Surface profilometer for examining grain-boundary grooves

Surface profilometer, consisting primarily of commercially available components, measures surface topographical features accurately and precisely. It shows improvement over the interferometric technique in measurement of grain-boundary grooves formed during annealing on nickel-oxide bicrystals.

Jech, R. E.↗

Laser Rangefinder and Remote Profilometer

Proposed laser rangefinder and profilometer operates with precision of about 1mm at ranges of up to 100m. With scanning optics, device could track objects or accurately measure shapes of objects in field of view. New microprocessor-controlled design uses variable-length fiber-optic delay line as distance reference. New rangefinding method used in vision systems for industrial robots.

Mclauchlan, J. M.↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in papers Yashchuk et al. (2007), Yashchuk et al. (2008) is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one-dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high performance of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two-dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the Micromap{trademark}-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

Defect Characterization Through Automated Laser Track Trace Identification in SLM Processes Using Laser Profilometer Data

This paper presents recent developments in statistical image processing to demonstrate feasibility of layer-by-layer nondestructive inspection for selective laser melting (SLM) of metallic parts. A matrix of 10 mm × 10 mm stainless 316 squares was deposited with the first row consisting of just the sintered surface, Row 2 a single layer, Row 3 with 2 layers and so on. These layers were scanned to emulate the layer-by-layer collection of top surface geometry using a laser sensor. The resultant data were utilized to generate ISO 25718 roughness parameters and subsequently to perform track identification. This calculation consisted of two salient steps: (1) computing the gradients of surface roughness, which vanish at the peaks and pits, and (2) extracting the scanning direction by taking Hough transform of the geometry. This algorithm was repeated for all layers, and the alignment of the roughness with the rotating scan was observed to be persistent for all layers. Correlation between surface properties obtained along various scan directions and defect probability is explored.

36 MATERIALS SCIENCE↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical profilometer

Device, consisting of optical scanning subsystem, two light detectors with associated amolifiers, analog divider, and adjustable nonlinear function generator, directly determines surface area, absolute depth, and point-to-point distance of three-dimensional object without physical contact with surface under observation.

Burcher, E. E.↗

A laser profilometer for digital terrain mapping

A preliminary design of a space-based decimeter accuracy ranging instrument is described along with the ranging subsystem, the pointing subsystem, and attitude reference. The measurement capabilities including ranging accuracy, the signal-to-noise ratio for water, ice, and solid Earth, footprint size, and atmospheric effects are defined and the overall system with its advantages and disadvantages are summarized.

Rubin, B.↗

Weld-Bead Profilometer Rejects Optical Noise

Optoelectronic sensor measures profile of weld seam or weld bead along line perpendicular to seam. Illuminated by fan of laser light. Image of line digitized and converted to profile of height or depth versus transverse position. Intended to be part of highly automated welding system, used in automatic tracking of seam or automatic profiling of weld bead for immediate evaluation and assurance of quality during welding process. Requires little maintenance other than cleaning glass windows protecting laser and camera.

Kennedy, Larry Z.↗

Interaction of atomic oxygen with thin film and bulk copper: An XPS, AES, XRD, and profilometer study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed primarily to study degradation of material surfaces due to low earth orbital (LEO) atmospheric oxygen. The experiment contained 128 one inch circular samples: metals, polymers, carbons, and semiconductors. Among metal samples, copper has shown some interesting new results. Two types of copper samples, a film sputter coated on fused silica and a bulk piece of OFHC copper, were characterized employing a variety of techniques such as X-ray and Auger electron spectroscopies, X-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to characterize the presence of Cu2O and CuO in addition to Cu Auger LMM lines. These results are supported by our recent X-ray diffraction studies which clearly establish the presence of Cu oxides which we were unable to prove in our earlier work. Profilometry showed an increase in thickness of the film sample where exposed to 106.7 +/- 0.5 nm from an initial thickness of 74.2 +/- 1.1 nm. Further studies with SEM and ellipsometry are underway.

Raikar, Genesh N.↗

Automated Surface Profilometer

Computer-controlled system saves time and labor. Electromechanical scanning system automatically measures deviation of sheets and plates from flatness. Quickly measures surface profile and detects bumps, bulges, and indentations as small as 0.001 in. in height or depth. X-y table moves specimen to programmed locations under digital linear variable differential transformer (LVDT) while computer records surface-height readings of LVDT. Resulting graphical display shows surface contour.

Chern, E. James↗

Specification of EBR-II Laser Profilometry Data

All laser profilometry data stored in FIPD were originally measured using the element laser profilometer system in HFEF/N. The irradiated fuel elements or pins were scanned by a laser beam to measure the outer diameter with position mapping of the spacer wire. The normal operation and data collection were performed automatically with HFEF/N Data Acquisition and Process Control System (DAPCS). With the digital control system, measured laser profilometry data were recorded in digital form on magnetic tapes, different from the analog contact profilometry data recorded by strip-chart record sheets. Two documents contained most of the important details about laser profilometry measurements. The first one is the operational manual of the laser profilometer (title: Element laser profilometer (ELP) operation and maintenance manual, HFEF/N OMM 4329, DOC. NO. W0171-0149-ES-01). This manual provides: (1) description of laser profilometer including the functions of each component (transceiver, retroreflector, clamping guide, shielding enclosure, electronic controller, etc.); (2) step-by-step guidance for calibrations, operations and measurements; and (3) maintenance procedures and other details of the element laser profilometer. Since first issued on 12/1/1986, several revisions/changes of the manual were developed to update the measurement accuracies and other factors for the laser profilometer system. The second document is a publicly accessible conference article titled “the element laser profilometer system in HFEF/N.” This article summarizes important functions and parameters of the laser profilometer. The range of measurements and the uncertainties reported in the article were consistent with the values reported in the operational manual.

42 ENGINEERING↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.