At least 37 records · Page 2

Compensating For Doppler Shift In Laser Instrumentation

Electronic tuning system continually adjusts frequency of tunable diode laser to compensate for Doppler shift caused by motion of transmitter or receiver containing laser. Doppler-shift-compensating system intended primarily for use in transmitter or receiver of laser remote-sensing or communication system to keep frequency of received signal within frequency range of narrow-band-pass filter. By use of narrow-band filter (instead of wide-band filter required in absence of Doppler compensation), signal-to-noise ratio of laser system increased. Thus, less-powerful transmitter usable.

Schwemmer, Geary K.↗

Interfacing LabVIEW With Instrumentation for Electronic Failure Analysis and Beyond

The Laboratory Virtual Instrumentation Engineering Workstation (LabVIEW) software is designed such that equipment and processes related to control systems can be operationally lined and controlled by the use of a computer. Various processes within the failure analysis laboratories of NASA's Kennedy Space Center (KSC) demonstrate the need for modernization and, in some cases, automation, using LabVIEW. An examination of procedures and practices with the Failure Analaysis Laboratory resulted in the conclusion that some device was necessary to elevate the potential users of LabVIEW to an operational level in minimum time. This paper outlines the process involved in creating a tutorial application to enable personnel to apply LabVIEW to their specific projects. Suggestions for furthering the extent to which LabVIEW is used are provided in the areas of data acquisition and process control.

Buchanan, Randy K.↗

An instrument employing electronic counters and an emulsion chamber for studying heavy cosmic ray interactions (JACEE-3)

A JACEE-3 instrument was flown on a balloon in June 1982 for 6.1 sq m sr hr exposure at an average atmospheric depth of 5 gm/sq cm in order to study the cosmic ray spectra, composition, and interactions above 1 TeV. The nucleus-nucleus interactions were studied above 20 GeV/amu from z = 6 to z = 26. The electronic counters contained gas Cerenkov structures with a 1.0-cm thick lead glass and a 1.27-cm thick Teflon radiator. A comparison to the instrument prototype is made. Based on the electronic counter event data, the finding efficiency of the hodoscope is noted to be near 100 percent for z greater than or equal to 22. A comparison is made between the hodoscope-predicted position and track found at P3 in an emulsion chamber.

Austin, R. W.↗

An electromagnetic/electrostatic dual cathode system for electron beam instruments

A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

Bradley, J. G.↗

MUSTANG: A Workhorse for NASA Spaceflight Avionics

The Modular Unified Space Technology Avionics for Next Generation (MUSTANG) is a small integrated Avionics system including Command and Data Handling (C&DH), Power System Electronics (PSE), Attitude Control System Interfaces (ACS), and Propulsion Electronics. The MUSTANG Avionics Architecture is built upon many years of knowledge capture and lessons learned at the Goddard Space Flight Center. With a motivation towards modularity and keeping board redesign costs to a minimum, MUSTANG offers flexibility in features with a backplane-less design and allows the user to choose the options (cards) needed for their system. It incorporates a distributed power system that provides secondary power to all its subcomponents reducing the number of primary services needed for an Avionics. MUSTANG can be integrated into one system or divided into several smaller components. MUSTANG supports redundancy and cross-strap ability for a more robust and reliable Avionics system. A variation of MUSTANG exists for Instrument Electronics called iMUSTANG and allows the user to select functionality applicable to the instrument electronics. MUSTANG is not meant to replace Avionics for all spacecraft. There are limitations due to its relatively compact size, but the MUSTANG design has proven broadly applicable on many spacecraft and instrument bus avionics architectures.

MUSTANG↗

Electronic test instrument generates extremely small current signals

Generator produces dynamic test signals in the range from 0.0001 and 10 to the minus 12th power amperes. It involves an extension of the technique of applying a triangular voltage waveform to a small capacitor to obtain a square-wave output current. The effects of stray capacitance are minimized by appropriate shielding.

Brookshier, W. K.↗

Electronic test instrumentation and techniques: A compilation

The uses of test equipment and techniques used in space research and development programs are discussed. Modifications and adaptations to enlarge the scope of usefulness or divert the basic uses to alternate applications are analyzed. The items of equipment which have been of benefit to professional personnel in the enlargement and improvement of quality control capabilities are identified. Items which have been simplified or made more accurate in conducting measurements are described.

Source record↗

Instrument For Simulation Of Piezoelectric Transducers

Electronic instrument designed to simulate dynamic output of integrated-circuit piezoelectric acceleration or pressure transducer. Operates in conjunction with external signal-conditioning circuit, generating square-wave signal of known amplitude for use in calibrating signal-conditioning circuit. Instrument also useful as special-purpose square-wave generator in other applications.

