NADH oxidase activity (NOX) and enlargement of HeLa cells oscillate with two different temperature-compensated period lengths of 22 and 24 minutes corresponding to different NOX forms

NOX proteins are cell surface-associated and growth-related hydroquinone (NADH) oxidases with protein disulfide-thiol interchange activity. A defining characteristic of NOX proteins is that the two enzymatic activities alternate to generate a regular period length of about 24 min. HeLa cells exhibit at least two forms of NOX. One is tumor-associated (tNOX) and is inhibited by putative quinone site inhibitors (e.g., capsaicin or the antitumor sulfonylurea, LY181984). Another is constitutive (CNOX) and refractory to inhibition. The periodic alternation of activities and drug sensitivity of the NADH oxidase activity observed with intact HeLa cells was retained in isolated plasma membranes and with the solubilized and partially purified enzyme. At least two activities were present. One had a period length of 24 min and the other had a period length of 22 min. The lengths of both the 22 and the 24 min periods were temperature compensated (approximately the same when measured at 17, 27 or 37 degrees C) whereas the rate of NADH oxidation approximately doubled with each 10 degrees C rise in temperature. The rate of increase in cell area of HeLa cells when measured by video-enhanced light microscopy also exhibited a complex period of oscillations reflective of both 22 and 24 min period lengths. The findings demonstrate the presence of a novel oscillating NOX activity at the surface of cancer cells with a period length of 22 min in addition to the constitutive NOX of non-cancer cells and tissues with a period length of 24 min.

Non-NASA Center↗

Polymer microscopy

Detection of polyethylene single crystals deposited on reflecting substrate using incident light microscope

POLYETHYLENE↗

Structure and Dynamics of Interfaces: Drops and Films

We aim to acquire measurements of the structure and dynamics of certain liquid-fluid interfaces using an ensemble of techniques in collaboration: (1) Total internal reflection (TIR) Surface light scattering spectroscopy (SLSS), (2) Brewster angle microscopy (BAM), and (3) Drop-shape analysis. SLSS and BAM can be done on a shared interfacial footprint. Results using a 50-50 mixture of pentane-isohexane, which extends the range of NASA's Confined Vapor Bubble (CVB) experiment, yield surface tension results that differ from the expected Langmuir Fit. These results were confirmed using both the SLSS and drop-shape analysis approaches.

pentane-isohexane mixture↗

Electron and Light Microscopy Techniques Suitable for Studying Fatigue Damage in a Crystallized Glass Ceramic

The crystals of Pyroceram are randomly oriented and highly reflective so that standard microscopy techniques are not satisfactory for studying this material. Standard replicating procedures proved difficult to use. New microscopy techniques and procedures have therefore been developed. A method for locating, orienting, and identifying specific areas to be viewed with an electron microscope is described. This method not require any special equipment. Plastic replicas were found to be unsatisfactory because of their tendency to adhere to Pryoceram. This caused them to tear when released or resulted in artifacts. Preshadowed silicon monoxide replicas were satisfactory but required a releasing agent. A method of depositing the releasing agent is described. To polish specimens without evidence of fire-polishing, it was found necessary to use a vibratory polishing technique. Chrome oxide was used as the abrasive and either water or kerosene as the lubricant. Vibratory polishing is extremely slow, but surfaces so polished show no evidence of fire polishing, even when examined by electron microscopy. The most satisfactory etching process used for Pyroceram 9608 consisted of a primary etch of 5 milliliters of hydrochloric acid (concentrated), 5 milliliters of hydrogen fluoride (45 percent), and 45 milliliters of water, and a secondary etch with methyl alcohol replacing the water. Best results were obtained with total etching times from 25 to 30 seconds. Staining of the Pyroceram surface with a Sanford's marker was found to be an expedient way to reduce the glare of reflected light.

