Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Laboratory molecular spectroscopy

The precision required in making spectroscopic measurements is discussed. Remarks are directed specifically to vibration-rotation spectra rather than continuum absorptions. The ultimate precision that is required for line positions is related to the width of the lines which may be no narrower than the Doppler width. The spectroscopic methods considered are those which are of the most general value to the astronomers; those which acquire and can handle large volumes of spectra in digital form, or in a form which is compatible with computer analysis, and in a form which is at least internally consistent. The use of dye laser, grating instruments, and the most versatile instrument for laboratory spectroscopy, the Fourier transform spectrometer is discussed.

Margolis, J.↗

A review of acetylene, ethylene and ethane molecular spectroscopy for planetary applications

Spectroscopic work in acetylene, ethylene and ethane, are of particular interest since the Voyager IRIS observations of Jupiter. Acetylene and ethane but not ethylene were observed in the Jovian spectrum. Two fundamental bands of the observed gases are used to determine the spatial distribution of these hydrocarbons on Jupiter and to illuminate the photochemistry of these species. The 100 to 1000 cm region is discussed and selected examples of current laboratory work are given.

Maguire, W. C.↗

Molecular Spectroscopy by Ab Initio Methods

Due to recent advances in methods and computers, the accuracy of ab calculations has reached a point where these methods can be used to provide accurate spectroscopic constants for small molecules; this will be illustrated with several examples. We will show how ab initio calculations where used to identify the Hermann infrared system in N2 and two band systems in CO. The identification of all three of these band systems relied on very accurate calculations of quintet states. The analysis of the infrared spectra of cool stars requires knowledge of the intensity of vibrational transitions in SiO for high nu and J levels. While experiment can supply very accurate dipole moments for nu = 0 to 3, this is insufficient to construct a global dipole moment function. We show how theory, combined by the experiment, can be used to generate the line intensities up to nu = 40 and J = 250. The spectroscopy of transition metal containing systems is very difficult for both theory and experiment. We will discuss the identification of the ground state of Ti2 and the spectroscopy of AlCu as examples of how theory can contribute to the understanding of these complex systems.

Bauschlicher, Charles W., Jr.↗

Molecular velocimetry using stimulated Raman spectroscopy

Molecular flow velocity of N2 was measured in a supersonic wind tunnel using inverse Raman spectroscopy. This technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counter-propagating (backward scattering). A retrometer system is employed to yield a vibration-free optical configuration which has the additional advantage of obtaining both the forward and backward scattered spectra simultaneously. The linebreadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the concept was performed in a supersonic wind tunnel and included: (1) measurements over the Mach number range 2.50 to 4.63; (2) static pressure measurements (at Mach 2.50) corresponding to a Reynolds number per foot range of 1 to 5 x 10 to the 6th power; and (3) measurements behind the shock wave of a flat plate model.

Exton, R. J.↗

Double-modulation spectroscopy of molecular ions - Eliminating the background in velocity-modulation spectroscopy

Velocity-modulation spectroscopy is an established technique for performing laser absorption spectroscopy of molecular ions in a discharge. However, such experiments are often plagued by a coherent background signal arising from emission from the discharge or from electronic pickup. Fluctuations in the background can obscure the desired signal. A simple technique using amplitude modulation of the laser and two lock-in amplifiers in series to detect the signal is demonstrated. The background and background fluctuations are thereby eliminated, facilitating the detection of molecular ions.

Lan, Guang↗

Photoelectron spectroscopy in molecular physical chemistry

Photoelectron spectroscopy has long been a powerful method in the toolbox of experimental physical chemistry and molecular physics. Recent improvements in coincidence methods, charged-particle imaging, and electron energy resolution have greatly expanded the variety of environments in which photoelectron spectroscopy can be applied, as well as the range of questions that can now be addressed. In this Perspectives Article, we focus on selected recent studies that highlight these advances and research areas. Furthermore, the topics include reactive intermediates and new thermochemical data, high-resolution comparisons of experiment and theory using methods based on pulsed-field ionisation (PFI), and the application of photoelectron spectroscopy as an analytical tool to monitor chemical reactions in complex environments, like model flames, catalytic or high-temperature reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory diode laser spectroscopy in molecular planetary astronomy

Infrared spectroscopy of planetary atmospheres is performed at high spectral resolution comparable to that in the laboratory. This requires that laboratory spectroscopy use the highest resolution and the most accurate techniques. Tunable diode laser spectroscopy can supply many of the spectroscopic parameters needed by astronomers. In particular, line positions, line strengths, and collisional line widths are measured with diode lasers, and these are often among the best values available. Diode laser spectra are complimentary to lower resolution, broader-coverage Fourier transform spectra. Certain procedures must be adopted, however, when using diode lasers, for determining their output characteristics and for calibrating each spectrum against quality references.

Jennings, D. E.↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Computational approaches to model X-ray photon correlation spectroscopy from molecular dynamics

X-ray photon correlation spectroscopy (XPCS) allows for the resolution of dynamic processes within a material across a wide range of length and time scales. X-ray speckle visibility spectroscopy (XSVS) is a related method that uses a single diffraction pattern to probe ultrafast dynamics. Interpretation of the XPCS and XSVS data in terms of underlying physical processes is necessary to establish the connection between the macroscopic responses and the microstructural dynamics. To aid the interpretation of the XPCS and XSVS data, we present a computational framework to model these experiments by computing the X-ray scattering intensity directly from the atomic positions obtained from molecular dynamics simulations. We compare the efficiency and accuracy of two alternative computational methods: the direct method computing the intensity at each diffraction vector separately, and a method based on fast Fourier transform that computes the intensities at all diffraction vectors at once. Furthermore, the computed X-ray speckle patterns capture the density fluctuations over a range of length and time scales and are shown to reproduce the known properties and relations of experimental XPCS and XSVS for liquids.

36 MATERIALS SCIENCE↗

Perturbative theoretical model of electronic transient circular dichroism spectroscopy of molecular aggregates

A chiral analog of transient absorption spectroscopy, transient circular dichroism (TCD) spectroscopy is an emerging time-resolved method. Both spectroscopic methods can probe the electronic transitions of a sample, and TCD is additionally sensitive to the dynamic aspects of chirality, such as those induced by molecular excitons. Here, we develop a theoretical description of TCD for electronic multi-level models in which the pump pulse is linearly polarized and probe pulse is alternately left- and right-circularly polarized. We derive effective response functions analogous to those often used to describe other four-wave mixing methods and then simulate and analyze TCD spectra for three representative multi-level electronic model systems. We elaborate on the presence and detection of the spectral signatures of electronic coherences.

77 NANOSCIENCE AND NANOTECHNOLOGY↗