At least 37 records · Page 2

A Current Limiting Control Strategy for Single-Loop Droop-Controlled Grid-Forming Inverters Under Balanced and Unbalanced Faults

Existing studies reporting current limiting control strategies for grid-forming inverters primarily focus on grid-forming inverters that use a multi-loop control structure. This study reports a current limiting control for grid-forming inverters that uses a single-loop control structure. The proposed current limiting control was implemented at the pulse width modulation (PWM) control layer to guarantee a rapid response. Once an overcurrent caused by severe faults is detected, the proposed control strategy immediately blocks relevant insulated-gate bipolar transistors (IGBTs) using a hysteresis loop, ensuring that the overcurrent is limited within a few PWM cycles. After the fault is cleared, the inverter seamlessly transfers back to droop control mode to maintain stability. The current limiting control has been tested in a microgrid environment operating in the OPAL-RT platform. Study results show that the control strategy can effectively limit the overcurrent under both balanced and unbalanced faults and can maintain system transient stability after the fault is cleared.

Du, Wei↗

Limiting current in a collisional crossed-field gap

Crossed-field devices are often used in pulsed power and high-power microwave applications. Previous studies derived closed-form solutions for the limiting current of a vacuum crossed-field system, corresponding to the maximum permissible current for laminar flow, below and above the Hull cutoff B H for magnetic insulation. We extend these studies by introducing collision frequency into the electron force law as a friction term to derive the limiting current in a collisional crossed-field gap. The resulting solution recovers the vacuum crossed-field case in the limit of no collisions and the collisional space-charge limited current with general initial velocity for magnetic field B → 0. In the limit of infinite collisions, we obtain a crossed-field equivalent to the Mott–Gurney law for the maximum current permissible in a collisional, nonmagnetic diode. When the collision frequency ν is less than the electron cyclotron frequency Ω, increasing initial velocity makes the critical current nonmonotonic with increasing ν with the critical current higher at B = B H for ν = Ω. As for a misaligned crossed-field gap where a component of the magnetic field was introduced parallel to the electric field across the gap, magnetic insulation is eliminated and the discontinuity at B = B H for limiting current observed in a vacuum crossed-field gap vanishes. As B → ∞, the limiting current approaches a constant that depends on the initial velocity and the collision frequency.

Breen, Lorin I.↗

The Implications of Collisions on the Spatial Profile of Electric Potential and the Space-Charge-Limited Current

The space-charge-limited current (SCLC) in a vacuum diode is given by the Child-Langmuir law (CLL), whose electric potential ϕ(x) ∝ (x/D) 4/3 , where x is the spatial coordinate across the gap and D is the gap separation distance. For a collisional diode, SCLC is given by the Mott-Gurney law (MGL) and ϕ(x) ∝ (x/D) 3/2 . Here, we apply a capacitance argument for SCLC and use the transit time from a recent exact solution for collisional SCLC to show that ϕ(x) ∝ (x/D)ξ for a general collisional gap, where 4/3 ≤ ξ ≤ 3/2 . Furthermore, ξ is strictly a function of νT, where ν is the collision frequency and T is the electron transit time. Using this definition of ξ, we estimate the spatial dependence of the electron velocity and use the gap capacitance to derive an analytic equation for collisional SCLC that agrees within ~4.5% of the exact solution that requires solving parametrically through T. This analytic equation for general ξ asymptotically recovers the CLL as ν → 0 and the MGL as ν → ∞. As a result, matching these limits shows that ξ ≈ 1.40 and V ∝ D 2 ν 2 at the transition from a vacuum to a collisional diode for any device condition.