Harrell, Shelley↗

Understanding the Feasibility of MAB Phase Structures for Lunar Applications

During the ten-week internship, my work focused on synthesis, characterization, and tailoring the flowability of the MAB phase powders for improving the surface finish and decreasing porosity of 3D-printed MAB phase structures. My mentor for the project was Dr. Samuel Hocker from NASA Langley and my faculty advisor was Dr. Surojit Gupta from the University of North Dakota. I also collaborated with Daniel Trieff from the University of North Dakota in developing characterization paradigm of 3D printed samples. The microencapsulation was performed via novel solvent casting-based microencapsulation process pioneered in UND, wherein a polymer (PLA, PHA) was dissolved into dichloromethane and precipitated onto the surface of the MoAlB particles. Two 100mL samples of microencapsulated powder was outsourced to Particle Technology Labs for flowability testing along with a 100mL control sample to determine if microencapsulation is a valid method for improving the flowability. The microencapsulated powders were characterized using SEM, Differential Scanning Calorimetry, and optical microscopy. The SEM images showed no change between the pure and microencapsulated powders. The optical microscopy analysis indicated a reduction in reflectivity for the PLA microencapsulated powders as well as hydrophobic properties. Both results suggest that microencapsulation was successful as PLA is a hydrophobic polymer and the change in reflectivity could be a result of the light being dispersed through the polymer coating. A reflectivity analysis will be done to bring more perspective to these observations. If powder flowability is improved, then the project will move forward with testing the printability of the microencapsulated powders and characterizing the structures using the designed characterization protocol. We are waiting for the DSC results. The characterization protocol for the 3D-printed MAB structures included a visual inspection of the plates to rule out any samples that had spalled or delaminated, optical microscopy to document surface features, porosity, and decomposition, and cleaning of the plates using an ultrasonic bath in preparation for SEM, EDS, and profilometry analyses.

MAB Phase↗

Total Internal Reflection Tomography (TIRT) for Three-Dimensional Sub-Wavelength Imaging

We will present a novel new form of near-field microscopy known as total internal reflection tomography (TIRT), which allows for true three-dimensional sub-wavelength imaging. It is based on recent theoretical advances regarding the fundamental interaction of light with sub-wavelength structures, as well as stable algorithms for the near-field inverse problem. We will discuss its theoretical underpinnings, as well describe current efforts at the NASA Glenn Research Center to implement a TIRT system for biofluid research.

Fischer, David G.↗

Homogeneous condensation of gaseous mixtures of Si, Fe, O, N, and C in relative cosmic abundance and implications for astronomical condensation

The pressure versus temperature curves for homogeneous nucleation and condensation of two gaseous mixtures with nearly relative solar abundance of Si, Fe, O, N, and C in an excess of H were determined experimentally. Mixtures of CO, Fe(CO)5, H2, SiH4, and N2O in Ar were heated behind reflected shocks in a shock tube. The nucleation and condensation, which took place in the subsequent gas-dynamic expansion (cooling phase), was monitored by light scattering and turbidity. Grain morphologies and crystalline phases present in the condensates were determined by electron microscopy. These data cast doubt on the validity of both equilibrium and classical nucleation theoretical approaches to predict homogeneous condensation in a solar nebula or stellar atmosphere.

Stephens, J. R.↗

UV Shielding of Bacillus pumilus SAFR-032 Endospores by Martian Regolith Simulants