Mcnichol, Randal S.↗

Magnetic field-aligned electron distributions in the dayside cusp

Observations of low-energy electron fluxes made over a 6 year period with the photoelectron spectrometer on the AE-C and AE-D satellite are used to investigate electron pitch angles in the low altitude cusp. A 16 point energy spectrum from 2 to 500 eV was obtained at every .25 s, and the location of the cusp was verified by the presence of protons detected by the low-energy electron instrument. Isotropic fluxes of precipitating electrons with Maxwellian energy spectra were observed in the low-altitude cusp, and the presence of low-energy electrons with pitch angles less than 15 deg was determined streaming into the cusp ionosphere. The energies of the streaming electrons sometimes appeared as a peak superimposed on the normal cusp Maxwellian background of isotropic electrons, and it is concluded that the energies and pitch angle distributions of the precipitating electrons may explain the enhancements of auroral emissions and discrete arcs.

Zanetti, L. J.↗

A portable absorbed dose measuring instrument with gamma discrimination

The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

Quam, W. M.↗

Electrically Conductive Anodized Aluminum Surfaces

Anodized aluminum components can be treated to make them sufficiently electrically conductive to suppress discharges of static electricity. The treatment was conceived as a means of preventing static electric discharges on exterior satin-anodized aluminum (SAA) surfaces of spacecraft without adversely affecting the thermal-control/optical properties of the SAA and without need to apply electrically conductive paints, which eventually peel off in the harsh environment of outer space. The treatment can also be used to impart electrical conductivity to anodized housings of computers, medical electronic instruments, telephoneexchange equipment, and other terrestrial electronic equipment vulnerable to electrostatic discharge. The electrical resistivity of a typical anodized aluminum surface layer lies between 10(exp 11) and 10(exp 13) Omega-cm. To suppress electrostatic discharge, it is necessary to reduce the electrical resistivity significantly - preferably to < or = 10(exp 9) Omega-cm. The present treatment does this. The treatment is a direct electrodeposition process in which the outer anodized surface becomes covered and the pores in the surface filled with a transparent, electrically conductive metal oxide nanocomposite. Filling the pores with the nanocomposite reduces the transverse electrical resistivity and, in the original intended outer-space application, the exterior covering portion of the nanocomposite would afford the requisite electrical contact with the outer-space plasma. The electrical resistivity of the nanocomposite can be tailored to a value between 10(exp 7) and 10(exp 12) Omega-cm. Unlike electrically conductive paint, the nanocomposite becomes an integral part of the anodized aluminum substrate, without need for adhesive bonding material and without risk of subsequent peeling. The electrodeposition process is compatible with commercial anodizing production lines. At present, the electronics industry uses expensive, exotic, electrostaticdischarge- suppressing finishes: examples include silver impregnated anodized, black electroless nickel, black chrome, and black copper. In comparison with these competing finishes, the present nanocomposite finishes are expected to cost 50 to 20 percent less and to last longer.

Nguyen, Trung Hung↗

COSTEP: A comprehensive suprathermal and energetic particle analyzer for SOHO

The group of instruments involved in the COSTEP (comprehensive suprathermal and energetic particle analyzer) project are described. Three sensors, the LION (low energy ion and electron) instrument, the MEICA (medium energy ion composition analyzer) and the EPHIN (electron proton helium instrument) are described. They are designed to analyze particle emissions from the sun over a wide range of species (electrons through iron) and energies (60 KeV/particle to 500 MeV/nucleon). The data collected is used in studying solar and space plasma physics.

Kunow, Horst↗

Investigation of Space Based Solid State Coherent Lidar

This report describes the work performed over the period of October 1, 1997 through March 31, 2001. Under this contract, UAH/CAO participated in defining and designing the SPAce Readiness Coherent Lidar Experiment (SPARCLE) mission, and developed the instrument's optical subsystem. This work was performed in collaborative fashion with NASA/MSFC engineers at both UAH/CAO and NASA/MSFC facilities. Earlier work by the UAH/CAO had produced a preliminary top-level system design for the Shuttle lidar instrument meeting the proposed mission performance requirements and the Space Shuttle Hitchhiker canister volume constraints. The UAH/CAO system design efforts had concentrated on the optical and mechanical designs of the instrument. The instrument electronics were also addressed, and the major electronic components and their interfaces defined. The instrument design concept was mainly based on the state of the transmitter and local oscillator laser development at NASA Langley Research Center and Jet Propulsion Laboratory, and utilized several lidar-related technologies that were either developed or evaluated by the NASA/MSFC and UAH/CAO scientists. UAH/CAO has developed a comprehensive coherent lidar numerical model capable of analyzing the performance of different instrument and mission concepts. This model uses the instrument configuration, atmospheric conditions and current velocity estimation theory to provide prediction of instrument performance during different phases of operation. This model can also optimize the design parameters of the instrument.

Amzajerdian, Farzin↗

Fuse protects circuit from voltage and current overloads

Low-melting resistor connected in series with the load protects the circuit against current overloads. It protects test subjects and patients being monitored by electronic instrumentation from inadvertant overloads of current, and sensitive electronic equipment against high-voltage damage.

Casey, L. O.↗

Optical scanning tests of complex CMOS microcircuits

The new test method was based on the use of a raster-scanned optical stimulus in combination with special electrical test procedures. The raster-scanned optical stimulus was provided by an optical spot scanner, an instrument that combines a scanning optical microscope with electronic instrumentation to process and display the electric photoresponse signal induced in a device that is being tested.

Levy, M. E.↗