Anodes↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults: Preprint

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable bulk integration of renewable sources into the future power grid. However, the performance of GFM inverters during unbalanced faults remains under-explored. In this paper, a novel current-limiting method is proposed for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built-up in the stationary reference frame to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

Comparing measurement of limiting current in block copolymer electrolytes as a function of salt concentration with theoretical predictions

Optimizing electrolyte performance is crucial for the widespread adoption of electrochemical energy storage. We demonstrate that limiting current provides a robust criterion for determining the optimum electrolyte. Experiments were conducted on rigid block copolymer electrolytes comprising mixtures of polystyrene-block-poly(ethylene oxide) copolymer (SEO) and lithium bis(trifluoromethanesulfonyl) imide salt (LiTFSI) over a salt concentration range from r av = 0.04 to r av = 0.20 (r av is the molar ratio of lithium ions to ethylene oxide). Here we show that the maximum limiting current density is 4.3 mA cm –2 at r av = 0.12. The dependence of limiting current on salt concentration is in good agreement with predictions from Newman's concentrated solution theory with no adjustable parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of defect annealing in neutron-irradiated silicon by space-charge-limited current.

Use of space-charge-limited current (SCLC) to observe defect annealing in neutron-irradiated silicon. From the observation of the trap-filled-limit voltage a deep-trap concentration in the irradiated unannealed crystals is found to be at least 1.4 x 10 to the 12th power per cu cm. Shallow traps are also observed. This deep-trap concentration decreases with anneal temperature up to 200 C, above which SCLC can no longer be observed. There is evidence that at least some of this decrease is due to the conversion of the deep traps to shallow traps.

Magee, T. J.↗

Moderate pH changes alter the fluxes, selectivities and limiting currents in ion transport through polyelectrolyte multilayers deposited on membranes

Layer-by-layer (LBL) polyelectrolyte coatings on membranes are attractive for their high selectivities between monovalent and divalent ions. However, deposition of poly(4-styrenesulfonate) (PSS)/protonated poly(allylamine) (PAH) films on ion-exchange membranes leads to low ion fluxes that restrict productivity or current efficiency. This study shows that increasing the solution pH from 6.5 to 8.3 enhances cation fluxes and limiting currents through (PAH/PSS) 5 PAH-coated cation-exchange membranes while still achieving order of magnitude selectivity increases compared to bare membranes. In Donnan dialysis through (PAH/PSS) 5 PAH-coated Nafion, at pH 8.3 the K + /Mg 2+ selectivity is 100, and the K + flux is 22 times that at pH 6.5. Moreover, at the higher pH the electrodialysis limiting current through these membranes increases ~5-fold. This enables electrodialysis separation of K + and Mg 2+ with a current efficiency around 0.75, a selectivity of 18, and 50% K + recovery from the source phase. Transmembrane potential measurements and increases in Cl - /SO 4 2- selectivities (from 9.5 at pH 6.5 to ~70 at pH 8.3) for porous alumina membranes coated with (PSS/PAH) 5 PSS films suggest that the coating becomes cation-permselective at higher pH. Increased cation transference numbers in polyelectrolyte coatings likely lead to the enhanced limiting currents for coated Nafion at higher pH. Lastly, (PAH/PSS) 5 PAH-coated Nafion shows a Li + /Mg 2+ Donnan dialysis selectivity >700 at neutral pH and a selectivity of 10 at pH 8.3. However, the Li + flux is 6 times greater at pH 8.3, which might make operation at the higher pH desirable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation for the fault current limiting operation of REBCO CORC superconducting cables with different core materials

With high power density and low loss, CORC superconducting cables composed of RE- Ba 2 Cu 3 O 7–δ (REBCO) coated conductors are of great interest for power transmission applications. They can also effectively be designed to serve as fault current limiters, thanks to their sharp superconducting-to-normal transition. Coupled electromagnetic-thermal finite element (FE) simulations implemented in COMSOL Multiphysics were developed and validated against the published results for the fault current limiting performance of two CORC cables of REBCO coasted conductors wound on either copper or stainless steel cores. For improved accuracy, temperature dependencies of electrical and thermal properties of all component materials were considered in the simulations. The simulations were performed in the cross-sections of the cables for every individual layer of each REBCO tape to deliver comprehensive understanding of evolution of the current distribution and temperature rise in those layers. Furthermore, the studies can suggest approaches to optimize cable design for fault current limiting (FCL) applications by assessing the role of individual components. In the paper, possible computational errors, challenges and improvements are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Universal Relationship between Limiting Current and Electrochemical Transport Properties in Malonate-Based Polymer Electrolytes