As exploration of the solar system advances with life detection missions on the horizon, the concern for planetary protection has grown considerably. When attempting to detect extraterrestrial life, the likelihood of false positives from terrestrial contamination must be minimized. The Exposing Microorganisms in the Stratosphere (E-MIST) balloon project aims to evaluate whether resilient terrestrial bacteria can survive stressors in a Mars-like environment. This is accomplished by sending Bacillus pumilus SAFR-032, an endospore-forming bacterial isolate from a spacecraft assembly facility, to the Earth's middle stratosphere (30-38 kilometers), where low temperature and pressure and high radiation and dryness conditions are similar to the surface of Mars. Previous ground and flight tests showed that the vast majority of SAFR-032 spores (99.99 percent) were inactivated by direct sunlight due to ultraviolet (UV) radiation. This observation led us to explore the role of dust shielding in changing microbial survivorship outcomes. To determine the dust particle distributions and density for potentially shielding microbes from UV radiation, samples of a Martian dust simulant were mixed with SAFR-032 spores. The dry heat sterilized simulant used was JSC MARS-1, weathered volcanic ash from Hawaii that displays many chemical and physical properties similar to the Martian soil as characterized by the Viking Lander 1, including reflectance spectrum, chemical composition, mineralogy, grain size, specific gravity, and magnetic properties. First, scanning electron microscopy was undertaken to visualize the aggregation of the spores with dust particles (i.e., shading effects), and samples of varying dust concentrations were subsequently irradiated with UVC light to test survivorship outcomes. After a relationship between dust concentration and spore survivorship was determined, a solar simulator capable of irradiating samples with a fuller UV spectrum (less than 280-400 nanometers) was used to perform a more robust middle stratosphere simulation. Taken together, we will use results from the ground-based irradiation studies to feed into experimental designs for the next E-MIST ultra-long duration polar balloon flight launched by NASA.

Stratosphere↗

Problems and possible solutions involved in hard target calibration of coherent Doppler lidar

The field of radiometry is surveyed with reference to coherent light, since the surfaces to be considered here are irradiated with coherent, polarized light. Definitions of some concepts are modified. In light of these modifications calibration problems are analyzed and solutions suggested. The most important task was to develop hard targets exhibiting minimal specular reflection (mirror-like and retroreflection) and following closely a Lambertian scattering curve. Bistable reflectometer experiments and integrating sphere measurements are used to physically characterize the targets. Optical and electron microscopy are used to physically characterize the targets. Since the BRDF matrix is not measured, this capability must be developed preferably for both bistatic and monostatic reflectometer measurements. The equipment is expensive and not yet developed. Calibration can be simplified if it can be proved that the BRDF matrix is diagonal for a diffuse scatterer.

Anderson, Richard↗

Soft x ray optics by pulsed laser deposition

A series of molybdenum thin film depositions by PLD (Pulsed Laser Deposition) have been carried out, seeking appropriate conditions for multilayer fabrication. Green (532 nm) and UV (355 nm) light pulses, in a wide range of fluences, were used. Relatively large fluences (in comparison with Si) are required to cause evaporation of molybdenum. The optical penetration depths and reflectivities for Mo at these two wavelengths are comparable, which means that results should be, and do appear to be similar for equal fluences. For all fluences above threshold used, a large number of incandescent particles is ejected by the target (either a standard Mo sputtering target or a Mo sheet were tried), together with the plasma plume. Most of these particles are clearly seen to bounce off the substrate. The films were observed with light microscopy using Nomarski and darkfield techniques. There is no evidence of large debris. Smooth films plus micron-sized droplets are usually seen. The concentration of these droplets embedded in the film appears not to vary strongly with the laser fluence employed. Additional characterization with SEM and XRD is under way.

