Search NASASearch

SEARCH · Search NASA

Results for “electric power system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,399 records · Page 2

International Space Station Lithium-Ion Battery Start-Up

International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.

Lithium-Ion

Preliminary Evaluation of Joint Electricity-Hydrogen Concept of Operations

An initial thermal power dispatch (TPD) concept of operations was evaluated that couples a nuclear power plant to a nearby hydrogen production plant. GSE Systems’ generic pressurized water reactor full-scope simulator was modified with a TPD model comprised of a thermal power extraction and delivery system. A prototype human-system interface (HSI) was developed to interact with the TPD model and allow participants to execute the basic operating scenarios for normal operations. Four retired operators performed the evaluation, and due to COVID-19 travel restrictions, the original in-person experimental design was restructured to support a remote participator evaluation using a web meeting platform. Data from operator feedback, observations from the research team, and quantitative survey responses revealed that the initial TPD concept of operations is feasible. The operators were comfortable with the engineered system and HSI and could manage it without adverse impacts to reactor power, plant safety, or equipment. Findings are discussed in terms of both the TPD system design and HSI performance.

human factors

Electrodynamic Tethers. 1: Power Generator in LEO. 2: Thrust for Propulsion and Power Storage

An electrodynamic tether consists of a long insulated wire in space whose orbital motion cuts across lines of magnetic flux to produce an induce voltage that in typical low orbits averages about 200 v/km. Such a system should be capable of generating substantial electrical power, at the expense of IXB drag acting on its orbital energy. If a reverse current is driven against the induced voltage, the system should act as a motor producing IXB thrust. A reference system was designed, capable of generating 20 KW of power into an electrical load located anywhere along the wire at the expense of 2.6N (20,000 J/sec) drag on the wire. In an ideal system, the conversion between mechanical and electrical energy would reach 100% efficiency. In the actual system part of the 20 KW is lost to internal resistance of the wire, plasma and ionosphere, while the drag force is increased by residual air drag. The 20 KW PMG system as designed is estimated to provide 18.7 KW net power to the load at total drag loss of 20.4 KJ/sec, or an overall efficiency of 92%. Similar systems using heavier wire appear capable of producing power levels in excess of 1 Megawatt at voltages of 2-4 KV, with conversion efficiency between mechanical and electrical power better than 95%. The hollow cathode based system should be readily reversible from generator to motor operation by driving a reverse current using onboard power.

James E Mccoy

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

Battery and Power Systems Designed by NASA

The engineering team in the Propulsion and Power Division designs, develops, tests and evaluates electric power and safe battery system solutions.

Martin Martinez

A Parametric Battery Model for the Conceptual Design of Electric Aircraft

Electric aircraft conceptual designs usually have an assumed specific power and specific energy for the aircraft’s energy storage system that dictates the total capacity and the peak power available. The specific energy and power are inherently linked to the state-of-charge and discharge rate from which they were derived; therefore, they will not directly correspond to the diverse circumstances encountered in various aircraft missions and flight segments. These parameters turn the battery system into a black box, disregard potential electrical restrictions, and disallow the aircraft and battery to be optimized as a system. Peering into this box, this study highlights the importance of incorporating a parametric battery model into the conceptual design workflow by splitting high-level terms such as power into voltage and current and investigating their variability during the discharge process. Through the modeling of these more detailed parameters, this methodology shows the feasibility of using low states-of-charge for contingency operations, including the end of the reserve mission, expanding the amount of usable capacity for electric aircraft. Stark differences in aircraft capabilities can arise between varying fidelity battery models due to late-mission, high-power flight operations. This parametric battery model effectively captures these differences by evaluating the limitations that arise within the individual battery cells and the aircraft powertrain. This paper shows that the unusable charge of a battery is set by the balked landing power requirement and can realistically range from 5% to 44% based on assumptions. This sets the analog to unusable fuel capacity in aircraft with liquid fuel systems. Needing only aircraft- and mission-level inputs and only seconds of run time, this model is a prime fit for the fast, accurate exploration of the electric aircraft conceptual design space.

Battery

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power

Smart Charging of Fleet and Personal Electric Vehicles through Joint Vehicle-to-Grid Optimization

As electric vehicle (EV) adoption accelerates, vehicle-to-grid (V2G) strategies offer advantages over unmanaged charging (V0G) by enhancing grid stability, reducing fleet operation costs, and supporting integration of variable generation resources. This research develops a day-ahead optimization framework linked with agent-based simulations to evaluate coordinated V2G participation by fleet and personal EVs under 5 energy-pricing settings in Austin, Texas. Three scenarios (V0G, fleet-only V2G, and joint-V2G) are examined, considering real-time price and grid profiles, health-damage costs, and operational constraints for both fleet and personal EVs. Results show how V2G scenarios shift fleet EV charging to mid-day while enabling strategic battery-discharge during evening peaks, mitigating grid stress and lowering EV energy costs. V2G delivers close to 80% energy-cost savings for a 2000-EV fleet in Austin on grid-stressed days, with 55% lower charging pollutant outputs. Joint-V2G amplifies system-level benefits by complementing fleet discharge, but smart-charging equipment costs can offset those benefits.

Electric vehicle

Electric Propulsion Orbital Platform

This paper describes the Electric Propulsion Orbital Platform (EPOP), of which the primary objective is to provide an instrumented platform for testing electric propulsion devices in space. It is anticipated that the first flight, EPOP-1, will take place on the Shuttle-deployed Wake Shield Facility in 1996, and will be designed around a commercial 1.8 kW arcjet system which will be operated on gaseous hydrogen propellant. Specific subsystems are described, including the arcjet system, the propellant and power systems, and the diagnostics systems.

V. J. Friedly

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion

Power Optimal Control Allocation for Distributed Electric Propulsion in a Series/Parallel Hybrid Powertrain

This paper describes a thrust allocation scheme that minimizes power consumption in an electrified powertrain with Distributed Electric Propulsion. It takes advantage of an observation about component efficiency maps, that efficiency is often highest at high torque/high speed conditions. This optimal approach is demonstrated to satisfy total thrust and net yaw axis torque requirements, making it suitable for utilizing differential thrust for maneuvering.

electrified aircraft propulsion

Solar Array Automation Limitations

Significant progress in the automation of the spacecraft electrical power systems has been made within the past few years. This is especially important with the development of the space station and the increasing demand on the electrical power systems for future satellites. The key element of the spacecraft power system, the solar arrays which supply the power, will have to grow to supply many tens of kilowatts of power within the next twenty years. This growth will be accompanied by the problems associated with large distributed power systems. The growth of the arrays, the on-array management problems and potential solutions to array degradation or failure are discussed. Multilowatt arrays for unmanned spacecraft with comments on the implications of array degradation for manned spacecraft are discussed.

Terry M Trumble

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics