroscopy. Photocatalytic activity was assessed through two key applications: the degradation of malathion (20 mg/L) under simulated solar irradiation and hydrogen evolution from water in the presence of sacrificial agents. Quantification was performed using UV-Vis spectroscopy, gas chromatography–mass spectrometry (GC-MS), and thermal conductivity detection (GC-TCD). Results showed that the integration of rGO significantly enhanced surface area and charge mobility, while MoS2 served as an effective co-catalyst, promoting interfacial charge separation and acting as an active site for hydrogen evolution. Nearly complete malathion degradation (~100%) was achieved within two hours, and hydrogen production reached up to 6000 µmol g−1 h−1 under optimal MoS2 loading. Notably, photocatalytic performance declined with higher MoS2 content due to recombination effects. Overall, this work demonstrates the synergistic enhancement provided by rGO and MoS2 in a stable P25-based system and underscores the viability of such ternary nanocomposites for addressing both environmental remediation and sustainable energy conversion challenges.

Chemistry

Revealing key structures for reversible sulfur redox in amorphous polymeric sulfur

Amorphous polymeric sulfur cathodes, such as sulfurized polyacrylonitrile (SPAN), enable high-energy lithium-sulfur batteries without cobalt or nickel, leveraging abundant sulfur. However, the limited in situ understanding of their synthesis and electrochemistry has impeded targeted optimization. Here, in this study, we integrate operando high-energy total scattering with sulfur K-edge X-ray absorption spectroscopy to monitor SPAN's formation and cycling in real time. Our results show that S-C bond formation halts further fusion of cyclized polyacrylonitrile, fostering π-π stacking and a transition from long-chain to short-chain sulfur-critical for reversible sulfur redox. These features synergistically minimize polysulfide dissolution and charge-transfer resistance, enabling optimized SPAN to achieve high capacity retention over 1,000 cycles. Operando X-ray absorption spectroscopy reveals that residual protons drive thiol-thione tautomerism, with lithium replacement during the first discharge causing ~20% irreversible capacity loss. To enhance performance, minimizing -NH groups and expanding pyridine networks are key. These findings transform SPAN optimization from empirical tuning to mechanism‑guided engineering and point the way towards sulfur loadings and energy densities competitive with state‑of‑the‑art Li‑ion cathodes.

25 ENERGY STORAGE

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

First Wall Design of a Tokamak Pilot Plant Using a Monte Carlo Model for 3-D Heat Flux Deposition

We present a method for calculating the heat fluxes deposited on nonaxisymmetric tokamak first wall components, allowing for a first-of-its-kind model for power handling in the tokamak far scrape-off layer (SOL). The DIV3D Monte Carlo model features strict global power conservation and can calculate the finite cross-field plasma transport into magnetically-shadowed regions, which is significant when dealing with meter-scale shadows introduced by components such as poloidal limiters or antennas. As a case study, we apply the DIV3D model to inform the distribution of first wall poloidal limiters in an ARC-class reactor device. We demonstrate that discrete protection limiters can efficiently reduce peak heat fluxes on recessed breeder wall components in the presence of significant far-SOL plasma fluxes. By varying the toroidal periodicity and radial standoff depth of the limiters, we demonstrate one of the tradeoffs that must be considered in first wall design: more limiters provide greater protection, but at the cost of reduced breeding performance. We also present the impact that radial misalignments between limiters would have on first wall power loading.

Monte Carlo methods

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Li Stripping Behavior of Anode‐Free Solid‐State Batteries Under Intermittent‐Current Discharge Conditions

Anode‐free manufacturing holds promise to enable high energy densities and lower Lithium (Li)‐metal solid‐state batteries (LMSSBs). Nevertheless, in contrast to thick Li foil (>50 µm), the stripping capacity of in situ‐formed Li (10–30 µm) is limited due to diminished creep flow, resulting in reduced accessible capacity. This study explores the correlation between stripping capacity and surface roughness of garnet Li 7 La 3 Zr 2 O 12 (LLZO) solid electrolyte. The results reveal that stripping capacity can be enhanced through the surface modification of solid electrolytes. Additionally, this study scrutinizes the stripping behavior of in situ Li under intermittent‐current discharge conditions, which are more relevant to the operational conditions of electric vehicles (EVs). It is demonstrated that, when compared to constant‐current stripping, intermittent‐current stripping effectively suppresses void formation and enhances the stripping capacity of in situ Li by 40%. It is considered that the intermittent current inhibits the accumulation of Li vacancies, thereby delaying the void formation. These findings provide valuable insights into the development of high‐performance anode‐free LMSSBs for EVs.

25 ENERGY STORAGE

Metal–Organic Framework-derived Atomic Metal Sites Promoting Sulfur Cathode for All-Solid-State Lithium–Sulfur Batteries

All-solid-state lithium–sulfur batteries (ASSLSBs) offer high energy density and intrinsic safety; however, they still face major challenges, including sluggish redox kinetics and poor sulfur utilization. Incorporating conductive materials into sulfur cathodes is an effective strategy to mitigate these limitations. Here, a highly conductive cobalt–nitrogen–doped carbon (Co–NC) derived from a metal–organic framework (MOF) is introduced to accelerate charge transfer and promote reversible sulfur conversion. Co−NC provides atomically dispersed Co–N sites and conductive carbon pathways that correlate with improved charge transfer, sulfur utilization, and rate capability. Co–NC@S cathode delivers 1499 mAh g–1 at C/20 with a high sulfur loading (5 mg cm–2) and retains 1292 mAh g–1 after five cycles (vs 443 mAh g–1 without Co–NC). Moreover, Co–NC derived ASSLSB achieves 903 mAh g–1 at 5C at 60 °C. This work provides a practical and effective approach to develop high energy, high-rate ASSLSBs.

25 ENERGY STORAGE