Fernandez, Felix E.↗

Metrological and Spectral Characterization of the Aspera Flight Optics

Aspera is a NASA's Astrophysics Pioneers mission, led by the University of Arizona. The aim of this mission is to study the presence of hot gasses (T=10^5-10^6 K) in the circumgalactic medium (CGM) and how the flow of these gasses affects galactic formation. One key enabling technology in the Aspera optical system is the use of more efficient UV-reflective optical coatings particularly at around 103.2 nm where the O VI emission line is located . In order to meet radiometric effective area requirements, the Goddard Space Flight Center (GSFC) code 551 Optics Branch applied Al (aluminum) + eLiF (enhanced lithium fluoride) on these optics, where the Al+LiF is annealed at elevated temperature (~250˚C) after the deposition and thus providing an improved version of the Al+LiF used in FUSE . Furthermore, these optics are encapsulated with a thin film of atomic layer deposited MgF2 at the Jet Propulsion Laboratory for enhanced durability . The efficiency and durability of these coatings depends on the quality of the optical surface in terms of cleanliness and roughness. Roughness increases the scatter off the coating and reduces the specular reflectance, and surface contaminants can accommodate moisture and other contaminants, increase scattering, and are weak points in the coating that may affect adhesion and subsequently the longevity of these coatings. Extensive optical metrology is necessary to minimize and quantify the impact of surface roughness and contaminants on optical surfaces. In this proceeding we report the inspection procedure implemented for Aspera optics at GSFC, from initial receiving of the optics to post-coating. Inspection includes Atomic Force Microscopy (AFM), Scanning White Light Interferometry (SWILI), Dark Field Microscopy (DFM), Phase Shifting Interferometry (PSI), and Vacuum ultraviolet (VUV) spectroscopy. Combinations of these techniques are used to inspect flight optics at each of the following steps: i) as-received, pre-cleaning inspection, ii) pre-coating, post-cleaning inspection, and iii) post-coating inspection. The evolution of roughness and other surface inspections such as contaminants are compared between each step to quantify the effect each step has on the flight optics. The final far ultraviolet (FUV) spectral performance of witness samples coated with the flight optics are presented.

Far Ultraviolet (FUV)↗

Scanning electron acoustic microscopy of indentation-induced cracks and residual stresses in ceramics

The ability of scanning electron acoustic microscopy (SEAM) to characterize ceramic materials is assessed. SEAM images of Vickers indentations in SiC whisker-reinforced alumina clearly reveal not only the radial cracks, the length of which can be used to estimate the fracture toughness of the material, but also reveal strong contrast, interpreted as arising from the combined effects of lateral cracks and the residual stress field left in the SiC whisker-reinforced alumina by the indenter. The strong contrast is removed after the material is heat treated at 1000 C to relieve the residual stresses around the indentations. A comparison of these observations with SEAM and reflected polarized light observations of Vickers indentations in soda-lime glass both before and after heat treatment confirms the interpretation of the strong contrast.

Cantrell, John H.↗

Micrometeoroid Impacts and Optical Scatter in Space Environment

This paper discusses the results of an attempt to use laboratory test data and empirically derived models to quantify the degree of surface damage and associated light scattering that might be expected from hypervelocity particle impacts in space environment. Published descriptions of the interplanetary dust environment were used as the sources of particle mass, size, and velocity estimates. Micrometeoroid sizes are predicted to be predominantly in the mass range 10(exp -5) g or less, with most having diameters near 1 micrometer, but some larger than I20 micrometers, with velocities near 20 kilometers per second. In a laboratory test, latex ( p = 1.1. grams per cubic centimeter) and iron (7.9 grams per cubic centimeter) particles with diameters ranging from 0.75 micrometers to 1.60 micrometers and with velocities ranging from 2.0 kilometers per second to 18.5 kilometers per second, were shot at a Be substrate mirror that had a dielectric coated gold reflecting surface. Scanning electron and atomic force microscopy were used to measure crater dimensions that were then associated with particle impact energies. These data were then fitted to empirical models derived from solar cell and other spacecraft surface components returned from orbit, as well as studies of impact craters studied on glassy materials returned from the lunar surface, to establish a link between particle energy and impact crater dimension. From these data, an estimate of total expected damaged area was computed and this result produced an estimate of expected surface scatter from the modeled environment.