There is considerable interest in developing high-performance electrolytes for rechargeable lithium batteries. For practical applications, the electrolyte must support large dc currents. However, the parameters most often reported in the literature, conductivity, κ, and current fraction, ρ + , reflect ion transport in the limit of infinitesimal currents. In this limit, the efficacy of an electrolyte is given by the product κρ + . The limiting current density, i lim , is the maximum current density that can be applied across an electrolyte; the cell voltage diverges if the applied current density exceeds ilim. This parameter reflects ion transport in the limit of large dc currents and is therefore of practical interest. It would therefore be convenient if i lim could be predicted from measurements of κρ + . In order to explore this possibility, we studied six malonate-based polymers and PEO at a fixed salt concentration (r = 0.08) and temperature (90°C) using symmetric cells with planar electrodes. Unfortunately, there is no correlation between ilim and κρ + . When the applied current density, i, is less than ilim, the cell voltage approaches a stable plateau, ϕ plateau . Here, we found a linear dependence between i and thickness-normalized plateau potential, ϕ plateau L –1 , irrespective of the magnitude of the applied current. In all seven polymer electrolytes, we found a linear correlation between ilim and the slopes of these lines, σ. In other words, measurements of σ can be used to predict the limiting current.

Jana, Rounak [Lawrence Berkeley National Laborator↗

A Methodology for the Analysis of Water Oxidation Electrocatalysts in the Absence of Limiting Current that Avoids the Pitfalls of Existing Methods

Water oxidation is an important reaction studied as a way to generate electrons from water, to promote water splitting and the formation of green hydrogen. When using electrodes to drive homogeneous water oxidation catalysis, cyclic voltammograms are analyzed to provide catalytic rate constants. There are two main methods, foot-of-the-wave analysis (FOWA) and limiting current analysis. FOWA relies on approximations inherent to analyzing water oxidation catalysis, such as determining the formal potential of the catalytic intermediate, E 0 cat . Limiting current methods are the optimal way to analyze catalyst performance but rely on observable limiting current, which is virtually never seen in water oxidation. To avoid those issues, a method is proposed for analyzing nonideal cyclic voltammetry waveshapes in water oxidation: by analyzing rate data across a large range of potentials, an optimal potential, E 0 cat , can be obtained, where catalytic current, i cat , is nearly independent of scan rate and has a linear dependency on buffer concentration. Here, the method is applied to four homogeneous water oxidation catalysts with prior extensive electrochemical elucidation, all of which lack an ideal, purely kinetic waveshape in cyclic voltammetry. Application of the method avoids the biases of the other methods cited for the kinetic analyses of water oxidation catalysts.

14 SOLAR ENERGY↗

Electron trapping in neutron-irradiated silicon studied by space-charge-limited current.

The trapping and detrapping of electrons is studied through measurements of space-charge-limited current in the temperature range of 77 to 293 K in high-purity silicon after irradiation with 14-MeV neutrons. A model is developed which describes most of the results quantitatively and self-consistently, including dc characteristics. Two distinct trap levels exist: the fast levels lie at 0.14 (plus or minus 0.005) eV below the conduction band, and the slow levels lie at 0.47 (plus or minus 0.01) eV below the conduction band. At 77 K, injected free electrons are initially captured by the fast 0.14-eV traps and then sink into the deep 0.47-eV traps, predominantly without being reemitted into the band. Above approximately 110 K, the detrapping rate from the shallow traps becomes so fast that the deep traps dominate. The results also offer a direct verification of the simple model of space-charge-limited current dominated by shallow and deep traps.

Quat, V. T.↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Current-limiting voltage regulator

Voltage regulator, which operates within preset current limits, acts as a circuit breaker to prevent overload failure, and automatically resets when the overload is removed. The power dissipated in the series transistor of the circuit is constant from normal load to short circuit condition.

Cleveland, E. F.↗