Heaney, James B.↗

Teflon FEP Analyzed After Retrieval From the Hubble Space Telescope

During the Hubble Space Telescope (HST) Second Servicing Mission, 6.8 years after the telescope was deployed in low Earth orbit, degradation of unsupported Teflon FEP (DuPont; fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer (see the photograph) was retrieved during the second servicing mission and returned to Earth for ground testing and evaluation. Also retrieved was a Teflon FEP radiator surface from a cryogen vent cover that was exposed to the space environment on the aft bulkhead of the HST. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included determining the FEP degradation mechanisms. As part of the investigations into the degradation mechanisms, specimens retrieved from the first and second HST servicing missions, 3.6 and 6.8 years after launch, respectively, were characterized through exhaustive mechanical, optical, and chemical testing. Testing led by Goddard included scanning electron microscopy, optical microscopy, tensile testing, solar absorptance measurements, time-of-flight secondary ion mass spectroscopy (TOF-SIMS), Fourier transform infrared microscopy (m-FTIR), attenuated total reflectance infrared microscopy (ATR/FTIR), and x-ray diffraction (XRD). The NASA Lewis Research Center contributed significantly to the analysis of the retrieved HST materials by leading efforts and providing results of bend testing, surface microhardness measurements, x-ray photoelectron spectroscopy, solid-state nuclear magnetic resonance spectroscopy, and density measurements. Other testing was conducted by Nano Instruments, Inc., and the University of Akron.

Dever, Joyce A.↗

New optical scheme for a polarimetric-based glucose sensor

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Evaluation Studies↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Achieving Zero Stress in Iridium, Chromium, and Nickel Thin Films

We examine a method for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight x-ray space telescopes into the regime of sub-arc second resolution that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure, including the existence of a critical pressure that results in zero film stress. This critical pressure scales linearly with the film's density. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we have discovered a similar behavior for iridium. Additionally, we have identified zero stress in iridium shortly after island coalescence. This feature of film growth is used for achieving a total internal stress of -2.89 MPa for a 15.8 nm thick iridium film. The surface roughness of this low-stress film was examined using scanning probe microscopy (SPM) and x-ray reflectivity (XRR) at CuKα and these results presented and discussed.

X-ray↗

Robust Extraction and Multi-Technique Analysis of Micrometeoroids Captured in Low Earth Orbit

The use of low-density silica aerogel as the primary capture cell technology for the NASA Discovery mission Stardust to Comet Wild-2 [1] is a strong motivation for researchers within the Meteoritics community to develop techniques to handle this material. The unique properties of silica aerogel allow dust particles to be captured at hypervelocity speeds and to remain partially intact. The same unique properties present difficulties in the preparation of particles for analysis. Using tools borrowed from microbiologists, we have developed techniques for robustly extracting captured hypervelocity dust particles and their residues from aerogel collectors[2-3]. It is important not only to refine these extraction techniques but also to develop protocols for analyzing the captured particles. Since Stardust does not return material to Earth until 2006, researchers must either analyze particles that are impacted in the laboratory using light-gasgun facilities [e.g. 41 or examine aerogel collectors that have been exposed in low-Earth orbit (LEO) [5]. While there are certainly benefits in laboratory shots, i.e. accelerating known compositions of projectiles into aerogel, the LEO capture particles offer the opportunity to investigate real particles captured under real conditions. The aerogel collectors used in this research are part of the NASA Orbital Debris Collection Experiment that was exposed on the MIR Space Station for 18 months [5]. We have developed the capability at the UCB Space Sciences Laboratory to extract tiny volumes of aerogel that completely contain each impact event, and to mount them on micromachined fixtures so that they can be analyzed with no interfering support (Fig.1). These aerogel keystones simultaneously bring the terminal particle and the particle track to within 10 m (15 g cm- ) of the nearest aerogel surface. The extracted aerogel wedges containing both the impact tracks and the captured particles have been characterized using the synchrotron total external reflection X-ray fluorescence (TXRF) microprobe at SSRL, the Nuclear Microprobe at LLNL, synchrotron infrared microscopy at the ALS facility at LBL and the NSLS at BNL, and the Total Reflection X-ray Fluorescence (TXRF) facility at SLAC.

Westphal, A. J.↗